ASM Failure Analysis Case Histories: Construction, Mining, and Agricultural Equipment
Fatigue Failure of Crane Clevis Bracket
-
Published:2019
Abstract
The fracture of a clevis which formed part of the derricking gear of a large crane showed well developed conchoidal markings. These were associated with a principal origin on the outer surface at about the mid-width of the section. A number of secondary origins were apparent along this same edge. Failure was initiated at the extrados which suggested that a discrepancy in the size of the pin may have contributed to failure. Microscopic examination of a section through the main origin did not reveal any material defects or the presence of weld repairs which could have led to the...