1-20 of 399 Search Results for

Pumping plants

Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Series: ASM Handbook
Volume: 5B
Publisher: ASM International
Published: 30 September 2015
DOI: 10.31399/asm.hb.v05b.a0006059
EISBN: 978-1-62708-172-6
... later in this article. When the conveyed wastewater reaches pump stations, it collects in wet wells from which suction inlets to pumps are positioned. The pumps convey the wastewater to another pump station or storage facility or onward to a treatment plant. The headspace surfaces, typically cast...
Series: ASM Handbook
Volume: 4C
Publisher: ASM International
Published: 09 June 2014
DOI: 10.31399/asm.hb.v04c.a0005851
EISBN: 978-1-62708-167-2
...-loop nonferrous recirculating system to cool the power supply, heat station, coils, bus, and water-cooled leads/cables. All use some sort of water-to-water heat exchanger in conjunction with plant water (dirty water) supplied by a cooling tower, radiator/fan, refrigeration-type chillers, city water...
Series: ASM Handbook
Volume: 5B
Publisher: ASM International
Published: 30 September 2015
DOI: 10.31399/asm.hb.v05b.a0006040
EISBN: 978-1-62708-172-6
... vertical-shaft lift pumps or centrifugal pumps that convey raw water from reservoirs or holding tanks to a treatment plant through either aqueducts or large-diameter water transmission piping. The pumps are commonly coated externally but not internally. If they are coated internally, fusion-bonded epoxy...
Series: ASM Handbook
Volume: 5B
Publisher: ASM International
Published: 30 September 2015
DOI: 10.31399/asm.hb.v05b.a0006035
EISBN: 978-1-62708-172-6
... and the PWR include emergency core cooling systems. The article describes a DBA test and other coating performance parameters necessary for safety-related coating systems. It provides a detailed account of the selection criteria of coating types in a nuclear plant. The article concludes by highlighting...
Series: ASM Handbook
Volume: 13C
Publisher: ASM International
Published: 01 January 2006
DOI: 10.31399/asm.hb.v13c.a0004176
EISBN: 978-1-62708-184-9
... a chemical processing plant, considerable attention is paid to fluid flows, sizing of lines, pumps and processing equipment, and temperatures and pressures. Materials are selected on the basis of past experience, corrosion tests, corrosion literature, and the recommendations of materials suppliers...
Series: ASM Handbook
Volume: 13C
Publisher: ASM International
Published: 01 January 2006
DOI: 10.31399/asm.hb.v13c.a0004133
EISBN: 978-1-62708-184-9
... improvement over a subcritical 16.5 MPa/538 °C/538 °C plant with an efficiency of 37% (high heating value) Steam conditions Power plant examples Net percentage point increase in efficiency Net plant efficiency, % 28.4 MPa/538 °C/538 °C … 2.5 39.5 28.4 MPa/538 °C/566 °C Schwarze Pump, 1998...
Series: ASM Handbook
Volume: 13C
Publisher: ASM International
Published: 01 January 2006
DOI: 10.31399/asm.hb.v13c.a0004223
EISBN: 978-1-62708-184-9
..., that is, boiling water reactors (BWRs) and pressurized water reactors (PWRs), is necessary. Although corrosion was considered in all plant designs, corrosion was not considered as a serious problem. The major concern was general corrosion, and it was well known at the time of LWR design and construction...
Book: Casting
Series: ASM Handbook
Volume: 15
Publisher: ASM International
Published: 01 December 2008
DOI: 10.31399/asm.hb.v15.a0005350
EISBN: 978-1-62708-187-0
... an electric motor rather than an air motor. Plant air is the most expensive energy source in the plant. A small blower keeps the pump cool. Treat the Cause of Dross Buildup Treat the cause of dross buildup, not the symptom. Investigate why the furnace is generating dross. Typical reasons are: Air...
Series: ASM Handbook
Volume: 13C
Publisher: ASM International
Published: 01 January 2006
DOI: 10.31399/asm.hb.v13c.a0004102
EISBN: 978-1-62708-184-9
... condenser cooling system that condenses the main process steam for reuse in the cycle. Service water systems cool a wide range of plant components, some common to most power plants regardless of fuel type, including turbine lubricating oil coolers, generator hydrogen coolers, and pump lubricating oil...
Series: ASM Handbook
Volume: 13C
Publisher: ASM International
Published: 01 January 2006
DOI: 10.31399/asm.hb.v13c.a0004161
EISBN: 978-1-62708-184-9
... with conventional fly ash/bottom ash handling systems may be grouped into two categories: Corrosion and erosion (material deterioration) Scaling and plugging (material buildup) These problem areas must be addressed by designers of ash-handling systems and plant operators, who should consider factors...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003567
EISBN: 978-1-62708-180-1
... increase wear damage in wet and aqueous environments have been identified ( Ref 1 ). Slurry Handling The movement of materials as a slurry is an efficient means of transportation that is used in many industries. However, the movement of these slurries can cause significant corrosive wear. Pumps...
Series: ASM Handbook
Volume: 13C
Publisher: ASM International
Published: 01 January 2006
DOI: 10.31399/asm.hb.v13c.a0004137
EISBN: 978-1-62708-184-9
... and will attack most metal compounds. Fiberglass or other thermoplastics have found extensive use in wastewater plants for this reason ( Fig. 6 ). The scrubber housing, recycle pump, and related components are typically made of fiberglass using vinyl-ester resins with synthetic veils. Where critical components...
Series: ASM Handbook
Volume: 4B
Publisher: ASM International
Published: 30 September 2014
DOI: 10.31399/asm.hb.v04b.a0005923
EISBN: 978-1-62708-166-5
... Abstract Quenchant agitation can be obtained by circulating quenchant in a quench tank through pumps and impellers. The selection of the agitation method depends on the tank design, type and volume of the quenchant, part design, and the severity of quench required. This article describes flow...
Book: Casting
Series: ASM Handbook
Volume: 15
Publisher: ASM International
Published: 01 December 2008
DOI: 10.31399/asm.hb.v15.a0005285
EISBN: 978-1-62708-187-0
... implications of dross, and in-plant enhancement or recovery of dross. It discusses the influence of the melter type on dross generation and the influence of charge materials and operating practices on melt loss. Fluxing is a word applied in a broad sense to a number of melt-treating methods. The article also...
Series: ASM Handbook
Volume: 13C
Publisher: ASM International
Published: 01 January 2006
DOI: 10.31399/asm.hb.v13c.a0004153
EISBN: 978-1-62708-184-9
... Abstract This article begins with a discussion on the components and importance of flue gas desulfurization (FGD) technology used in power plant for pollution control. It further discusses the corrosion problems encountered in different operating zones of FGD system and the major forms...
Series: ASM Handbook
Volume: 2
Publisher: ASM International
Published: 01 January 1990
DOI: 10.31399/asm.hb.v02.a0001080
EISBN: 978-1-62708-162-7
... Chemical processing Storage tanks, agitators, pumps, columns, frames, screens, mixers, valves, pressurized reactors, filters, piping and tubing, heat exchangers, electrodes and anode baskets for metal and chlorine-alkali electrolysis Energy industry  Power generating plants Condensers, cooling...
Series: ASM Handbook
Volume: 13A
Publisher: ASM International
Published: 01 January 2003
DOI: 10.31399/asm.hb.v13a.a0003660
EISBN: 978-1-62708-182-5
... equipment, such as in piping, pumps, valves, and condensers. Although techniques are available commercially for on-line insertion and retrieval of test specimens, that is, without plant shutdown, they are not used routinely in all industries because of cost. Mass-Loss Tests For engineering...
Series: ASM Handbook
Volume: 18
Publisher: ASM International
Published: 31 December 2017
DOI: 10.31399/asm.hb.v18.a0006400
EISBN: 978-1-62708-192-4
... of maintenance philosophies. The article concludes with a discussion on various condition monitoring in industrial sectors, including condition-monitoring techniques in nuclear power plants, road condition monitoring, and condition monitoring in wind turbines. acoustic emission testing condition...
Series: ASM Handbook
Volume: 13C
Publisher: ASM International
Published: 01 January 2006
DOI: 10.31399/asm.hb.v13c.a0004152
EISBN: 978-1-62708-184-9
...-to-tubesheet joint heater shell IN STEAM TURBINE ELECTRICAL POWER GENERATION PLANTS, turbine exhaust steam is condensed, and the condensate is reheated for return as feedwater to the boiler. Water from the condenser to the feedwater pump is called condensate, and from the pump to the boiler...
Series: ASM Handbook
Volume: 4C
Publisher: ASM International
Published: 09 June 2014
DOI: 10.31399/asm.hb.v04c.a0005899
EISBN: 978-1-62708-167-2
...% Figure 24 shows a diagram of the furnace cooling circuit for a tandem plant. It is characterized by a 40 °C (104 °F) inlet temperature and a maximum 67 °C (152.6 °F) outlet temperature, a tank automatically filled via level probes and switchoff in case of a lack of water, a second pump to act...