1-20 of 517 Search Results for

display equipment

Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Series: ASM Handbook
Volume: 11
Publisher: ASM International
Published: 15 January 2021
DOI: 10.31399/asm.hb.v11.a0006769
EISBN: 978-1-62708-295-2
... the development of SEM technology and operating principles of basic systems of SEM. The basic systems covered include the electron optical column, signal detection and display equipment, and the vacuum system. The processes involved in the preparation of samples for observation using an SEM are described...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003533
EISBN: 978-1-62708-180-1
... column, signal detection and display equipment, and vacuum system. It discusses the preparation of samples for observation using an SEM and describes the application of SEM in fractography. If the surface remains unaffected and undamaged by events subsequent to the actual failure, it is often a simple...
Series: ASM Handbook
Volume: 17
Publisher: ASM International
Published: 01 August 2018
DOI: 10.31399/asm.hb.v17.a0006469
EISBN: 978-1-62708-190-0
... describes how specific material conditions produce and modify A-scan indications. The article provides information on the controls and their functions for the display unit of the electronic equipment. It describes the techniques used for the identification and characterization of flaws, namely, surface...
Series: ASM Handbook
Volume: 4B
Publisher: ASM International
Published: 30 September 2014
DOI: 10.31399/asm.hb.v04b.a0005931
EISBN: 978-1-62708-166-5
... systems must be able to adjust the flow of gases for process optimization. The operator interface of a furnace-control system displays critical information such as the furnace temperature, atmosphere status, alarms, electronic chart recorders, recipe, and maintenance. A supervisory control and data...
Series: ASM Desk Editions
Publisher: ASM International
Published: 01 November 1995
DOI: 10.31399/asm.hb.emde.a0003067
EISBN: 978-1-62708-200-6
...-resistant applications, lighting, information display, electronic processing and electronic devices, optical and ophthalmic products, and communications equipment. architectural glass biomedical glass dental glass glass fibers lamp glass optical glass specialty glasses traditional glasses...
Book Chapter

Series: ASM Desk Editions
Publisher: ASM International
Published: 01 December 1998
DOI: 10.31399/asm.hb.mhde2.a0003236
EISBN: 978-1-62708-199-3
... methods such as photographs. (Photographic equipment, facsimile recorders, or x - y plotters can be used to record B-scan data for later reference.) Oscilloscope input for one axis of the display is provided by an electromechanical device, which generates an electrical voltage proportional...
Book Chapter

Series: ASM Desk Editions
Publisher: ASM International
Published: 01 December 1998
DOI: 10.31399/asm.hb.mhde2.a0003236
EISBN: 978-1-62708-199-3
... to resort to permanent imaging methods such as photographs. (Photographic equipment, facsimile recorders, or x - y plotters can be used to record B-scan data for later reference.) Oscilloscope input for one axis of the display is provided by an electromechanical device, which generates an electrical...
Series: ASM Handbook
Volume: 4C
Publisher: ASM International
Published: 09 June 2014
DOI: 10.31399/asm.hb.v04c.a0005909
EISBN: 978-1-62708-167-2
..., refractory lining, and measurement and control equipment associated with this technology have continuously been developed and improved. Maintenance must be performed at regularly scheduled intervals to ensure safe operation of furnaces. Any accident could end in production losses, and metal runouts could...
Series: ASM Handbook
Volume: 17
Publisher: ASM International
Published: 01 August 2018
DOI: 10.31399/asm.hb.v17.a0006473
EISBN: 978-1-62708-190-0
... and larger, but the screen will not be flooded with indications of smaller discontinuities that are of no interest. On instruments so equipped, these blocks are used to set the sensitivity-time control or DAC so that a flaw of a given size will produce an indication on the display screen...
Series: ASM Handbook
Volume: 17
Publisher: ASM International
Published: 01 August 2018
DOI: 10.31399/asm.hb.v17.a0006454
EISBN: 978-1-62708-190-0
.... Most NDT inspectors work with resonant sensors and broad statistical aspects of the AE activity and do not need to know the precise details of each source event. They use electronic equipment that measures devised features of the received waveforms and displays results in terms of those features...
Series: ASM Handbook
Volume: 17
Publisher: ASM International
Published: 01 August 2018
DOI: 10.31399/asm.hb.v17.a0006472
EISBN: 978-1-62708-190-0
... mm (20 in.) and the displayed distance being ±1% of the actual distance moved. In addition to the aforementioned requirements, the equipment should be able to select an appropriate portion of the time base within which A-scans are digitized, and it is recommended to use a sampling rate...
Series: ASM Desk Editions
Publisher: ASM International
Published: 01 November 1995
DOI: 10.31399/asm.hb.emde.a0003045
EISBN: 978-1-62708-200-6
... of scans. It reviews the important quality control techniques used during the manufacture of composite components by analyzing tooling control, material control, pattern orientation control, and in-process control. composite components equipment design in-process control material control...
Book: Machining
Series: ASM Handbook
Volume: 16
Publisher: ASM International
Published: 01 January 1989
DOI: 10.31399/asm.hb.v16.a0002176
EISBN: 978-1-62708-188-7
... consist of the hardware and software used to perform the specialized design functions required by a particular customer. The CAD hardware typically includes the computer, one or more graphics display terminals, keyboards, and other peripheral equipment. The CAD software consists of the computer programs...
Book Chapter