1-20 of 198 Search Results for

medium-frequency direct current system

Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Series: ASM Technical Books
Publisher: ASM International
Published: 01 June 1988
DOI: 10.31399/asm.tb.eihdca.t65220047
EISBN: 978-1-62708-341-6
... are given for low-to-medium-frequency versus RF generators, equivalent ratings for the two types of systems are usually obtained by multiplying the quoted output power for low-to-medium-frequency units by a factor of approximately 0.65 to 0.70. Fig. 4.2 Calorimeter used to determine the power output...
Book Chapter

Series: ASM Technical Books
Publisher: ASM International
Published: 01 August 2015
DOI: 10.31399/asm.tb.piht2.t55050057
EISBN: 978-1-62708-311-9
... quenches and are also used for scanning. Examples of these coils are shown in: Figure 4.10 : Single-turn coil with rigid construction, as commonly used for medium and low frequency, that was designed for annealing a welded tube. The same coil design could be used for heating any round shape, gear...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 March 2006
DOI: 10.31399/asm.tb.pht2.t51440159
EISBN: 978-1-62708-262-4
... is not being heated; the motor generator uses a significant amount of power when not heating a workpiece. Medium-frequency power supplies using solid-state frequency conversions make up the vast majority of induction heating power supplies in use today. These systems have largely replaced motor-generator...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 April 2013
DOI: 10.31399/asm.tb.imub.t53720321
EISBN: 978-1-62708-305-8
... The ultrasonic incident angle can be optimized according to material dimensions. Water, the coupling medium, is always kept in full quantity even in high speed rotation. Thus, the system has the stable mechanism to provide constant detection. One advantage of this system is that linear defects can...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 August 2015
DOI: 10.31399/asm.tb.piht2.t55050025
EISBN: 978-1-62708-311-9
... current-carrying capabilities. In the medium frequencies IGBTs are used, and in the higher frequencies MOS FETs are used. In the future, as the current-carrying ability of transistors is increased and the cost is decreased, transistors are expected to come into wider use over the full frequency range...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 June 1988
DOI: 10.31399/asm.tb.eihdca.t65220185
EISBN: 978-1-62708-341-6
... to that of the induction generator. However, these occasions are considerably fewer at the lower frequencies. In a practical sense, coils of this nature are generally purchased as part of an over-all system, with total responsibility for operation resting with the system supplier. Medium-to-High-Frequency Coils...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 April 2013
DOI: 10.31399/asm.tb.imub.t53720183
EISBN: 978-1-62708-305-8
... as small sources of light in an otherwise dark area. Sensitivity levels of fluorescent penetrants are: ultra-low (Level ½), low (Level 1), medium (Level 3), high (Level 4), and ultrahigh (Level 5). Visible penetrant inspection uses a penetrant that is usually red in color and produces vivid red...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 August 2012
DOI: 10.31399/asm.tb.smfpa.t53500301
EISBN: 978-1-62708-317-1
... the workpiece. Sound waves travel through a medium (solid, liquid, or gas) at a specific speed in a predictable direction. When these sound waves enter a boundary with a different medium, some of the sound waves are reflected back ( Ref 15.21 ). Using standard tests, the standard reference attenuation and echo...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 April 2013
DOI: 10.31399/asm.tb.imub.t53720001
EISBN: 978-1-62708-305-8
... Eddy current Magnetic particle Liquid penetrant Capital cost Medium to high High Low to medium Medium Low Consumable cost Very low High Low Medium Medium Time of results Immediate Delayed Immediate Short delay Short delay Effect of geometry Important Important...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 August 2015
DOI: 10.31399/asm.tb.piht2.t55050001
EISBN: 978-1-62708-311-9
... into medium-frequency induction heating. Because of their higher efficiency and increased versatility as the reliability of the solid-state power supplies increased, solid-state power supplies started to replace motor-generator sets in the 1970s. The continued development trend of solid-state power supplies...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 November 2011
DOI: 10.31399/asm.tb.jub.t53290079
EISBN: 978-1-62708-306-5
..., or aluminum. Also used are medium-carbon steel, lead-free brass and copper, Inconel, titanium, René 41, zirconium, gold, silver, and platinum. 4.5 High-Frequency Welding High-frequency welding includes a number of processes in which metal-to-metal bonding is accomplished by using heat caused...
Book Chapter

Series: ASM Technical Books
Publisher: ASM International
Published: 01 April 2013
DOI: 10.31399/asm.tb.imub.t53720267
EISBN: 978-1-62708-305-8
... in a given medium undergo mode conversion at a boundary, resulting in simultaneous propagation of longitudinal and transverse (shear) waves in a second medium. If the angle is increased, the direction of the refracted longitudinal wave will approach the plane of the boundary (α 2 → 90°). At some specific...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 June 1988
DOI: 10.31399/asm.tb.eihdca.t65220241
EISBN: 978-1-62708-341-6
..., and (2) ferrites or powdered iron combinations for higher frequencies, including those in the radio-frequency (RF) range. The laminations for low- and medium-frequency concentrators are usually of the same grain-oriented silicon steel used for high efficiency in power transformers and electric motors...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 June 1988
DOI: 10.31399/asm.tb.eihdca.t65220085
EISBN: 978-1-62708-341-6
... that required if a solenoid coil is employed. The ability to use a much lower frequency impacts heating costs in two ways. First, the higher-frequency (RF) power supply that would be needed to provide 250,000-Hz power is considerably more expensive on a per-kilowatt basis than the medium-frequency unit...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 August 2015
DOI: 10.31399/asm.tb.piht2.t55050317
EISBN: 978-1-62708-311-9
... from surface of the coil and will leave the surface with a bright finish. Coil Materials Coils are made from copper because of its low resistance to the flow of the high-frequency current and its relatively low price. Coils made from tubing and many of the low- and medium-power coils are made...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 September 2005
DOI: 10.31399/asm.tb.gmpm.t51250249
EISBN: 978-1-62708-345-4
... (below 20 diametral pitch, DP) generally require inductors powered by medium-frequency motor generator sets or solid-state units. Finer-pitch gearing uses encircling coils with power provided by high-frequency vacuum tube units. Wide-faced gearing is heated by scanning-type equipment, while more limited...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 August 2015
DOI: 10.31399/asm.tb.piht2.t55050245
EISBN: 978-1-62708-311-9
... of various nondestructive testing methods Test method Ultrasonics x-ray Eddy current Magnetic particle Liquid penetrant Capital cost Medium to high High Low to medium Medium Low Consumable cost Very low High Low Medium Medium Time of results Immediate Delayed Immediate...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 December 2003
DOI: 10.31399/asm.tb.cfap.t69780164
EISBN: 978-1-62708-281-5
... electrode configuration is measured with a sample material as a dielectric, and then the capacitance of vacuum (or air for most practical purposes), C v , of the same electrode configuration is measured as the dielectric medium. The dielectric constant, κ′, is then computed from Eq 1 : (Eq 1) κ...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 June 1988
DOI: 10.31399/asm.tb.eihdca.t65220143
EISBN: 978-1-62708-341-6
... Thermocouples in RF Induction Heating Applications Unsheathed thermocouples are used for measuring temperatures in low- and medium-frequency induction heating jobs. Fields are rarely induced in either thermocouple or extension wires because the wire diameters are generally very small. With high-frequency...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 June 1988
DOI: 10.31399/asm.tb.eihdca.t65220281
EISBN: 978-1-62708-341-6
... polyester film coating. This four-part disk is inserted in the product cap. The container is filled, and the cap is tightened. The capped container is then passed through a medium- or high-frequency induction field ( Fig. 11.14 ). The field penetrates the cap and heats only the outer edge of the foil...