Skip Nav Destination
Close Modal
Update search
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
NARROW
Format
Topics
Book Series
Date
Availability
1-4 of 4
Polarization resistance
Close
Follow your search
Access your saved searches in your account
Would you like to receive an alert when new items match your search?
Sort by
Series: ASM Handbook
Volume: 24
Publisher: ASM International
Published: 15 June 2020
DOI: 10.31399/asm.hb.v24.a0006621
EISBN: 978-1-62708-290-7
Abstract
This article focuses on a study that was performed to understand the effects of powder attributes; process parameters; and hot isostatic pressing (HIP) treatment on the densification, mechanical and corrosion properties, and microstructures of 17-4 PH stainless steel gas- and water-atomized laser-powder bed fusion (LPBF) parts at various energy densities. The results from the study showed the strong dependence of densification, mechanical properties, and microstructures on temperature, pressure, and time during the HIP cycle. The density, ultimate tensile strength, hardness and yield strength of gas and water-atomized LPBF parts increased due to HIP treatment and were higher than as-printed properties. The results also confirmed superior corrosion performance of the HIP treated LPBF parts.
Series: ASM Handbook
Volume: 23
Publisher: ASM International
Published: 01 June 2012
DOI: 10.31399/asm.hb.v23.a0005683
EISBN: 978-1-62708-198-6
Abstract
The interaction of an implant with the human body environment may result in degradation of the implant, called corrosion. This article discusses the corrosion testing of metallic implants and implant materials. The corrosion environments for medical implants are the extracellular human body fluids, very complex solutions containing electrolytes and nonelectrolytes, inorganic and organic constituents, and gases. The article describes the fundamentals of electrochemical corrosion testing and provides a brief discussion on various types of corrosion tests. It illustrates corrosion current density determination by Tafel extrapolation, potentiodynamic measurement of the polarization resistance, electrochemical impedance measurement, and potentiostatic deaeration. Tests combining corrosion and mechanical forces, such as fretting corrosion tests, environment-assisted cracking tests, and ion-leaching tests are also discussed.
Series: ASM Handbook
Volume: 13C
Publisher: ASM International
Published: 01 January 2006
DOI: 10.31399/asm.hb.v13c.a0004117
EISBN: 978-1-62708-184-9
Abstract
This article explores the use of the electrochemical and nonelectrochemical techniques for measuring the corrosion behavior of buried metals and the types of probes used. The electrical resistance technique is the main nonelectrochemical technique used for measuring corrosion rate. Electrochemical techniques discussed include linear polarization resistance, electrochemical noise, harmonic distortion analysis, electrochemical impedance spectroscopy, and hydrogen permeation. The principles of operation for the corrosion measuring techniques are described along with examples of their use in soils.
Series: ASM Handbook
Volume: 13A
Publisher: ASM International
Published: 01 January 2003
DOI: 10.31399/asm.hb.v13a.a0003659
EISBN: 978-1-62708-182-5
Abstract
This article describes the criteria for selecting a corrosion-monitoring method used in industrial plants. It provides a detailed discussion on the design, advantages, and disadvantages of plant corrosion-testing program. The basic types of racks used to support and insulate the coupons are also discussed. The analysis of electrical-resistance probes, sentry holes, side-stream loop, electrochemical noise, hydrogen-probe, and process streams are used to monitor and estimate corrosion rates. The corrosion rates can also be estimated by ultrasonic thickness measurements, polarization-resistance measurements, corrosion potential measurements, and alternating current impedance measurements. Corrosion monitoring strategies, such as locations, data analysis, redundancy, and other issues, are discussed. The article concludes with information on the interpretation and reporting of corrosion testing.