Handbook of Case Histories in Failure Analysis
Stress-Corrosion Cracking of a Swaged Stainless Steel Reheater Pendent Tube
-
Published:1993
Abstract
A cold-formed Grade TP 304 stainless steel swaged region of a reheater tube in service for about 8000 hours cracked because of sulfur-induced stress-corrosion cracking (SCC). Cracking initiated from the external surface and a high sulfur content was detected in the outer diameter and crack deposits. Comparison of the microstructure and hardness of the swaged region and unswaged Grade TP 304 stainless steel tube metal indicated that the swaged section was not annealed to reduce the effects of cold working. The high hardness created during swaging increased the stainless steel's susceptibility to sulfur-induced SCC. Because SCC requires water to...
Sign in
ASM members
Member Sign InAnthony C. Studer, Robert S. Dickens, Stress-Corrosion Cracking of a Swaged Stainless Steel Reheater Pendent Tube, Handbook of Case Histories in Failure Analysis, Vol 2, Edited By Khlefa A. Esaklul, ASM International, 1993, p 230–234, https://doi.org/10.31399/asm.fach.v02.c9001345
Download citation file:
Join ASM International
Being a member of the world’s largest association of materials professionals provides the benefits and resources you need to accomplish your personal and professional goals.