ASM Failure Analysis Case Histories: Failure Modes and Mechanisms
Failure of a Polyoxymethylene Gear Wheel
-
Published:2019
Abstract
A polyoxymethylene gear wheel that had been in operation in a boiler room failed. Investigation (visual inspection and 305x images) supported the conclusion that failure was due to postcrystallization causing considerable shrinkage. Breakdown along the crystalline superstructure started mainly at the mechanically stressed tooth flanks. In addition, oil vapors, humidity, and other degradative agents could also have contributed to the observed failure. No recommendations were made.
Sign in
ASM members
Member Sign InFailure of a Polyoxymethylene Gear Wheel, ASM Failure Analysis Case Histories: Failure Modes and Mechanisms, ASM International, 2019, https://doi.org/10.31399/asm.fach.modes.c0092103
Download citation file: