Skip Nav Destination
Close Modal
Update search
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
NARROW
Format
Subjects
Article Type
Volume Subject Area
Date
Availability
1-7 of 7
Gyoyoung Jin
Close
Follow your search
Access your saved searches in your account
Would you like to receive an alert when new items match your search?
Sort by
Proceedings Papers
ISTFA2016, ISTFA 2016: Conference Proceedings from the 42nd International Symposium for Testing and Failure Analysis, 82-84, November 6–10, 2016,
Abstract
View Paper
PDF
System failure due to a progressive defect in memory cell-array of DRAM was studied with automated test equipment. In order to find out relationship correctable single-bit fault and system failure, memory cells with single-bit fault by a cross-defect were selected. After high voltage and temperature stress, a soft cross-defect was changed into a hard cross-defect. Consequentially, invalid operation by a degraded cross-defect causes array-failure. Based on the failure analysis, methods to prevent array-failure are proposed, and applied to DRAM successfully.
Proceedings Papers
ISTFA2016, ISTFA 2016: Conference Proceedings from the 42nd International Symposium for Testing and Failure Analysis, 85-87, November 6–10, 2016,
Abstract
View Paper
PDF
Body effect is the key characteristic of DRAM cell transistor. Conventional method uses a TEG structure for body effect measurement. But this measurement is not accurate, because TEG structure has only several transistors and it is located outside of the DRAM die. This paper suggests a viable method for measuring DRAM cell transistor body effect. It uses a memory test system for fast, massive, nondestructive measurement. Newly developed method can measure 100,000 DRAM cell body effects in two minute, without sample damage. The test gives one median value and 100,000 individual values of body effects. Median value of measured body effects is equal to the TEG body effect. An individual DRAM cell body effect has a correlation with the fin height.
Proceedings Papers
ISTFA2016, ISTFA 2016: Conference Proceedings from the 42nd International Symposium for Testing and Failure Analysis, 88-90, November 6–10, 2016,
Abstract
View Paper
PDF
As the DRAM structure is miniaturized, the cell capacitance is reduced and resistance is increased. Because of this change, the DRAM operation is more sensitive than previous generations to changes of the device elements. The device elements consist of cell capacitance, Bit Line (BL) capacitance, cell node resistance, supply-voltage and the surround noise. The elements were changed by decreasing the cell node dimensions. The write time (tWR) is degraded by changing the elements. In particular, the noise is very variable element on change of surrounding cell phase which is data1 or data 0. In this paper, we show that one of the most dominant contributors to failure is the plate noise and explain how plate voltage level affects tWR delay. The effect of the plate voltage modulation can be correlated with ∆Vbl which is bit line level difference to read out the data. We define this phenomenon as the plate dc noise effect and propose a model in miniaturized DRAM.
Proceedings Papers
ISTFA2016, ISTFA 2016: Conference Proceedings from the 42nd International Symposium for Testing and Failure Analysis, 91-93, November 6–10, 2016,
Abstract
View Paper
PDF
Systematic retention failure related on the adjacent electrostatic potential is studied with sub 20nm DRAM. Unlike traditional retention failures which are caused by gate induced drain leakage or junction leakage, this failure is influenced by the combination of adjacent signal line and adjacent contact node voltage. As the critical dimension between adjacent active and the adjacent signal line and contact node is scaled down, the effect of electric field caused by adjacent node on storage node is increased gradually. In this paper, we will show that the relationship between the combination electric field of adjacent nodes and the data retention characteristics and we will demonstrate the mechanism based on the electrical analysis and 3D TCAD simulation simultaneously.
Proceedings Papers
ISTFA2016, ISTFA 2016: Conference Proceedings from the 42nd International Symposium for Testing and Failure Analysis, 94-96, November 6–10, 2016,
Abstract
View Paper
PDF
As microelectronic feature sizes are scaled down, the soft failure rate has increased. Additionally the characteristics and distribution of Dynamic Random Access Memory (DRAM) data retention time and write recovery time (tWR) are getting worse. As a result of this failure analysis, we revealed that the major contributors are caused by the interference noise, resultant from decreasing separation distance between nodes and the signal line noise increasing. This paper gives a detailed analysis of the problem caused by the coupling effects. We investigated the cause of soft noise by simulation and proposed calculation of sensing margin change by interference noise. Finally, we expect that a design improvement to reduce the magnitude of interference noise will result in overall improvement when implemented in the test vehicle.
Proceedings Papers
ISTFA2015, ISTFA 2015: Conference Proceedings from the 41st International Symposium for Testing and Failure Analysis, 234-236, November 1–5, 2015,
Abstract
View Paper
PDF
As microelectronic feature sizes are scaled down, the characteristics and distribution of DRAM data retention time and write recovery time are getting worse. This degradation is due to the increases in the leakage current and resistance of the cell node and the decrease of cell capacitance in DRAM devices. As the physical distance between storage nodes decreases, node potential is increasingly affected by small potential changes in adjacent storage nodes. In this paper, we will show that the one of the most dominant contributors to failure is the adjacent storage node level, and we will demonstrate how node level affects write time delay. The effect of the adjacent storage node level can be correlated with a change in threshold voltage, much like the MOSFET body effect. We define this phenomenon as the lateral body effect, and propose a model for adjacent potential effect using the Buried Cell Array Transistor (BCAT) structure in sub 20nm DRAM.
Proceedings Papers
ISTFA2015, ISTFA 2015: Conference Proceedings from the 41st International Symposium for Testing and Failure Analysis, 237-240, November 1–5, 2015,
Abstract
View Paper
PDF
The open bit line architecture scheme is an effective method to achieve higher density memory devices. With the scaling of DRAM, we have adopted a bit line sense amplifier (BLSA) design using a shared local power line for reducing the circuit layout dimensions. As a result of this new design, the write time of the memory cell was sometimes degraded because of an increase in initial sensing noise. This paper gives a detailed analysis of the problem caused by the initial sensing noise by examination of the behaviour of the opposite data portion of the cell array matrix when the word line is not activated. Finally, we propose a design improvement to reduce the magnitude of noise peaks and the results of this improvement when implemented in the test vehicle.