Skip Nav Destination
Close Modal
Update search
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
NARROW
Format
Subjects
Article Type
Volume Subject Area
Date
Availability
1-1 of 1
Shou-Ming Huang
Close
Follow your search
Access your saved searches in your account
Would you like to receive an alert when new items match your search?
Sort by
Proceedings Papers
ISTFA2017, ISTFA 2017: Conference Proceedings from the 43rd International Symposium for Testing and Failure Analysis, 50-53, November 5–9, 2017,
Abstract
View Paper
PDF
In this article, we demonstrate using lock-in thermography (LIT) to perform fault isolation of leakage on a board-mounted device with rough, heterogeneous epoxy encapsulation. It is interesting to observe LIT spot shifting either on the failing unit’s reference pin or the failed pin using a different lock-in frequency. The protection diode of the reference pin is triggered by LIT and the electrical behavior should not be affected by varying lock-in frequencies (0.1 Hz to 25 Hz). The reason for the shifting hot spot is a non-uniform morphology in the epoxy encapsulation, which consists of different thicknesses and voids. This complicated epoxy encapsulation morphology results in a non-uniform heat conduction pathway when a different lock-in frequency is used. In this study, a LIT hot spot will stabilize and remain in a fixed position when the lock-in frequency is increased to greater than 5 Hz and the phase shift is directly proportional to the square-root of the lock-in frequency. This indicates that the heat conduction becomes stable under such a condition, and the phase shift value can still be used for relative depth localization. By overlaying LIT and X-ray imaging, an accurate position of the fault location in the X-Y plane can be detected. A quick and non-destructive 3D fault isolation method for complicated system level failure can be achieved in this way.