Published: 01 January 1994
Fig. 11 Indirect-fired continuous convection oven for curing of paint coatings. (a) Exhaust system. (b) Burner and recirculating fan More
Series: ASM Handbook
Volume: 4C
Publisher: ASM International
Published: 09 June 2014
DOI: 10.31399/asm.hb.v04c.a0005851
EISBN: 978-1-62708-167-2
...-loop nonferrous recirculating system to cool the power supply, heat station, coils, bus, and water-cooled leads/cables. All use some sort of water-to-water heat exchanger in conjunction with plant water (dirty water) supplied by a cooling tower, radiator/fan, refrigeration-type chillers, city water...
Series: ASM Handbook
Volume: 4C
Publisher: ASM International
Published: 09 June 2014
DOI: 10.31399/asm.hb.v04c.a0005850
EISBN: 978-1-62708-167-2
... operation. Do not get water on vital components; control boards should be cleaned with an electrical cleaner if excessive dirt is present. A clean dry paintbrush works well to remove dirt from fragile components. Clean dirt in any air recirculating fans. Yearly, change any air filters and confirm...
Series: ASM Handbook
Volume: 4B
Publisher: ASM International
Published: 30 September 2014
DOI: 10.31399/asm.hb.v04b.a0005931
EISBN: 978-1-62708-166-5
... recirculation fans HEAT TREATING FURNACES require several different control systems and integration for optimum technical results and safe operation. Most modern heat treating control systems are equipped with dedicated process controller(s) linked with programmable logic controllers (PLCs) or personal...
Series: ASM Handbook
Volume: 22B
Publisher: ASM International
Published: 01 November 2010
DOI: 10.31399/asm.hb.v22b.a0005529
EISBN: 978-1-62708-197-9
... chamber, and fans are used for recirculating the atmosphere. Heating Elements The heating elements can be classified according to their heating methods: direct fired, radiant tube, and electrical. Direct-Fired Heating Parts are exposed directly to the products of combustion, typically gas...
Series: ASM Handbook
Volume: 13C
Publisher: ASM International
Published: 01 January 2006
DOI: 10.31399/asm.hb.v13c.a0004137
EISBN: 978-1-62708-184-9
...), a packed tower absorber, exhaust fan, ducting, liquid piping, and liquid recirculation pumps. Figure 2 shows a standard system arrangement, and installed equipment is shown in Fig. 3 . Fig. 2 Schematic of a general scrubber system arrangement Fig. 3 A stainless steel venturi tube...
Series: ASM Handbook
Volume: 4B
Publisher: ASM International
Published: 30 September 2014
DOI: 10.31399/asm.hb.v04b.a0005957
EISBN: 978-1-62708-166-5
... heating either with a fan underneath the roof or with one external to the furnace for recirculation. Box ovens are made of continuously welded plate steel and heavy structural steel members. The wall and roof are insulted by layered ceramic-fiber blanket with a low thermal mass. The door uses edge...
Series: ASM Handbook
Volume: 4B
Publisher: ASM International
Published: 30 September 2014
DOI: 10.31399/asm.hb.v04b.a0005943
EISBN: 978-1-62708-166-5
... total throughput time cycle, two batch tempering furnaces, and a parts washer. Aluminum Processes There was one large gas-fired, recirculating air furnace (certified) served by a manipulator for handling up to 1360 kg (3000 lb) loads of aluminum. After solution treating by quenching in a 19,000 L...
Series: ASM Handbook
Volume: 4B
Publisher: ASM International
Published: 30 September 2014
DOI: 10.31399/asm.hb.v04b.a0005955
EISBN: 978-1-62708-166-5
... pumping system Generally, a gas cooling or quenching system Instrumentation to monitor and display critical processing data A wide variety of processing requirements can be accommodated by changing the chamber length or by adding internal doors, circulating fans, recirculating gas systems...
Series: ASM Handbook
Volume: 5B
Publisher: ASM International
Published: 30 September 2015
DOI: 10.31399/asm.hb.v05b.a0006035
EISBN: 978-1-62708-172-6
... support steel … • Reactor coolant pumps and motors … • Equipment supports • • Pressure relief tank … • Accumulator tanks … • Valves, hangars, and piping • • Fan coil cooling units … • Polar crane … • Electrical and equipment boxes • • Suppression chamber...
Series: ASM Handbook
Volume: 13C
Publisher: ASM International
Published: 01 January 2006
DOI: 10.31399/asm.hb.v13c.a0004164
EISBN: 978-1-62708-184-9
... for heat exchangers (radiators and heater cores) or new engine/motor designs (fuel cell technology or heavy-duty engines with new exhaust gas recirculation (ERG) systems), will require engine coolant technology to continue to change to keep up with these improvements. Cooling System Functions...
Book Chapter

Series: ASM Desk Editions
Publisher: ASM International
Published: 01 November 1995
DOI: 10.31399/asm.hb.emde.a0003017
EISBN: 978-1-62708-200-6
... with the continued rotation of the molds to prevent the molten plastic from slumping. Cooling is generally accomplished by air cooling with a high-velocity fan and then water cooling with a fine spray over the mold. Other means of cooling that produce similar results can be used. After the mold and plastic part...
Series: ASM Handbook
Volume: 7
Publisher: ASM International
Published: 30 September 2015
DOI: 10.31399/asm.hb.v07.a0006065
EISBN: 978-1-62708-175-7
... the atomizing nozzle and the cyclones, the airborne concentration of aluminum powder is kept to a level below which forms an explosive mixture (lower explosive limit, LEL). Airflow in the system is created by means of an eductor, so that powder does not have to travel through a rotating fan, which eliminates...
Series: ASM Handbook
Volume: 5
Publisher: ASM International
Published: 01 January 1994
DOI: 10.31399/asm.hb.v05.a0001228
EISBN: 978-1-62708-170-2
... are too large to be placed in blasting machines, portable equipment, such as air blast equipment, can be brought to the workpiece. A low-cost sand usually is used, because it is difficult to reclaim or recirculate the abrasive with portable equipment. Also, it is necessary to prevent random scatter...
Series: ASM Handbook
Volume: 4D
Publisher: ASM International
Published: 01 October 2014
DOI: 10.31399/asm.hb.v04d.a0005973
EISBN: 978-1-62708-168-9
..., hardenability, and complexity of shape, the following methods are used to obtain increasingly accelerated cooling of nominally air-hardening steels: Cool in still air or nitrogen—that is, atmospheric air or nitrogen undisturbed by artificial circulation Cool in fan air or nitrogen—that is, a current...
Series: ASM Handbook
Volume: 5
Publisher: ASM International
Published: 01 January 1994
DOI: 10.31399/asm.hb.v05.a0001277
EISBN: 978-1-62708-170-2
... solids content. Heating units are available in two basic types, recirculating and nonrecirculating. Recirculating heating units circulate heated paint between the heater and spray gun, maintaining a constant temperature. Nonrecirculating units heat the paint only once. After the paint passes through...
Series: ASM Handbook
Volume: 4B
Publisher: ASM International
Published: 30 September 2014
DOI: 10.31399/asm.hb.v04b.a0005930
EISBN: 978-1-62708-166-5
... surface that is in contact with the furnace refractory. The furnace components that suffer metal dusting include furnace fan shafts, thermowells, probes, and anchors. Metal dusting has been encountered with straight chromium steels, austenitic stainless steels, and nickel- and cobalt-base alloys. All...
Series: ASM Handbook
Volume: 5A
Publisher: ASM International
Published: 01 August 2013
DOI: 10.31399/asm.hb.v05a.a0005759
EISBN: 978-1-62708-171-9
... powder/dust leakage. Penetrations through typical panels are required to be lined such that hoses and cables are not exposed to sharp edges. Booth Ceilings/Roofs Often the ceiling or roof area of a thermal spray booth is used as a location for the mounting of equipment such as fans, power sources...
Book: Casting
Series: ASM Handbook
Volume: 15
Publisher: ASM International
Published: 01 December 2008
DOI: 10.31399/asm.hb.v15.a0009020
EISBN: 978-1-62708-187-0
..., the temperature in an engine compartment may be as low as −40 °C (−40 °F) when starting a vehicle that has been parked outside in the cold winters of Manitoba, Canada. During operation a few minutes later, exhaust components, such as the catalytic converter and exhaust gas recirculation tube (EMF), may reach...
Series: ASM Handbook
Volume: 18
Publisher: ASM International
Published: 31 December 2017
DOI: 10.31399/asm.hb.v18.a0006429
EISBN: 978-1-62708-192-4
.... Pumps ( Ref 3 ) are primarily used for liquid, except for a vacuum pump to deal with negative air pressure. Compressors ( Ref 4 ) as well as blowers and fans are devices for pressurized gas only, which are categorized by the pressure level. Pumps and compressors are similar devices in terms of treatment...