Skip Nav Destination
Close Modal
Update search
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
NARROW
Format
Topics
Subjects
Article Type
Volume Subject Area
Date
Availability
1-1 of 1
R. Scarpellini
Close
Follow your search
Access your saved searches in your account
Would you like to receive an alert when new items match your search?
Sort by
Proceedings Papers
ITSC2000, Thermal Spray 2000: Proceedings from the International Thermal Spray Conference, 1319-1323, May 8–11, 2000,
Abstract
PDF
An innovative methodology to deposit, by plasma spraying, ceramic thermal barrier coatings on gas turbine blades and vanes was developed. Such a methodology produces a pattern of microcracks in the coating, thus improving its thermal shock resistance. After a laboratory campaign of process optimization and coating characterization, real components were coated with a 150µm thick layer of NiCoCrAlY as a bond coat and a 300µm thick layer of ZrO2, partially stabilised with 8%of Y2O3, as a top coat. In particular, four vanes, taken from the first stage of a land based gas turbine (V64.3, produced by Ansaldo), were coated on the whole airfoil. The four vanes were submitted to a cyclic oxidation test in a burner rig simulating the operative conditions of a gas turbine. In particular, they were exposed to a gas flow with the same composition, temperature and speed of the inlet gas of a real gas turbine; moreover, they were cooled by an internal stream of compressed air for obtaining the same temperature profile of a vane in operation. The surface temperature of the vanes was monitored during the test by an optical pyrometer and the internal temperature by a thermocouple. After 550 hours of test, corresponding to 550 cycles, the four vanes did not show any sign of damage.