1-20 of 1553

Search Results for metal-line corrosion

Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Series: ASM Handbook
Volume: 13C
Publisher: ASM International
Published: 01 January 2006
DOI: 10.31399/asm.hb.v13c.a0004171
EISBN: 978-1-62708-184-9
... that the factors outside the normal processing of wafers or tool-specific problems can contribute to metal-line corrosion. corrosion semiconductor wafer fabrication batch metal-etch systems single-wafer metal-etch systems metal-line corrosion THE MICROELECTRONICS INDUSTRY is one of the fastest...
Image
Published: 01 January 2006
Fig. 1 Corrosion of the aluminum alloy metal lines on a wafer seen (a) in plan view with a light microscope and (b) in profile with a scanning electron microscope (SEM) More
Series: ASM Handbook
Volume: 13A
Publisher: ASM International
Published: 01 January 2003
DOI: 10.31399/asm.hb.v13a.a0003608
EISBN: 978-1-62708-182-5
... in higher resistivity soil. Accelerated corrosion occurs on the foreign line at the point of current discharge. The location of the discharge can be detected because the pipe-to-soil potential is very low at that point. Likewise in an oil or gas field, where the flowline system or the well casings from...
Series: ASM Handbook
Volume: 13C
Publisher: ASM International
Published: 01 January 2006
DOI: 10.31399/asm.hb.v13c.a0004101
EISBN: 978-1-62708-184-9
... to analyze the causes of corrosion of metals in contact with water. It discusses the Langelier saturation index and the Larson index for determining corrosion in potable water systems. The article describes the two major ways of mitigation against corrosion in potable water systems. The first is to line...
Series: ASM Handbook
Volume: 13A
Publisher: ASM International
Published: 01 January 2003
DOI: 10.31399/asm.hb.v13a.a0003623
EISBN: 978-1-62708-182-5
... patented in 1959. The resultant commercial alloys—Corronel 220 and Hastelloy alloy B-282—were found to be superior to alloy B in resisting knife-line attack but were not immune to it. In fact, it was demonstrated that the addition of 2% V decreased the corrosion resistance of the base metal in HCl...
Series: ASM Handbook
Volume: 5B
Publisher: ASM International
Published: 30 September 2015
DOI: 10.31399/asm.hb.v05b.a0006027
EISBN: 978-1-62708-172-6
... Abstract This article provides a brief discussion on the common types of overlayers that can be used on a metal surface to protect it from corrosion. These overlayers include phosphate, chromate, and chromate-free conversion coatings; hot dip galvanizing; cementitious linings; glass...
Series: ASM Handbook
Volume: 6
Publisher: ASM International
Published: 01 January 1993
DOI: 10.31399/asm.hb.v06.a0001471
EISBN: 978-1-62708-173-3
... region adjacent to the fusion line, known as the unmixed (chilled) region, where the base metal is melted and then quickly solidified to produce a composition similar to the base metal ( Ref 5 ). For example, when type 304 stainless steel is welded using a filler metal with high chromium-nickel content...
Series: ASM Handbook
Volume: 13C
Publisher: ASM International
Published: 01 January 2006
DOI: 10.31399/asm.hb.v13c.a0004181
EISBN: 978-1-62708-184-9
... and glass-lined steel to be essentially nonresistant of fluorides and to know the source and specification limits of the acid if these materials are used. Ferric Salts The presence of Fe 3+ ions in HCl has a profound effect on the corrosion of many metals and alloys otherwise resistant to HCl...
Series: ASM Handbook
Volume: 13C
Publisher: ASM International
Published: 01 January 2006
DOI: 10.31399/asm.hb.v13c.a0004121
EISBN: 978-1-62708-184-9
.... Condensate lines, like most liquid return lines, normally run only partially full, and corrosion occurs if inhibitors do not prevent pH shifts that cause the condensate to become acidic. Leakage of air (oxygen and carbon dioxide) into the return line causes this corrosion. (See the article “Corrosion...
Series: ASM Handbook
Volume: 13C
Publisher: ASM International
Published: 01 January 2006
DOI: 10.31399/asm.hb.v13c.a0004204
EISBN: 978-1-62708-184-9
... describes the three primary causes of failure in the manufacture of pharmaceuticals: embedded iron, failures of glass linings, and corrosion under thermal insulation. fluoropolymers graphite nickel nickel alloys stainless steel thermal insulation titanium zirconium glass-lined steel...
Series: ASM Handbook
Volume: 13C
Publisher: ASM International
Published: 01 January 2006
DOI: 10.31399/asm.hb.v13c.a0004143
EISBN: 978-1-62708-184-9
... assists the cleaning action. During circulation, temperature and chemical concentration are measured to monitor the progress. The cleaner may be replenished (sweetened) occasionally to maintain efficiency. Corrosion coupons or on-line monitoring are sometimes used to evaluate the effect of the cleaning...
Series: ASM Handbook
Volume: 13A
Publisher: ASM International
Published: 01 January 2003
DOI: 10.31399/asm.hb.v13a.a0003661
EISBN: 978-1-62708-182-5
.... “Standard Guide for On-Line Monitoring of Corrosion in Plant Equipment (Electrical and Electrochemical Methods),” G 96, Wear and Erosion; Metal Corrosion , Vol 03.02 , Annual Book of ASTM Standards , American Society for Testing and Materials , 2002 10. Eden D.A. , Electrochemical Noise...
Series: ASM Handbook
Volume: 13C
Publisher: ASM International
Published: 01 January 2006
DOI: 10.31399/asm.hb.v13c.a0004213
EISBN: 978-1-62708-184-9
... with respect to copper sulfate reference electrode (CSE). Source: Ref 11 Surface Films The surface films present on a metal also can alter the corrosion potential and cause differential cell corrosion. For example, mill scale is created on line pipe steel during the manufacturing process (hot...
Series: ASM Handbook
Volume: 5B
Publisher: ASM International
Published: 30 September 2015
DOI: 10.31399/asm.hb.v05b.a0006047
EISBN: 978-1-62708-172-6
... there typically is no premixing or hot potting. Since the introduction of two-component polyurea technology, a wide variety of applications have been developed. These include coating/lining applications over concrete, geotextile membranes, various metals for corrosion and decorative areas, and some plastics...
Series: ASM Handbook
Volume: 13A
Publisher: ASM International
Published: 01 January 2003
DOI: 10.31399/asm.hb.v13a.a0003656
EISBN: 978-1-62708-182-5
... of the technique include its inability to be used on ferromagnetic metals or where ferromagnetic metals are in proximity, such as steel rivets on aluminum, and its inability to be used as a real-time monitor. Conclusions On-line monitoring of localized corrosion is still a challenge to researchers, plant...
Series: ASM Handbook
Volume: 13A
Publisher: ASM International
Published: 01 January 2003
DOI: 10.31399/asm.hb.v13a.a0003583
EISBN: 978-1-62708-182-5
... as a combination of electrochemical reactions is important, because, for aqueous corrosion processes, electrochemical techniques are the predominant methods used in their study to measure rates as well as in the development of on-line sensors. The primary goal of this article is to introduce the electrochemical...
Series: ASM Handbook
Volume: 13A
Publisher: ASM International
Published: 01 January 2003
DOI: 10.31399/asm.hb.v13a.a0003580
EISBN: 978-1-62708-182-5
... -pH conditions below these lines, the metal is stable, and corrosion cannot take place. This is the immunity region ( Fig. 1 ). For E -pH conditions above the line for the equilibrium between the metal and the first metallic ion, the metal is not stable, and it tends to be oxidized and dissolved...
Series: ASM Handbook
Volume: 5B
Publisher: ASM International
Published: 30 September 2015
DOI: 10.31399/asm.hb.v05b.a0006059
EISBN: 978-1-62708-172-6
... in which corrosion protection should be used to prevent acidic attack of concrete and aggressive ferrous metal corrosion. However, most CSO storage tunnels are not lined with liquid-applied organic polymeric coatings. Rather, concrete surfaces in CSO tunnels or collection tanks are unlined or are protected...
Image
Published: 15 January 2021
Fig. 14 (a) Surface view of interdendritic microbiologically influenced corrosion (MIC) attack at the fusion line of a weld in stainless steel; nondendritic at “A” and dendritic at “D.” (b) Cross section of damage associated with MIC showing extensive corrosion of weld metal and fusion line More
Series: ASM Handbook
Volume: 13C
Publisher: ASM International
Published: 01 January 2006
DOI: 10.31399/asm.hb.v13c.a0004214
EISBN: 978-1-62708-184-9
... implemented. New Technology for Real-Time On-Line Monitoring Modern field corrosion monitoring now includes a broad range of techniques used to evaluate the degradation of metallic materials. These techniques can be divided into two distinct groups: namely, those providing indications of the cumulative...