Skip Nav Destination
Close Modal
Update search
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
NARROW
Format
Topics
Subjects
Article Type
Volume Subject Area
Date
Availability
1-1 of 1
C. M. Chan
Close
Follow your search
Access your saved searches in your account
Would you like to receive an alert when new items match your search?
Sort by
Proceedings Papers
ISTFA1999, ISTFA 1999: Conference Proceedings from the 25th International Symposium for Testing and Failure Analysis, 293-296, November 14–18, 1999,
Abstract
View Paper
PDF
Several hundred units were subjected to autoclave stress as part of the qualification of a new fast static RAM. Many units failed after autoclave stress, and these parts recovered after conventional depotting using nitric acid and a hot plate. Based on the recovery of the units, the failures were determined to be fuse-related because the nitric acid cleared the fuse cavities during depotting. Chemical analysis after thermally extracting the die from the package revealed an antimony-rich material in failing fuse cavities. Source of the antimony was linked to antimony trioxide added to the plastic package as a fire retardant. However, it was unclear whether the antimony-rich material caused the failure or if it was an artifact of thermal depotting. A new approach that did not thermally or chemically alter the fuse cavities was employed to identify the failing fuses. This approach used a combination of back-side grinding, dimpling, and back-side microprobing. The antimony-rich material found in the fuse cavity was confirmed using SEM and TEM-based EDS analysis, and it is believed to be a major contributing factor to fuse failures. However, it is unclear whether the short was caused by the antimony-rich material or by a reaction between that material and residual aluminum (oxide) left in the fuse cavity after the laser blows.