Handbook of Case Histories in Failure Analysis
Corrosion Failure of Bottom Plates of an Aboveground Storage Tank
-
Published:2019
Abstract
This paper describes the investigation of a corrosion failure of bottom plates on an aboveground tank used for the storage of potable water. The tank was internally inspected for the first time after six years of service. Paint blisters and rust spots were observed on the bottom plates and first to third course shell plates. Sand blasting and repainting of the bottom plates and first course shell plates was to be used as a remedial measure. However, during the sand blasting, holes and deep pitting were observed on the bottom plates. On-site visual inspection, magnetic flux leakage (MFL) inspection,...
Sign in
ASM members
Member Sign InM. Mobin, A.U. Malik, S. Al-Fozan, F. Al-Muaili, Corrosion Failure of Bottom Plates of an Aboveground Storage Tank, Handbook of Case Histories in Failure Analysis, Vol 3, Edited By Larry Berardinis, ASM International, 2019, p 96–100, https://doi.org/10.31399/asm.fach.v03.c9001765