Skip Nav Destination
Close Modal
Update search
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
NARROW
Format
Topics
Book Series
Date
Availability
1-3 of 3
Carcinogenicity
Close
Follow your search
Access your saved searches in your account
Would you like to receive an alert when new items match your search?
Sort by
Series: ASM Handbook
Volume: 23
Publisher: ASM International
Published: 01 June 2012
DOI: 10.31399/asm.hb.v23.a0005665
EISBN: 978-1-62708-198-6
Abstract
This article describes the corrosion resistance and ion release from main transition metallic bearings used as medical devices. It discusses the main issues associated with the in vivo presence of ions and their biocompatibility during the exposure of patients to different aspects of ion toxicity. These include ion concentration and accumulation in organisms, reactive oxygen species and oxidative stress, and carcinogenicity stimulated by the corrosion process and toxic ions release.
Series: ASM Handbook
Volume: 23
Publisher: ASM International
Published: 01 June 2012
DOI: 10.31399/asm.hb.v23.a0005666
EISBN: 978-1-62708-198-6
Abstract
Implant debris is known to cause local inflammation, local osteolysis, and, in some cases, local and systemic hypersensitivity. The debris can be stainless steel, cobalt alloy, and titanium alloy, and soluble debris obtained due to wear from all orthopedic implants. This article addresses the biologic aspects of implant debris, both locally and systemically. It describes debris-induced local effects, particle-induced proinflammatory responses, and debris-induced systemic effects. The article concludes with a discussion on the four systemic effects of implant debris, namely, neuropathic effects, hypersensitivity effects, carcinogenicity, and general toxicity.
Series: ASM Handbook
Volume: 2
Publisher: ASM International
Published: 01 January 1990
DOI: 10.31399/asm.hb.v02.a0001119
EISBN: 978-1-62708-162-7
Abstract
Metal contamination of the environment reflects both natural sources and industrial activity, affecting human health. This article begins with a discussion on the level of metal exposure resulting in toxicological effects, the factors influencing toxicity of metals, and carcinogenicity of metal compounds. It discusses some commonly used chelating agents for treating metal intoxication, and clinical effectiveness in treating poisoning by different metals. The metals discussed are grouped into four categories: (1) major toxic metals with multiple effects, including arsenic, beryllium, cadmium, chromium, lead, mercury, and nickel; (2) essential metals with potential for toxicity, including cobalt, copper, iron, manganese, molybdenum, selenium, and zinc; (3) metals with toxicity related to medical therapy, including aluminum, bismuth, gallium, gold, lithium, and platinum; and (4) minor toxic metals, including antimony, barium, indium, magnesium, silver, tellurium, thallium, tin, titanium, uranium, and vanadium. The main factors included in the discussion are their disposition, toxicity, biological factors and treatment.