Abstract
In this investigation, particle image velocimetry (PIV) and direct imaging are used to measure particle velocities during cold spraying. Four feedstock powders were sprayed, including Ni, WC-Co, carbonyl Fe, and Cr steel. Multiple exposures at 500 ns intervals were used to measure in-flight particle velocities via direct imaging with a high shutter speed camera. Velocimetry measurements were made with a double-pulse laser and a high-resolution camera. With the minimum frame straddling time set to 100 ns, a maximum particle velocity of 1052 m/s was measured.
This content is only available as a PDF.
Copyright © 2014 DVS Media GmbH. All rights reserved.
2014
DVS Media GmbH
Issue Section:
Process Diagnostics, Sensors, and Controls
You do not currently have access to this content.