Skip Nav Destination
Close Modal
By
Kenneth B. Tator, William R. Slama
By
Ashok Kumar, L.D. Stephenson, Robert H. Heidersbach
By
Bill Corbett
By
R.A. Nixon
By
E. Bud Senkowski, Kenneth B. Tator
By
S.R. Freeman
By
R.A. Nixon
By
David C. Silverman
Search Results for
protective lining
Update search
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
NARROW
Format
Topics
Book Series
Date
Availability
1-20 of 1418
Search Results for protective lining
Follow your search
Access your saved searches in your account
Would you like to receive an alert when new items match your search?
1
Sort by
Book Chapter
Chemical-Setting Ceramic Linings
Available to PurchaseSeries: ASM Handbook
Volume: 13A
Publisher: ASM International
Published: 01 January 2003
DOI: 10.31399/asm.hb.v13a.a0003684
EISBN: 978-1-62708-182-5
... Abstract Inorganic chemical-setting ceramic linings are one of the most widely used construction materials in designing the protective linings for industrial installations. Monolithic linings can be applied by cast or gunite (shotcreting) methods over steel or concrete as well as brick...
Abstract
Inorganic chemical-setting ceramic linings are one of the most widely used construction materials in designing the protective linings for industrial installations. Monolithic linings can be applied by cast or gunite (shotcreting) methods over steel or concrete as well as brick and mortar masonry. This article provides a discussion on the function of monolithic linings, the advantages of these materials, the types of applications in which these materials can be successfully used, and the limitations of these linings. It describes the application procedures that should be followed to ensure proper installation of a dual-lining system. The industrial applications that illustrate the corrosion resistance and some uses of monolithic linings, as well as other applications in wastewater treatment systems and the chemical industry, are discussed.
Image
Magnesium anode used to cathodically protect glass-lined steel water heater...
Available to PurchasePublished: 01 January 2003
Series: ASM Handbook
Volume: 13A
Publisher: ASM International
Published: 01 January 2003
DOI: 10.31399/asm.hb.v13a.a0003608
EISBN: 978-1-62708-182-5
... that is cathodically protected, if a foreign pipeline crosses or passes close to the protected pipeline, current from the cathodic protection system can gather onto the foreign pipeline and then be discharged from the foreign line when it crosses or comes close to the protected pipeline. This is particularly true...
Abstract
Stray-current corrosion is an accelerated form of corrosion caused by externally induced electric current. It can occur in unprotected pipelines and submerged metal structures located near electric power sources or anywhere voltage differences exist. This article describes common scenarios and sources of stray current along with ways to detect it and prevent the type of corrosion it can cause.
Series: ASM Handbook
Volume: 5B
Publisher: ASM International
Published: 30 September 2015
DOI: 10.31399/asm.hb.v05b.a0006047
EISBN: 978-1-62708-172-6
... Abstract Two-component polyurea elastomeric coating/lining systems are the newest technology in the protective coating/lining industry and a wide variety of applications have been developed. These include coating/lining applications over concrete, geotextile membranes, various metals...
Abstract
Two-component polyurea elastomeric coating/lining systems are the newest technology in the protective coating/lining industry and a wide variety of applications have been developed. These include coating/lining applications over concrete, geotextile membranes, various metals for corrosion and decorative areas, and some plastics. This article discusses the formulation basics of polyurea technology and compares the technology to that of polyurethane and polyurethane/polyurea systems. It addresses performance issues and describes application processing considerations and safety practices of polyurea coating/lining systems.
Book Chapter
Polyester and Vinyl Ester Coatings
Available to PurchaseSeries: ASM Handbook
Volume: 5B
Publisher: ASM International
Published: 30 September 2015
DOI: 10.31399/asm.hb.v05b.a0006009
EISBN: 978-1-62708-172-6
... and vinyl ester coatings, namely, curing systems, thixotropic agents and fillers. It exemplifies polyester and vinyl ester coating, lining and flooring systems that are used for top-to-bottom protection of industrial plants and equipment. The article also highlights the concerns to be addressed when using...
Abstract
This article provides a discussion on polyester coating applications such as powder coatings, can coatings, and automotive paints. It includes an overview, structure, properties, and benefits of vinyl ester resins. The article discusses the additives for both unsaturated polyester and vinyl ester coatings, namely, curing systems, thixotropic agents and fillers. It exemplifies polyester and vinyl ester coating, lining and flooring systems that are used for top-to-bottom protection of industrial plants and equipment. The article also highlights the concerns to be addressed when using polyesters and vinyl esters.
Series: ASM Handbook
Volume: 5B
Publisher: ASM International
Published: 30 September 2015
DOI: 10.31399/asm.hb.v05b.a0006027
EISBN: 978-1-62708-172-6
... Abstract This article provides a brief discussion on the common types of overlayers that can be used on a metal surface to protect it from corrosion. These overlayers include phosphate, chromate, and chromate-free conversion coatings; hot dip galvanizing; cementitious linings; glass...
Abstract
This article provides a brief discussion on the common types of overlayers that can be used on a metal surface to protect it from corrosion. These overlayers include phosphate, chromate, and chromate-free conversion coatings; hot dip galvanizing; cementitious linings; glass and porcelain enamels; electroplating; thermal spray coatings; and rubber linings.
Book Chapter
Corrosion Control for Military Facilities
Available to PurchaseSeries: ASM Handbook
Volume: 13C
Publisher: ASM International
Published: 01 January 2006
DOI: 10.31399/asm.hb.v13c.a0004121
EISBN: 978-1-62708-184-9
.... These include protective coatings and linings, cathodic protection, advanced materials selection and design, water treatment, equipment inspection and monitoring, and below-grade moisture mitigation. cathodic protection corrosion control corrosivity equipment inspection advanced materials selection...
Abstract
The major benefit of the implementation of the corrosion-control technologies at Army installations is the extension of the service life of buildings and other structures. This article reviews the exposure of military facilities and equipment to a wide variety of environmental conditions, including soils, waters, or atmospheres of varying corrosivity. It presents the case studies illustrating typical examples of the types of corrosion problems found on military installations. The article describes the various corrosion-control technologies used in military facilities. These include protective coatings and linings, cathodic protection, advanced materials selection and design, water treatment, equipment inspection and monitoring, and below-grade moisture mitigation.
Series: ASM Handbook
Volume: 13C
Publisher: ASM International
Published: 01 January 2006
DOI: 10.31399/asm.hb.v13c.a0004210
EISBN: 978-1-62708-184-9
... and gas gathering lines at bends and joints or in flow-control valves and wellhead equipment by produced sand is probably the other most common occurrence of erosion in oil and gas production. Erosion-Corrosion Strictly speaking, in erosion-corrosion, only the protective corrosion product film...
Abstract
This article discusses the particular corrosion problems encountered and the corrosion control methods used in petroleum production (i.e., upstream) and the storage and transportation of oil and gas (i.e., midstream) up to the refinery (i.e., downstream). These control methods include proper material selection, protective coatings, cathodic protection systems, use of inhibitors, use of nonmetallic materials, and control of the environment. The article reviews the aspects of corrosion that tend to be unique to corrosion as encountered in applications involving oil and gas exploration and production. It discusses corrosion problems that are specific to the various types of environments or equipment used in secondary recovery, including producing wells, producing flow lines, and injection wells. Corrosion mitigation methods and guidelines are also discussed for each type of environment.
Series: ASM Handbook
Volume: 5B
Publisher: ASM International
Published: 30 September 2015
DOI: 10.31399/asm.hb.v05b.a0006035
EISBN: 978-1-62708-172-6
... the following tests that replicate immersion conditions on installed linings: ASTM D6943, “Standard Practice for Immersion Testing of Industrial Protective Coatings” ( Ref 6 ) NACE TM0174-2002, “Laboratory Methods for the Evaluation of Protective Coatings and Lining Materials on Metallic Substrates...
Abstract
Surface coatings are essential in all facilities that process nuclear materials or use nuclear fission for power generation. This article describes the coatings used in two basic types of Generation 3 nuclear reactor designs in the United States and their containment size. These reactors are the boiling water reactor (BWR) and pressurized water reactor (PWR). The article provides information on the loss-of-coolant accident (LOCA) identified as the design basis accident (DBA), which can rapidly de-water the core of an operating nuclear reactor. To avoid LOCA, both the BWR and the PWR include emergency core cooling systems. The article describes a DBA test and other coating performance parameters necessary for safety-related coating systems. It provides a detailed account of the selection criteria of coating types in a nuclear plant. The article concludes by highlighting protective coating strategies in Generation 3 Plants.
Book Chapter
Shop and Field Quality Control and Quality Assurance
Available to PurchaseSeries: ASM Handbook
Volume: 5B
Publisher: ASM International
Published: 30 September 2015
DOI: 10.31399/asm.hb.v05b.a0006016
EISBN: 978-1-62708-172-6
... and installation of the protective coating/lining system. Prior to beginning surface-preparation operations, many specifications will require a presurface-preparation inspection to verify the correction of fabrication defects and removal of surface contamination such as grease, oil, cutting compounds, lubricants...
Abstract
This article discusses the concepts of quality control (QC) and quality assurance (QA), and clarifies the differences and similarities in the roles and responsibilities of QC and QA personnel. It describes the inspection procedures used to verify proper surface preparation and installation of the protective coating/lining system. Prior to beginning surface-preparation operations, many specifications will require a presurface-preparation inspection to verify the correction of fabrication defects and removal of surface contamination such as grease, oil, cutting compounds, lubricants, and chemical contaminants. When inspecting concrete prior to coating installation, three areas of concern exist: surface roughness, moisture content in concrete, and acidity/alkalinity of the surface. The article provides information on the industry standards for assessing surface cleanliness. It details postcoating application quality requirements, including measuring of dry-film thickness, assessing intercoat cleanliness, verifying minimum and maximum recoat intervals, performing holiday/pinhole detection, conducting cure/hardness testing, and assessing adhesion of the applied coating system.
Series: ASM Handbook
Volume: 13A
Publisher: ASM International
Published: 01 January 2003
DOI: 10.31399/asm.hb.v13a.a0003691
EISBN: 978-1-62708-182-5
... of the Environmental Protection Agency and the Occupational Safety and Health Administration as well as the corresponding Code of Federal Regulation numbers. coating lining material surface preparation THE TOTAL NATIONAL YEARLY COST of metallic corrosion in the United States was estimated at $275 billion...
Abstract
This article presents an overview of the different types of coating and lining materials available. It provides information on the various means of surface preparation and the equipment and techniques of coating application. The article discusses the coatings industry's response to the enacted as well as proposed legislation of limiting the use of potentially harmful or toxic raw materials or surface preparation and/or application techniques. The article summarizes the existing federal regulations affecting the coatings industry categorized according to the requirements of the Environmental Protection Agency and the Occupational Safety and Health Administration as well as the corresponding Code of Federal Regulation numbers.
Book Chapter
Protective Coatings for Corrosion Control in Municipal Wastewater Systems
Available to PurchaseSeries: ASM Handbook
Volume: 5B
Publisher: ASM International
Published: 30 September 2015
DOI: 10.31399/asm.hb.v05b.a0006059
EISBN: 978-1-62708-172-6
... or internal protective coatings or linings other than the cement mortar coating or concrete core included in their original manufacture. The ductile iron option (up to 110 cm, or 42 in., in diameter) typically includes internal cement mortar or epoxy linings and external polyethylene encasement for corrosion...
Abstract
This article provides information on the municipal wastewater system components such as piping, pump stations, headworks, clarifiers, aeration structures, digesters, biosolids dewatering equipment, and sludge stabilization. It explains the major corrosion damage mechanisms to which those component parts of the system are exposed. It presents useful guidelines for selecting and using protective coatings in municipal sewerage collection systems and water reclamation facilities in wastewater treatment plants. The article includes annotated flow diagrams of a wastewater collection system, wastewater treatment plants, and spreadsheets listing the most widely used generic coating systems by structure and substrate material. It concludes with a section on quality watchouts when selecting or using protective coatings in municipal wastewater systems.
Book Chapter
Rubber Coatings and Linings
Available to PurchaseSeries: ASM Handbook
Volume: 13A
Publisher: ASM International
Published: 01 January 2003
DOI: 10.31399/asm.hb.v13a.a0003695
EISBN: 978-1-62708-182-5
... as a Protective Lining Since 1839, when Charles Goodyear discovered the process known as vulcanization , whereby a soft, amorphous mass of natural rubber cross-linked into a resilient, elastomeric material with excellent elongation, modulus, and tensile strength, rubber has been used as a material...
Abstract
This article presents a detailed discussion on the relative performance properties of principal rubber types used in lining applications together with their application, vulcanization and inspection techniques, and material and installation costs.
Book Chapter
Analysis and Prevention of Corrosion-Related Failures
Available to PurchaseSeries: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003549
EISBN: 978-1-62708-180-1
... in the environment; change in the alloy or heat treatment; change in design; use of galvanic protection; use of inhibitors; use of nonmetallic coatings and liners; application of metallic coatings; use of surface treatments, thermal spray, or other surface modifications; corrosion monitoring; and preventive...
Abstract
This article provides an overview of the electrochemical nature of corrosion and analyzes corrosion-related failures. It describes corrosion failure analysis and discusses corrective and preventive approaches to mitigate corrosion-related failures of metals. These include: change in the environment; change in the alloy or heat treatment; change in design; use of galvanic protection; use of inhibitors; use of nonmetallic coatings and liners; application of metallic coatings; use of surface treatments, thermal spray, or other surface modifications; corrosion monitoring; and preventive maintenance.
Image
Metal consumption over time for an alloy forming a protective scale under v...
Available to PurchasePublished: 30 August 2021
Fig. 18 Metal consumption over time for an alloy forming a protective scale under various turbine cycling conditions. The solid black line indicates metal consumption in a thermal cycling regime, with each parabola representing oxidation after effective loss of the protective oxide layer
More
Book Chapter
Guidance for the Use of Protective Coatings in Municipal Potable Water Systems
Available to PurchaseSeries: ASM Handbook
Volume: 5B
Publisher: ASM International
Published: 30 September 2015
DOI: 10.31399/asm.hb.v05b.a0006040
EISBN: 978-1-62708-172-6
... for associated pump stations and piping, as discussed subsequently. Earthen-berm reservoirs are typically lined with sheet linings composed of polyethylene or other types of thermoplastic or synthetic rubber to prevent water leakage. Most concrete reservoirs are not coated for corrosion protection, because...
Abstract
This article presents information regarding the use of protective coatings in municipal potable water systems, including raw water collection and transmission, water treatment plants, and treated water distribution. It provides useful guidance for the selection and use of protective coatings in these municipal water systems. The most commonplace corrosion-damage mechanisms are highlighted. The article describes the most common materials of construction found in municipal water systems, namely, cast iron, ductile iron, carbon steel, precast concrete cylinder pipe and reinforced concrete pipe, prestressed concrete tanks, and stainless steel. It provides information on the most common generic coating systems used for new steel tanks and water storage tanks. It concludes with a discussion of quality watch-outs when selecting or using protective coatings in municipal water systems.
Image
Schematic of a chemical-resistant dual-lining system that provides double p...
Available to PurchasePublished: 01 January 2003
Fig. 1 Schematic of a chemical-resistant dual-lining system that provides double protection to the substrate in the form of a flexible membrane and a rigid surface layer. The flexible corrosion-resistant membrane is applied in direct contact with steel or concrete substrates
More
Book: Corrosion: Materials
Series: ASM Handbook
Volume: 13B
Publisher: ASM International
Published: 01 January 2005
DOI: 10.31399/asm.hb.v13b.a0003809
EISBN: 978-1-62708-183-2
... Abstract This article describes the paint systems generally used to protect steel structures, steel sheet, and bridges from corrosion, and how they deter corrosion. It provides a discussion on the basic design criteria of steel structures for corrosion protection. The article also explains...
Abstract
This article describes the paint systems generally used to protect steel structures, steel sheet, and bridges from corrosion, and how they deter corrosion. It provides a discussion on the basic design criteria of steel structures for corrosion protection. The article also explains the differences between prepaint and postpaint, and the steps involved in prepaint processing of steel. It presents the selection guideline for paint system evaluation. The advantages of corrosion protection are also discussed.
Book Chapter
Introduction to Environmental Performance of Nonmetallic Materials
Available to PurchaseBook: Corrosion: Materials
Series: ASM Handbook
Volume: 13B
Publisher: ASM International
Published: 01 January 2005
DOI: 10.31399/asm.hb.v13b.a0003840
EISBN: 978-1-62708-183-2
... and uses of these materials. ceramics organic coatings concrete elastomers nonmetallic materials plastics protective coatings refractories thermosetting resins resin-matrix composites rubber linings WHEN PEOPLE THINK OF CORROSION, they sometimes attribute such degradation to only...
Abstract
This article provides an overview of the environmental performance of the most commonly used nonmetallic materials, including elastomers, plastics, thermosetting resins, resin-matrix composites, organic coatings, concrete, refractories, and ceramics. It also discusses the applications and uses of these materials.
Series: ASM Handbook
Volume: 13C
Publisher: ASM International
Published: 01 January 2006
DOI: 10.31399/asm.hb.v13c.a0004115
EISBN: 978-1-62708-184-9
... to: Cathodic protection (CP) ( Ref 3 , 4 , 5 ) High voltage dc (HVDC) power lines ( Ref 6 ) Transit systems ( Ref 1 , 7 , 8 , 9 ) Direct current operated mining equipment Electric railways Welding, both onshore and offshore ( Ref 10 ) Electroplating or battery-charging equipment...
Abstract
Stray current can be defined as a current in structures that are underground or immersed in an electrolyte that most often accelerate corrosion on a structure where a positive current leaves the structure to enter the earth or an electrolyte. This article provides a description of the principles of stray current and a discussion on the major types of stray current and their properties and prediction methods. It discusses the consequences of stray current and describes the interference tests used for mapping the path of the stray currents. The article also highlights the methods of mitigating the source of stray current.
1