Stress-Corrosion Cracking of a Swaged Stainless Steel Reheater Pendent Tube

By
Anthony C. Studer
Anthony C. Studer
Radian Corporation
Search for other works by this author on:
;
Robert S. Dickens
Robert S. Dickens
The Hartford Steam Boiler Inspection and Insurance Company
Search for other works by this author on:
Published:
1993
Page range:
230 - 234

Abstract

A cold-formed Grade TP 304 stainless steel swaged region of a reheater tube in service for about 8000 hours cracked because of sulfur-induced stress-corrosion cracking (SCC). Cracking initiated from the external surface and a high sulfur content was detected in the outer diameter and crack deposits. Comparison of the microstructure and hardness of the swaged region and unswaged Grade TP 304 stainless steel tube metal indicated that the swaged section was not annealed to reduce the effects of cold working. The high hardness created during swaging increased the stainless steel's susceptibility to sulfur-induced SCC. Because SCC requires water to be present, cracking most likely occurred during downtime or startups. To prevent future failures, the boiler should be kept dry during downtime to avoid formation of sulfur acids, and the swaged sections of the tubes should be heat treated after swaging to reduce or eliminate strain hardening of the metal.

You do not currently have access to this content.
Don't already have an account? Register

Anthony C. Studer, Robert S. Dickens, 1993. "Stress-Corrosion Cracking of a Swaged Stainless Steel Reheater Pendent Tube", Handbook of Case Histories in Failure Analysis, Khlefa A. Esaklul

Download citation file:


Close
Close Modal
This Feature Is Available To Subscribers Only

Sign In or Create an Account

Close Modal
Close Modal