1-20 of 317 Search Results for

in-line process monitoring

Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Series: ASM Technical Books
Publisher: ASM International
Published: 01 August 2015
DOI: 10.31399/asm.tb.piht2.t55050025
EISBN: 978-1-62708-311-9
... the electrical components, power supply, heat station, work-handling fixture, controls, work coil, and quench system. Depending on the power supply and processing requirements, these elements may be furnished either separately or unitized. The power supply is the component that receives the line power from...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 December 2015
DOI: 10.31399/asm.tb.cpi2.t55030349
EISBN: 978-1-62708-282-2
... the pipeline. Strategic locations are most efficiently identified through an initial ICDA study. On-line, real-time corrosion monitoring data coupled with key pipeline process and environment data can assist the pipeline operator in understanding how corrosion changes with time and variation in pipeline...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 December 2006
DOI: 10.31399/asm.tb.ex2.t69980551
EISBN: 978-1-62708-342-3
... execution to plan, and prepares an annual report on the results and actions. On one hand, the integration of the line managers as trained auditors is supported by the increased demand for internal/external customer orientation and, on the other, is upheld by the ongoing improvement process. In addition...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 December 2006
DOI: 10.31399/asm.tb.cw.t51820203
EISBN: 978-1-62708-339-3
... (HAZ). In some alloys, the HAZ becomes sensitized to severe intergranular (sometimes called knife-line) attack, and in certain other alloys, the HAZ is anodic to the parent metal. When possible, it is more realistic to remove welded coupons from production-sized weldments than to weld the small coupons...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 January 2000
DOI: 10.31399/asm.tb.cub.t66910331
EISBN: 978-1-62708-250-1
... thickness, and 23.27 for tantalum-lined steel. Installed costs of corrosion-resistant 150 mm (6 in.) outside diameter (OD) piping are given in Table 4 and Fig. 4 . The piping system used to generate the data was a 124 m (406 ft) long process piping arrangement typical of those found in a chemical...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 December 2015
DOI: 10.31399/asm.tb.cpi2.t55030292
EISBN: 978-1-62708-282-2
... by the combination of moisture, sulfur components, and oxygen when process equipment is opened to air. Typical applications include linings and tray components in fractionation towers; piping; heat-exchanger tubes; reactor cladding; tubes and tube hangers in furnaces; various components for compressors, turbines...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 July 1997
DOI: 10.31399/asm.tb.wip.t65930085
EISBN: 978-1-62708-359-1
... and eddy-current testing). The nature of the flaw can be more easily assessed from images than from signals. However, interpreting images is not always straightforward. Penetrant tests, for example, indicate flaws that are a result of a blotting action. This can have the effect of forming a line...
Book Chapter

Series: ASM Technical Books
Publisher: ASM International
Published: 01 August 2015
DOI: 10.31399/asm.tb.piht2.t55050293
EISBN: 978-1-62708-311-9
... problem Preventive maintenance (PM) Line water is too hot Outside temperature is too hot for tower Be able to add city water if necessary Tower fan has failed Power supply water too hot Line water to heat exchanger is too hot Monitor line water temperature. Heat exchanger is fouled...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 August 2012
DOI: 10.31399/asm.tb.smfpa.t53500301
EISBN: 978-1-62708-317-1
... transformer is the most commonly used sensor for measuring displacement. Linear Variable Differential Transformers Linear variable differential transformers (LVDTs) are electromechanical transducers that convert the straight-line motion of an object into an electrical signal. The LVDTs are usually...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 December 2015
DOI: 10.31399/asm.tb.cpi2.t55030209
EISBN: 978-1-62708-282-2
.... Traditionally, crude unit overhead neutralizers and filmers are added via dilution streams that are injected into the horizontal section of the overhead vapor line; however, many variations exist. Details of refinery inhibitor injections are difficult to generalize due to the uniqueness and variety of each...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 January 2022
DOI: 10.31399/asm.tb.isceg.t59320323
EISBN: 978-1-62708-332-4
... Return sand temperature fluctuation Return sand temperature Moisture addition impacted Sand cooler adjustment Moisture addition reset Breakdown of one line Sand circulation affected Return sand temperature Sand cooler adjusts Captive casting operations run one or two jobs per day...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 January 2000
DOI: 10.31399/asm.tb.cub.t66910427
EISBN: 978-1-62708-250-1
... the system and inspected periodically to determine the effectiveness of the inhibitor treatment. On-line corrosion sensors and monitors can report the status of corrosion control and warn of a change in conditions that can be detrimental to equipment and facilities. In other cases, the corrosion sensors can...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 December 2015
DOI: 10.31399/asm.tb.cpi2.t55030247
EISBN: 978-1-62708-282-2
.... Erosion of oil and gas gathering lines at bends and joints or in flow-control valves and wellhead equipment by produced sand is probably the other most common occurrence of erosion in oil and gas production. Erosion-Corrosion Strictly speaking, in erosion-corrosion, only the protective corrosion...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 December 1995
DOI: 10.31399/asm.tb.sch6.t68200220
EISBN: 978-1-62708-354-6
... that is being used by steel foundries to improve quality by improving the process is the use of designed experiment techniques. Rather than making changes to the process in an intuitive, on line way, this method allows changes to be tested off line in a planned, statistically valid way. Several variables can...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 December 2015
DOI: 10.31399/asm.tb.cpi2.t55030360
EISBN: 978-1-62708-282-2
... be investigated to confirm that they are in the coating and not in the parent material (possible hydrogen damage) and to ascertain the condition of the material surface beneath them. Any internal corrosion-monitoring features such as corrosion coupons or metallic lining tags Internal bladders...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 August 1999
DOI: 10.31399/asm.tb.caaa.t67870191
EISBN: 978-1-62708-299-0
... and procedures are necessary, and total design should incorporate these wherever possible. In critical areas, design for on-line monitoring and inspection will also be important. The human factor in such procedures is often overlooked. The need for better techniques, standardization, and mechanization or full...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 August 2015
DOI: 10.31399/asm.tb.piht2.t55050245
EISBN: 978-1-62708-311-9
... parts. Table 12.7 lists some of these applications of eddy-current testing. Table 12.8 lists some of the possible hardening errors that the equipment is capable of monitoring during induction heating. In-line processing requires the development of application-specific, eddy-current coils...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 December 2003
DOI: 10.31399/asm.tb.pnfn.t65900231
EISBN: 978-1-62708-350-8
... Shafts treated by the oxynitride process (right) and untreated (left). Both subjected to salt spray test. Courtesy of Plateg GmbH Fig. 1 Internally heated salt bath furnace with immersed alloy electrodes and ceramic tile lining Fig. 2 Internally heated salt bath furnace with submerged...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 March 2006
DOI: 10.31399/asm.tb.pht2.t51440243
EISBN: 978-1-62708-262-4
... computer program for data representation and plotting is highly recommended. If the data do not plot as a straight line indicating a normal distribution, a metallurgical or process-related reason for this “skewness” should be apparent or be determined. An example of a capability study of an atmosphere...
Book Chapter

Series: ASM Technical Books
Publisher: ASM International
Published: 01 June 1988
DOI: 10.31399/asm.tb.eihdca.t65220315
EISBN: 978-1-62708-341-6
... allowable constraints. In addition, the lack of undesirable heating of the surroundings simplifies integration directly into a production line without the need to employ off-line heat processing. This in turn greatly reduces handling costs. Moreover, quality-control and inspection techniques may...