ASM Failure Analysis Case Histories: Buildings, Bridges, and Infrastructure
Fatigue Fracture of a Steel 8 × 19 Elevator Cable
-
Published:2019
Abstract
One of six cables on a passenger elevator was found fractured during a routine inspection. The cable is made of 16-mm steel wire rope designated 8 x 19 G Preformed Extra High Strength Special Traction Elevator Cable with fiber core. Samples of wire from the cable revealed two types of fractures: flat-type fractures were observed in 1.2 and 1 mm diam wires and cup-and-cone fractures were observed in 0.6 mm diam wires. A nick observed in the side of one of the larger wires was found to be rusted. Beach marks radiating inward, indicative of fatigue cracking, were also...