1-20 of 447 Search Results for

closed-loop control system

Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Image
Published: 31 October 2011
Fig. 4 An example closed-loop control system employs both a setpoint selector model and a steady-state weld process model. The desired bead width, W Ref , and penetration, P Ref , are specified by the user. These parameters, as well as the workpiece thickness, H , are fed to a setpoint More
Image
Published: 01 January 2006
Fig. 1 Block diagrams of (a) an open-loop control system and (b) a closed-loop or feedback control system More
Image
Published: 31 October 2011
Fig. 1 Block diagram showing a typical modern closed-loop gun control system. EB, electron beam More
Series: ASM Handbook
Volume: 6A
Publisher: ASM International
Published: 31 October 2011
DOI: 10.31399/asm.hb.v06a.a0005553
EISBN: 978-1-62708-174-0
... Abstract This article provides an overview of the methods used to control aspects of the arc welding process and research associated with the development of closed-loop feedback control of the process. Successful implementation of a closed-loop feedback control system requires sensing, modeling...
Series: ASM Handbook
Volume: 14B
Publisher: ASM International
Published: 01 January 2006
DOI: 10.31399/asm.hb.v14b.a0005153
EISBN: 978-1-62708-186-3
... and feedback (or closed-loop) control systems. In open-loop control, the controller sends the actuator a predefined control signal that is not based on the output of the plant. The control signal is computed based on the desired output of the plant and models of the plant and actuator. In other words...
Series: ASM Handbook
Volume: 6A
Publisher: ASM International
Published: 31 October 2011
DOI: 10.31399/asm.hb.v06a.a0005610
EISBN: 978-1-62708-174-0
..., and the introduction of closed-loop controls and diagnostic feedback systems in the EB welding systems. It reviews the beam diagnostic tools that interrogate the beam to produce a reconstruction of the power density distribution and provide additional information on the size and shape of the EB. Knowledge...
Series: ASM Handbook
Volume: 20
Publisher: ASM International
Published: 01 January 1997
DOI: 10.31399/asm.hb.v20.a0009211
EISBN: 978-1-62708-194-8
... focuses on the mechanical properties of AM-processed Ti-6Al-4V, IN-625, and IN-718. The development of closed-loop, real-time, sensing, and control systems is essential to the qualification and advancement of AM. This involves the development of coupled process-microstructural models, sensor technology...
Series: ASM Handbook
Volume: 8
Publisher: ASM International
Published: 01 January 2000
DOI: 10.31399/asm.hb.v08.a0003314
EISBN: 978-1-62708-176-4
... to accomplish closed loop control of materials testing systems in performing standard materials tests and for the development of custom testing applications. It explores the advanced software tools for materials testing. The article includes a description of baseline isothermal fatigue testing, creep-fatigue...
Series: ASM Handbook
Volume: 4C
Publisher: ASM International
Published: 09 June 2014
DOI: 10.31399/asm.hb.v04c.a0005851
EISBN: 978-1-62708-167-2
... water. Fig. 1 (a) Water recirculating system for cooling an induction power supply including stainless steel pump, copper pipe, cartridge filter, nonferrous plate-type heat exchanger, and temperature control to prevent condensation. (b) Schematic of closed-loop water cooling system...
Series: ASM Handbook
Volume: 6A
Publisher: ASM International
Published: 31 October 2011
DOI: 10.31399/asm.hb.v06a.a0005578
EISBN: 978-1-62708-174-0
... control: Machine control extends machine monitoring by implementing a closed-loop control system on one or more indirect weld parameters. Two of the more common closed-loop controllers in rotary friction welding are spindle speed control (particularly for direct-drive machine tools) and axial load...
Series: ASM Handbook
Volume: 24A
Publisher: ASM International
Published: 30 June 2023
DOI: 10.31399/asm.hb.v24A.a0006968
EISBN: 978-1-62708-439-0
... be monitored, and thereby, a closed-loop control system can be incorporated to adjust the feeding rate to reduce filament transport error, increase part density, and avoid interlayer voids ( Ref 116 ). Thus, integrating an effective online closed-loop quality-control framework that can work with the monitoring...
Series: ASM Handbook
Volume: 5A
Publisher: ASM International
Published: 01 August 2013
DOI: 10.31399/asm.hb.v05a.a0005719
EISBN: 978-1-62708-171-9
... spray controls discussed here include the open-loop input-based, open-loop output-based, closed-loop input-based, and closed-loop output-based or adaptive controls. The article discusses the common causes and practical solutions for arc starting problems. It also outlines certain important developments...
Image
Published: 09 June 2014
Fig. 1 (a) Water recirculating system for cooling an induction power supply including stainless steel pump, copper pipe, cartridge filter, nonferrous plate-type heat exchanger, and temperature control to prevent condensation. (b) Schematic of closed-loop water cooling system in (a) More
Series: ASM Handbook
Volume: 4B
Publisher: ASM International
Published: 30 September 2014
DOI: 10.31399/asm.hb.v04b.a0005931
EISBN: 978-1-62708-166-5
..., on the other hand, are closed-loop systems, where the motor sends back at least one signal (angular position) and often two (angular position and speed). Proportional-Integral-Derivative Control Today (2013), the vast majority of atmosphere-control systems use what is termed proportional-integral...
Series: ASM Handbook
Volume: 4C
Publisher: ASM International
Published: 09 June 2014
DOI: 10.31399/asm.hb.v04c.a0005852
EISBN: 978-1-62708-167-2
... for the closed-loop control (feedback to a set point) to assure that the power level requested is the power level delivered. The common modes are closed-loop control at constant voltage, constant power, or constant current. Often, for discrete part heat treating with single-shot or static heating coils...
Series: ASM Handbook
Volume: 13C
Publisher: ASM International
Published: 01 January 2006
DOI: 10.31399/asm.hb.v13c.a0004102
EISBN: 978-1-62708-184-9
...-through” from the lake or river and back again. Some power plants have a service water system consisting of a closed loop of treated water that is cooled by a raw water heat exchanger ( Fig. 3 ). This is typical of plants that utilize seawater or brackish water for cooling. Fig. 3 A closed loop...
Book: Casting
Series: ASM Handbook
Volume: 15
Publisher: ASM International
Published: 01 December 2008
DOI: 10.31399/asm.hb.v15.a0005292
EISBN: 978-1-62708-187-0
... human error and process variability. During the past 20 years, die casting process monitoring systems and closed-loop shot control systems have been developed to measure and control the injection phase and other process variables. For die casting to become a fully automated process, the die casting...
Series: ASM Handbook
Volume: 4C
Publisher: ASM International
Published: 09 June 2014
DOI: 10.31399/asm.hb.v04c.a0005846
EISBN: 978-1-62708-167-2
..., yokes, shunts, and screens for magnetic flux control in induction systems. Highly Conductive Materials for Field Reduction Highly conductive materials in the form of closed loops are commonly used in induction systems to reduce the level of magnetic fields in certain areas. The effect...
Series: ASM Handbook
Volume: 6A
Publisher: ASM International
Published: 31 October 2011
DOI: 10.31399/asm.hb.v06a.a0005559
EISBN: 978-1-62708-174-0
... on an electronic signal feedback, such as the so-called dynamic resistance of the workpiece during welding, or simply systems that maintained a constant current or voltage at the workpiece. Later systems included the ability to “close the loop” around electrode displacement and other mechanical signals as well...
Series: ASM Handbook
Volume: 24A
Publisher: ASM International
Published: 30 June 2023
DOI: 10.31399/asm.hb.v24A.a0006955
EISBN: 978-1-62708-439-0
..., are also available. Fig. 8 XY 2–100 protocol. (a) DB-25 pin layout and connector wiring. (b) Transmission timing diagram. CK, clock; SYNC, synchronization; CH, channel Although the galvo rotation control is closed-loop with encoder feedback, the laser position control is open-loop because...