Skip Nav Destination
Close Modal
Update search
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
NARROW
Format
Topics
Subjects
Article Type
Volume Subject Area
Date
Availability
1-5 of 5
Shuqing Duan
Close
Follow your search
Access your saved searches in your account
Would you like to receive an alert when new items match your search?
Sort by
Proceedings Papers
ISTFA2014, ISTFA 2014: Conference Proceedings from the 40th International Symposium for Testing and Failure Analysis, 420-424, November 9–13, 2014,
Abstract
View Papertitled, Productive Polishing TEM Sample Preparation Methodology Development
View
PDF
for content titled, Productive Polishing TEM Sample Preparation Methodology Development
In this paper, three productive polishing transmission electron microscopy (TEM) sample preparation methods are reported. The methods are studied to improve the efficiency and expand the application fields. Method 1 and 2 address expanding conventional polishing method application on same or similar pattern samples. Method 1 used a laser mark to identify one of the sample; and method 2 used a Pt coated glass inserted between samples or a direct deposition of Pt on one of the samples. Method 3 was developed facilitate stacking three or more samples into a single, batch process block and improved the efficiency greatly.
Proceedings Papers
ISTFA2014, ISTFA 2014: Conference Proceedings from the 40th International Symposium for Testing and Failure Analysis, 425-429, November 9–13, 2014,
Abstract
View Papertitled, Optimization of TEM Sample Preparation to Reduce the Overlapping of TEM Images
View
PDF
for content titled, Optimization of TEM Sample Preparation to Reduce the Overlapping of TEM Images
This paper reports optimized Transmission Electron Microscopy (TEM) sample preparation methods with Focus Ion Beam (FIB), which are used to reduce or avoid the overlapping of TEM images. Several examples of optimized cross-section sample preparation on 38nm and 45nm pitch are provided with general and novel FIB methods. And its application to plan view TEM sample preparation is also shown. The results establish that the proposed method is useful to reduce or remove pattern overlapping effects in dense structures and can produce higher quality TEM images than can be obtained using conventional top-down FIB-based TEM preparation methods.
Proceedings Papers
ISTFA2014, ISTFA 2014: Conference Proceedings from the 40th International Symposium for Testing and Failure Analysis, 462-468, November 9–13, 2014,
Abstract
View Papertitled, A Novel Method for the Specified Site Planar View TEM Sample Preparation
View
PDF
for content titled, A Novel Method for the Specified Site Planar View TEM Sample Preparation
This paper reports a novel method for site specific plan view transmission electron microscopy (TEM) sample preparation. The detailed procedure is introduced step by step. To demonstrate the practicality of this technique in failure analysis, case studies on 45nm and below technology nodes using the novel method are reported. The results showed that the method is very useful for the analysis of the specified failure location and is helpful to improve the success rate of failure analysis.
Proceedings Papers
ISTFA2014, ISTFA 2014: Conference Proceedings from the 40th International Symposium for Testing and Failure Analysis, 515-518, November 9–13, 2014,
Abstract
View Papertitled, TEM Sample Preparation Methods for MEMS Floating Structure Analysis
View
PDF
for content titled, TEM Sample Preparation Methods for MEMS Floating Structure Analysis
The MEMS structure has its particular character like hollow areas inside, and “floating” structures. Traditional TEM sample preparation method usually leads to distortion and dissociation defects of the floating structure. This paper introduces two innovative practical methods of TEM sample preparation using focused ion beam (FIB) for MEMS floating structure analysis. Method 1 used glass needle to lift out the separated film onto glue coated blank wafer; method 2 used in situ pick up system to lift out L- or C-shaped cut film onto TEM half-grid. And then the sample can be applied to normal TEM membrane preparation procedure.
Proceedings Papers
ISTFA2007, ISTFA 2007: Conference Proceedings from the 33rd International Symposium for Testing and Failure Analysis, 121-125, November 4–8, 2007,
Abstract
View Papertitled, Al Pad Corrosion Mechanism Study When Dicing Saw
View
PDF
for content titled, Al Pad Corrosion Mechanism Study When Dicing Saw
The corrosion phenomenon was found at the edge area of bond pad under OM images after dicing saw. Experiment showed that the corrosion was related with the feed speed of dicing saw. From SEM and OM results, there were some abnormal contaminations around the corrosive area. Auger and TEM with EDX system were used to characterize the corrosive region and the related Al pad corrosion mechanism was discussed. In this paper, Cu rich and O rich layers were identified by TEM and EDX, which could be induced by galvanic cell reaction.