Abstract
Electrical failures due to front-end defectivity may be detected in-line using large area PVC inspection. Application of this method to a self-aligned contact module of a memory chip is presented. Most of the defectivity affecting this module is non-visual. The PVC inspection results allow representative defects to be cross-sectioned and fully characterized soon after they are created. This approach to FA offers much faster results and much larger sampling of the defectivity affecting each lot than end of line FA. Current experiments to debug the principal defect types are described.
This content is only available as a PDF.
Copyright © 2002 ASM International. All rights reserved.
2002
ASM International
Issue Section:
Yield Enhancement
You do not currently have access to this content.