1-20 of 223

Search Results for water-recirculating systems

Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Image
Published: 09 June 2014
Fig. 1 (a) Water recirculating system for cooling an induction power supply including stainless steel pump, copper pipe, cartridge filter, nonferrous plate-type heat exchanger, and temperature control to prevent condensation. (b) Schematic of closed-loop water cooling system in (a) More
Series: ASM Handbook
Volume: 13A
Publisher: ASM International
Published: 01 January 2003
DOI: 10.31399/asm.hb.v13a.a0003701
EISBN: 978-1-62708-182-5
... pretreatment methods of the incoming water and preboiler corrosion protection methods. It analyzes internal treatment and condensate treatment of boilers. The article discusses three types of cooling systems: once-through systems, open recirculating systems, and closed recirculating systems. The corrosion...
Book Chapter

By Fred R. Specht
Series: ASM Handbook
Volume: 4C
Publisher: ASM International
Published: 09 June 2014
DOI: 10.31399/asm.hb.v04c.a0005851
EISBN: 978-1-62708-167-2
... Abstract Cooling towers are designed to remove heat from water in an induction system and dissipate it into the atmosphere. This article provides information on closed-loop recirculating water systems of an induction system to cool the power supply. It focuses on various types of cooling towers...
Image
Published: 01 January 1994
Fig. 6 Cathodic electrodeposition coating system. (1) Load area. (2) Conveyor. (3) Pretreatment. (4) Deionized water rinse. (5) Electrodeposition tank. (6) Recirculated permeate rinse. (7) Fresh permeate rinse. (8) Deionized water rinse. (9) Dryoff. (10) Curing oven. (11) Deionized quench More
Image
Published: 01 January 2006
Fig. 3 A closed loop service water system typical for plants using sea water as the prime coolant. As the service loop is a closed-recirculating system, little make-up water is needed. More
Image
Published: 01 January 2006
Fig. 1 Typical arrangement where raw water is used in service water system and as makeup to the cooling tower. Because the condenser loop is an open-recirculating system, make-up water is needed to replace evaporation and blowdown. More
Series: ASM Handbook
Volume: 13C
Publisher: ASM International
Published: 01 January 2006
DOI: 10.31399/asm.hb.v13c.a0004102
EISBN: 978-1-62708-184-9
... tower. Two typical designs are shown in Fig. 1 and Fig. 2 . There are numerous variations on these designs. Fig. 1 Typical arrangement where raw water is used in service water system and as makeup to the cooling tower. Because the condenser loop is an open-recirculating system, make-up water...
Book Chapter

By Richard E. Haimbaugh
Series: ASM Handbook
Volume: 4B
Publisher: ASM International
Published: 30 September 2014
DOI: 10.31399/asm.hb.v04b.a0005924
EISBN: 978-1-62708-166-5
... recirculation systems later in this article. Galvanic corrosion: This is another cause of fitting deterioration and water contamination. Care must be taken in the connection of systems not to place dissimilar metals in contact with each other without the use of a galvanic fitting. For example, if the heat...
Series: ASM Handbook
Volume: 4C
Publisher: ASM International
Published: 09 June 2014
DOI: 10.31399/asm.hb.v04c.a0005850
EISBN: 978-1-62708-167-2
.... Every three months, check the conductivity of the recirculating water with a handheld conductivity meter. When the conductivity reaches the threshold recommended by the OEM, then it is time to drain and refill, then drain again and refill the system. See the OEM manual for recommended cleaning flushing...
Series: ASM Handbook
Volume: 13C
Publisher: ASM International
Published: 01 January 2006
DOI: 10.31399/asm.hb.v13c.a0004145
EISBN: 978-1-62708-184-9
... structures (e.g., condensers, steam turbines, feedwater heaters, etc.) is covered in the Section “Corrosion in Fossil and Alternative Fuel Industries.” Background to Problem Most currently operating BWRs are direct-cycle systems. That is, water boils in traversing the fuel channels in the core...
Series: ASM Handbook
Volume: 13C
Publisher: ASM International
Published: 01 January 2006
DOI: 10.31399/asm.hb.v13c.a0004146
EISBN: 978-1-62708-184-9
... those of BWRs. A schematic diagram of a typical PWR is shown in Fig. 1 . Fig. 1 Basic flow diagram of a pressurized water reactor (PWR) nuclear power station Materials Used In the PWR, a high pressure of the order of 14 MPa (∼2250 psi) is applied to the primary system to prevent...
Series: ASM Handbook
Volume: 5
Publisher: ASM International
Published: 01 January 1994
DOI: 10.31399/asm.hb.v05.a0001324
EISBN: 978-1-62708-170-2
... as costly to use as TCE and PCE, and eventually they will be unavailable for use. The primary alternatives to ODC and VOC materials are aqueous degreasing systems. Because the components are solids and soluble in water, compliance with the Clean Air Act can be easily achieved. It is compliance...
Book Chapter

By E. Bud Senkowski
Series: ASM Handbook
Volume: 5B
Publisher: ASM International
Published: 30 September 2015
DOI: 10.31399/asm.hb.v05b.a0006035
EISBN: 978-1-62708-172-6
... 37,981 408,821 Vogtle PWR 59,094 636,084 South Texas PWR 59,129 636,461 BWR, boiling water reactor; PWR, pressurized water reactor Classification of Nuclear Coating Systems Coating systems within a nuclear generating plant are classified according to performance requirements...
Series: ASM Handbook
Volume: 13C
Publisher: ASM International
Published: 01 January 2006
DOI: 10.31399/asm.hb.v13c.a0004147
EISBN: 978-1-62708-184-9
... 2 and H 2 , with O 2 forming primarily from the oxidation of H 2 O 2 and HO 2 with an OH radical, and from the thermal decomposition of H 2 O 2 . Because H 2 partitions to the steam phase and H 2 O 2 is not volatile, approximately 87% of the water that is recirculated in a BWR (approximately...
Book Chapter

By William R. Tyrrell
Book: Machining
Series: ASM Handbook
Volume: 16
Publisher: ASM International
Published: 01 January 1989
DOI: 10.31399/asm.hb.v16.a0002159
EISBN: 978-1-62708-188-7
... Diamond tools used in rotary ultrasonic machining A water jacket is positioned at the bottom of the spindle and immediately above the tool. Water from a recirculating pump system or the main water supply is fed through the water jacket, into the center of the rotating spindle, and down through...
Book Chapter

By Steven M. Nourie
Series: ASM Handbook
Volume: 5
Publisher: ASM International
Published: 01 January 1994
DOI: 10.31399/asm.hb.v05.a0001224
EISBN: 978-1-62708-170-2
... layer into the water-rich lower layer, permitting both cleaning phases to come in contact with the surfaces to be cleaned. When used in a spray system, a diphase cleaner resembles an unstable single phase cleaner, because the solvent and water phases are mixed in the pumping action. An emulsifiable...
Book Chapter

By J.L. Dossett
Series: ASM Handbook
Volume: 4B
Publisher: ASM International
Published: 30 September 2014
DOI: 10.31399/asm.hb.v04b.a0005943
EISBN: 978-1-62708-166-5
... that was cooled using shell and tube heat exchangers (as was the polymer quenchant) with water from a large, 19,000 L (5000 gal), treated water system. This system was in turn kept cool by two evaporative cooling towers. There were two continuous tempering furnaces in the induction area geared for a two-hour...
Book Chapter

By William J. Gilbert
Series: ASM Handbook
Volume: 13C
Publisher: ASM International
Published: 01 January 2006
DOI: 10.31399/asm.hb.v13c.a0004137
EISBN: 978-1-62708-184-9
...), a packed tower absorber, exhaust fan, ducting, liquid piping, and liquid recirculation pumps. Figure 2 shows a standard system arrangement, and installed equipment is shown in Fig. 3 . Fig. 2 Schematic of a general scrubber system arrangement Fig. 3 A stainless steel venturi tube...
Book Chapter

By Jeffrey P. Gossner, Kenneth B. Tator
Series: ASM Handbook
Volume: 5
Publisher: ASM International
Published: 01 January 1994
DOI: 10.31399/asm.hb.v05.a0001277
EISBN: 978-1-62708-170-2
... hazards by collecting overspray in water. However, water-wash spray booths are usually more costly to install, operate, and maintain than dry booths. Some localities prohibit discharging spray booth water into sewers, and adequate recirculation systems and controls must be installed. Spray booths...
Book Chapter

By Stanley Zinn
Series: ASM Handbook
Volume: 4C
Publisher: ASM International
Published: 09 June 2014
DOI: 10.31399/asm.hb.v04c.a0005862
EISBN: 978-1-62708-167-2
..., effective additives are salt (sodium and calcium chloride) and caustic (sodium and potassium hydroxide), both of which increase the uniformity of the water quench without detracting from its cooling power. However, these additives in themselves create drawbacks including requiring a closed system...