Abstract
This paper discusses the failure analysis process of a DC failure using an in-FIB (Focused Ion Beam) nanoprobing technique with four probes and a scanning capacitance microscope (SCM) in advanced DRAM devices. Current-Voltage (I-V) curves measured by the nanoprobing technique indicate the curve of the failed device is different from that of the normal device. The failed device causes a high leakage current in the test. The cross-sectional 2-D doping profile of SCM verifies the region of the P-Well has shifted to create a leakage path that causes this failure.
This content is only available as a PDF.
Copyright © 2007 ASM International. All rights reserved.