Skip Nav Destination
Close Modal
Update search
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
NARROW
Format
Topics
Article Type
Volume Subject Area
Date
Availability
1-1 of 1
Minoru Sugawara
Close
Follow your search
Access your saved searches in your account
Would you like to receive an alert when new items match your search?
Sort by
Proceedings Papers
ISTFA2010, ISTFA 2010: Conference Proceedings from the 36th International Symposium for Testing and Failure Analysis, 265-270, November 14–18, 2010,
Abstract
PDF
Abstract We have been paying attention to the development of the nondestructive physical analysis (NDPA) technology. We think that NDPA is a technology which doesn't depend on the worker's capability or experience. There are many NDPA techniques, and analysis using X-ray imaging is one of the principal techniques. Due to the progress of the image analysis using computers in recent years, X-ray imaging have been evolving from two dimensional images to three dimensional imaging. We have been applying X-ray CT imaging to actual failure analysis and reliability evaluation since 2008. At ISTFA 2009, we reported on the effectiveness of X-ray Computed Tomography (CT) images in the failure analysis. [1] We confirmed that the X-ray CT image had various applications, for example, screening for counterfeit parts, the detection of the defect of the multi-layers printed wiring boards (multi-layers PWB), the structure confirmation of caulking contacts, and the detection of cracks or voids of the solder joint. This paper discusses the effectiveness of X-ray CT imaging in failure analysis and discusses the effectiveness of applying X-ray CT imaging to the propagation of cracks occurring at solder joints during temperature cycling test.