Handbook of Case Histories in Failure Analysis
Cracking of Inconel 800H in a Steam Methane Reformer Furnace
-
Published:1993
Abstract
During 5.7 years of service, dye penetrant inspection of Inconel 800H pigtail connections regularly showed cracks at weld toes. Weld repairs were not able to prevent reoccurrence but often aggravated the condition. Samples containing small, but detectable, reducer-to-pigtail cracks showed intergranular cracks originating at weld toes and filled with oxidation product, which precluded determination of the cracking mechanism. All weldments exhibited high degrees of secondary precipitates, with original fabrication welds exhibiting higher apparent levels than repair welds. SEM/EDS analysis showed base metal grain boundary precipitates to be primarily chromium carbides, but some titanium carbides were also observed. Failure was...
Sign in
ASM members
Member Sign InScott R. Gertler, Cracking of Inconel 800H in a Steam Methane Reformer Furnace, Handbook of Case Histories in Failure Analysis, Vol 2, Edited By Khlefa A. Esaklul, ASM International, 1993, p 168–171, https://doi.org/10.31399/asm.fach.v02.c9001328
Download citation file: