Skip Nav Destination
Close Modal
Update search
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
NARROW
Format
Topics
Subjects
Article Type
Volume Subject Area
Date
Availability
1-1 of 1
D. Park
Close
Follow your search
Access your saved searches in your account
Would you like to receive an alert when new items match your search?
Sort by
Proceedings Papers
ITSC 2010, Thermal Spray 2010: Proceedings from the International Thermal Spray Conference, 780-785, May 3–5, 2010,
Abstract
View Paper
PDF
Cu 54 Zr 22 Ti 18 Ni 6 amorphous powders were deposited onto aluminum substrates by cold spray process with different powder preheating temperature (below T g : 623K, near T g : 703K, and T x : 773K). The microstructure and macroscopic properties of coating layers were investigated using OM, XRD, DSC and hardness, SUGA test, potentio-dynamic corrosion test. XRD results showed that cold sprayed Cu based amorphous coating layers of 300~350 μm thickness could be well manufactured regardless of powder preheating temperature. Porosity measurements revealed that the coating layers of 623K and 773K preheating temperature conditions had lower porosity contents (0.88%, 0.93%) than that of 623K preheating conditions (4.87%). Hardness was measured as 374.8HV (623K), 436.3HV (703K) and 455.4HV (773K) for the coating layers, respectively. Results from the wear resistance examination via SUGA test and those from the hardness testing showed the same trends. Examination of corrosion resistance of the amorphous coating layer showed that the critical anodic current density (ic) of the coating layer, for which powder preheating was provided at 623K and then cold spray deposition, was 5.6X10-3A/cm 2 . The ic values of the 703K and 773K coating layers were 4.8X10 -4 and 1.2X10 -3 A/cm 2 , respectively. Both temperature conditions were found to offer superior corrosion characteristics to those of the 623K-prehaeted and coated specimen. This was assumed to be attributed to the relatively lower level of porosity.