Handbook of Case Histories in Failure Analysis
Metallurgical Analysis to Evaluate Cracking in a 316L Grade Stainless Steel Spiral Heat Exchanger
-
Published:2019
Abstract
A spiral heat exchanger made from 316L stainless steel developed a leak after eight years of service as a condenser on a distillation tower. Examination identified the leak as being located on the cooling water side in the heat affected zone (HAZ) of a weld joining two plates. Cooling water deposits were observed in a V-shaped corner formed by the weld. A metallurgical examination identified the presence of transgranular cracks in the HAZ on the cooling water side. Analysis of the cooling water revealed the presence of chlorides. Based on the metallurgical analysis and other findings, it was determined that the cracks and associated leak were the result of chloride stress-corrosion cracking.
Thomas D. Traubert, Tim A. Jur, Metallurgical Analysis to Evaluate Cracking in a 316L Grade Stainless Steel Spiral Heat Exchanger, Handbook of Case Histories in Failure Analysis, Vol 3, Edited By Larry Berardinis, ASM International, 2019, p 152–157, https://doi.org/10.31399/asm.fach.v03.c9001773
Download citation file:
New Handbook: Volume 11B
Now available in the Digital Library! Volume 11B serves as a reference and guide to help engineers determine the causes of failure in plastic components and make corrective adjustments through design and manufacturing modifications.