Gray Cast Irons
-
Published:2025
Abstract
This article presents fractographs that show evidence of overload and fatigue in gray cast irons. The overload failure section illustrates a fractured motor housing, valve body, and bracket with microvoid coalescence (dimpled rupture) in the metal matrix between graphite flakes. The fractographs of fatigue failures illustrate a gearbox housing with fatigue striations and pearlitic microstructure.
Gray Cast Irons, Atlas of Fractographs, Vol 12A, ASM Handbook, Edited By Craig J. Schroeder, Ronald J. Parrington, Joseph O. Maciejewski, James F. Lane, ASM International, 2025, p 1–4, https://doi.org/10.31399/asm.hb.v12a.a0007063