Skip Nav Destination
Close Modal
Update search
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
NARROW
Format
Topics
Subjects
Article Type
Volume Subject Area
Date
Availability
1-5 of 5
Steve K. Hsiung
Close
Follow your search
Access your saved searches in your account
Would you like to receive an alert when new items match your search?
Sort by
Proceedings Papers
ISTFA2007, ISTFA 2007: Conference Proceedings from the 33rd International Symposium for Testing and Failure Analysis, 140-145, November 4–8, 2007,
Abstract
View Paper
PDF
Packages with the Modified Daisy-chain (MDC) die have been used increasingly to accelerate reliability stress testing of IC packaging during package development, qualification, and evaluation and reliability monitor programs [1]. Utilizing this approach in essence eliminates chip circuit failure mechanisms. Unlike packages with active die, in packages with the MDC die, when short occurred between two daisy-chain pairs of I/Os, there are four possibilities that can attribute to each pin of the two daisy-chain pairs. That makes the isolation of short failure difficult. Time Domain Reflectometry (TDR) is a well-described technique to characterize package discontinuity (open or short failure). By using a bare package substrate and a reference device, an analyst can characterize the discontinuity and localize it: within the package, the die-package interconnects, or on the die [2]. Scanning SQUID (Superconducting Quantum Interference Device) Microscopy, known as SSM, is a non-destructive technique that detects magnetic fields generated by current. The magnetic field, when converted to current density via Fast Fourier Transform (FFT), is particularly useful to detect shorts and high resistance (HR) defects [3]. In this paper, a new methodology that combines Resistance Analysis, TDR Isolation and SSM Identification for electrical debugging short in packages with the MDC die will be presented. Case studies will also be discussed.
Proceedings Papers
ISTFA2006, ISTFA 2006: Conference Proceedings from the 32nd International Symposium for Testing and Failure Analysis, 163-166, November 12–16, 2006,
Abstract
View Paper
PDF
Failure analysis laser inspection tool (FA/LIT) is a tool for the analysis of packaged devices. FA/LIT can routinely expose bond wires for inspection; however, concerns develop for the exposure of stitch bonds, the examination of small trace cracks, and any requirements to maintain electrical functionality of devices. Matching the FA/LIT settings based upon operation and sample material is critical in achieving good exposure of areas of interest with minimal damage. The use of practice samples, or areas away from the area of interest, to verify results before operations on actual FA parts is strongly recommended in this article. The installation of a grounded sample holder has been shown to greatly improve electrical integrity of samples during the laser ablation procedure. Use of the grounding sample holder improved electrical test results from 0% pass to 100% pass in advanced CMOS devices.
Proceedings Papers
ISTFA2005, ISTFA 2005: Conference Proceedings from the 31st International Symposium for Testing and Failure Analysis, 475-478, November 6–10, 2005,
Abstract
View Paper
PDF
Driven by ever increasing pin-counts and device performance, analyses of multi-layer package substrate failures are increasingly challenging. The tried method of global deprocessing delivers diminishing returns. Increasingly, an entire suite of specialized package analysis tools is needed to complement each other and achieve root-cause.
Proceedings Papers
ISTFA2004, ISTFA 2004: Conference Proceedings from the 30th International Symposium for Testing and Failure Analysis, 73-81, November 14–18, 2004,
Abstract
View Paper
PDF
Scanning SQUID (Superconducting Quantum Interference Device) Microscopy, known as SSM, is a non-destructive technique that detects magnetic fields in Integrated Circuits (IC). The magnetic field, when converted to current density via Fast Fourier Transform (FFT), is particularly useful to detect shorts and high resistance (HR) defects. A short between two wires or layers will cause the current to diverge from the path the designer intended. An analyst can see where the current is not matching the design, thereby easily localizing the fault. Many defects occur between or under metal layers that make it impossible using visible light or infrared emission detecting equipment to locate the defect. SSM is the only tool that can detect signals from defects under metal layers, since magnetic fields are not affected by them. New analysis software makes it possible for the analyst to overlay design layouts, such as CAD Knights, directly onto the current paths found by the SSM. In this paper, we present four case studies where SSM successfully localized short faults in advanced wire-bond and flip-chip packages after other fault analysis methods failed to locate the defects.
Proceedings Papers
ISTFA2001, ISTFA 2001: Conference Proceedings from the 27th International Symposium for Testing and Failure Analysis, 243-250, November 11–15, 2001,
Abstract
View Paper
PDF
Two novel techniques to identify continuity failures in multi-layer substrates of flip-chip package are discussed. The first technique uses the custom designed and fabricated Package Substrate Probe Fixture (PSPF™). The fixture eliminates the traditional method of soldering directly to the package solder balls. This ensures that failures are not heat cured and the solder ball as well as the Ball Grid Array (BGA) pad are not detached from the package substrate during physical analysis. Also employed are beam-based systems that include both Focused Ion Beam (FIB) and Electron-beam (Ebeam) to detect Capacitive Coupling Voltage Contrast (CCVC) images. Voltage contrast imaging augments traditional optical inspection techniques using bright and dark field microscopy.