Handbook of Case Histories in Failure Analysis
Hydrogen Embrittlement of P-110 Couplings for Mating 180 mm (7 in.) Casing in Oilfield Production
-
Published:1992
Abstract
Several tin plated, low-alloy steel couplings designed to connect sections of 180 mm (7 in.) diam casing for application in a gas well fractured under normal operating conditions. The couplings were purchased to American Petroleum Institute (API) specifications for P-110 material. Chemical analysis and mechanical testing of the failed couplings showed that they had been manufactured to the API specification for Q-125, more stringent specification than P-110, and met all requirements of the application. Fractographic examination showed that the point of initiation was an embrittled region approximately 25 mm (1 in.) from the end of the coupling. The source...
Sign in
ASM members
Member Sign InClifford W. Peterson, James Day, Hydrogen Embrittlement of P-110 Couplings for Mating 180 mm (7 in.) Casing in Oilfield Production, Handbook of Case Histories in Failure Analysis, Vol 1, Edited By Khlefa A. Esaklul, ASM International, 1992, p 396–400, https://doi.org/10.31399/asm.fach.v01.c9001117
Download citation file: