ASM Failure Analysis Case Histories: Oil and Gas Production Equipment
Storage and Handling Equipment
-
Published:2019
Abstract
A 100,000 barrel crude oil storage tank rupture caused extensive property damage in Dec 1980, in Moose Jaw, Saskatchewan. Failure was attributed to a brittle fracture that originated at a weld between a reinforcing pad and a manway nozzle. Factors that contributed to the brittle fracture included incomplete penetration in a single-bevel groove weld, poor impact properties of the hot rolled ASTM A283 low-carbon steel base material, and air temperature down to 27 C on the day of failure. Details of the analysis and results of impact testing are discussed.
Abstract
Several newly developed liquid propane gas (LPG) cylinders...
Sign in
ASM members
Member Sign InStorage and Handling Equipment, ASM Failure Analysis Case Histories: Oil and Gas Production Equipment, ASM International, 2019
Download citation file: