1-20 of 74

Search Results for coal-fired power plants

Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Series: ASM Technical Books
Publisher: ASM International
Published: 01 December 2018
DOI: 10.31399/asm.tb.fibtca.t52430147
EISBN: 978-1-62708-253-2
... Abstract This chapter provides an outline of the failure modes and mechanisms associated with most boiler tube failures in coal-fired power plants. Primary categories include stress rupture failures, water-side corrosion, fire-side corrosion, fire-side erosion, fatigue, operation failures...
Image
Published: 01 December 1989
Fig. 1.4. Schematic diagram of a coal-fired steam power plant ( Ref 4 ). More
Series: ASM Technical Books
Publisher: ASM International
Published: 01 December 2018
DOI: 10.31399/asm.tb.fibtca.t52430017
EISBN: 978-1-62708-253-2
... (IEO 2016) report, there will be continued increase in total coal-fired electricity generation worldwide from 8.6 trillion kilowatt hours in 2012 to 9.7 trillion kilowatt hours in 2020 and 10.6 trillion kilowatt hours by 2040 ( Ref 2.1 ). Coal-based thermal power plants therefore still have a major...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 December 1989
DOI: 10.31399/asm.tb.dmlahtc.t60490383
EISBN: 978-1-62708-340-9
... in significant cost savings in terms of reduced fuel costs and reduced need for added capacity. The historical developments leading to the current need for improved coal-fired power plants have been reviewed by Armor ( Ref 1 ). Two of the important parameters that have been identified and which also have major...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 December 2018
DOI: 10.31399/asm.tb.fibtca.t52430001
EISBN: 978-1-62708-253-2
... specified, a power plant based on coal-fired boilers belongs to the category of subcritical boilers. 1.4.1 Conventional or Subcritical Boilers Conversion of water to steam involves transition from a liquid to a gaseous state; this is associated with a substantial increase in volume. The volume of one...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 December 2018
DOI: 10.31399/asm.tb.fibtca.t52430087
EISBN: 978-1-62708-253-2
... above 580 °C, and therefore, austenitic stainless steels were used in power plants designed in the 1950s ( Ref 4.4 ). In a coal-fired thermal power plant, austenitic stainless steels are used for SH/RH tubing whose main function is to provide heat transfer between the hot flue gases and the high...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 December 2018
DOI: 10.31399/asm.tb.fibtca.t52430409
EISBN: 978-1-62708-253-2
... life assessment secondary superheater tube 8.1 Introduction A large number of coal-fired power plants are currently in operation worldwide and some are older than 30 years. One of the global problems faced by the power sector is the aging of its power plants, including aging of high-pressure...
Book Chapter

Series: ASM Technical Books
Publisher: ASM International
Published: 01 December 2018
DOI: 10.31399/asm.tb.fibtca.t52430314
EISBN: 978-1-62708-253-2
... to furnace gases containing fly ash, 100× Coal used in coal-based thermal power plants mostly comprises combustible and noncombustible mineral constituents, normally known as ash. For example, the coal used in Indian power plants contains a substantially large amount of ash, as much as 45–50%. Indian...
Book Chapter

Series: ASM Technical Books
Publisher: ASM International
Published: 01 November 2007
DOI: 10.31399/asm.tb.htcma.t52080259
EISBN: 978-1-62708-304-1
... furnaces erosion-corrosion fluidized-bed boilers furnace waterwalls thermal fatigue cracking 10.1 Introduction A coal-fired electric power generating station is a highly complex plant. A major piece of the equipment in the power plant is the boiler, which generates steam that is then delivered...
Book Chapter

Series: ASM Technical Books
Publisher: ASM International
Published: 01 December 2018
DOI: 10.31399/asm.tb.fibtca.t52430290
EISBN: 978-1-62708-253-2
... Corrosion In a thermal power plant, the residue arising out of the combustion of solid or liquid fuel is normally termed ash . Ash formed through combustion of coal, named coal ash , contains elements including iron, aluminum, silicon, and calcium along with magnesium, sodium, and potassium...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 December 2018
DOI: 10.31399/asm.tb.fibtca.9781627082532
EISBN: 978-1-62708-253-2
Series: ASM Technical Books
Publisher: ASM International
Published: 01 December 1989
DOI: 10.31399/asm.tb.dmlahtc.9781627083409
EISBN: 978-1-62708-340-9
Series: ASM Technical Books
Publisher: ASM International
Published: 01 December 1989
DOI: 10.31399/asm.tb.dmlahtc.t60490001
EISBN: 978-1-62708-340-9
.... = pulverized coal. S.G.D. = secondary gas desulfurization. A.F.B.C. = atmospheric fluidized-bed combustion. P.F.B.C. = pressurized fluidized-bed combustion. Historical Evolution of Fossil Plants The historical evolution of fossil-fired steam power plants is shown in Fig. 1.3 ( Ref 4...
Series: ASM Technical Books
Publisher: ASM International
Published: 30 June 2023
DOI: 10.31399/asm.tb.atia.t59340303
EISBN: 978-1-62708-427-7
... the value of lightweight aluminum cars, especially for coal-fired power plants. They are dedicated to one route—mine to power plant—enhancing efficiency and lowering costs. The U.S. Department of Energy credits the use of aluminum freight cars for a measurable decrease in total CO 2 emissions produced...
Book Chapter

Series: ASM Technical Books
Publisher: ASM International
Published: 01 November 2007
DOI: 10.31399/asm.tb.htcma.t52080437
EISBN: 978-1-62708-304-1
..., hydrogen atoms can be absorbed at the surface and then diffuse into the metal. Hydrogen atoms in the metal then react with iron carbide forming methane gas which can accumulate at grain boundaries and other interfaces. The chapter describes two applications, one in coal-fired boilers, the other...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 December 1989
DOI: 10.31399/asm.tb.dmlahtc.t60490183
EISBN: 978-1-62708-340-9
... tubing ( Ref 1 ) Stress-rupture Short-term overheating High-temperature creep Dissimilar-metal welds Water-side corrosion Caustic corrosion Hydrogen damage Pitting (localized corrosion) Stress-corrosion cracking Fire-side corrosion Low temperature Waterwall Coal...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 May 2018
DOI: 10.31399/asm.tb.hma.t59250013
EISBN: 978-1-62708-287-7
.... Quoting from Robert B. Gordon in his book American Iron , “Ironmasters using anthracite fuel reduced the labor cost for smelting to $2.50 per ton at a time when the proprietors of the Hopewell charcoal-fired furnace paid wages amounting to $15.14 per ton,” ( Ref 2 ). With the use of anthracite coal...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 November 2007
DOI: 10.31399/asm.tb.htcma.t52080235
EISBN: 978-1-62708-304-1
... particle-laden gas stream ( Ref 1 , 2 ), with average tube skin temperatures varying from 800 to 1120 °C (1475 to 2050 °F) and gas velocities greater than 200 m/s (656 ft/s). In coal-fired boilers, it is well known that fly-ash erosion can be a serious problem for boiler tubes. When coal (which...
Series: ASM Technical Books
Publisher: ASM International
Published: 01 November 2007
DOI: 10.31399/asm.tb.htcma.t52080321
EISBN: 978-1-62708-304-1
... in German Fossil-Fuel Fired Power Plants: Appearance, Mechanism and Causes , Werkst. Korros. , Vol 39 , 1988 , p 54 10.1002/maco.19880390205 13. French D.N. , Metallurgical Failures in Fossil Fired Boilers , 2nd ed. , John Wiley & Sons , 1993 , p 370 14. Welding Services...
Series: ASM Technical Books
Publisher: ASM International
Published: 30 June 2023
DOI: 10.31399/asm.tb.atia.t59340453
EISBN: 978-1-62708-427-7
... on coal-fired power plants and moved as much as possible to renewable energy sources, particularly hydro. Unfortunately, the biggest increase in primary aluminum production has been in China, fueled by coal-powered stations, the worst-possible environmental scenario ( Fig. 20.1 ). In 2018...