Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.bldgs.c9001219
EISBN: 978-1-62708-219-8
...Abstract Abstract During construction of a river bridge with 80 twisted cables, one or more fractures were found in each of 21 wires of 18 cables before assembly. All were located at the outside wrapping whose Z-profile wires were galvanically zinc-coated. It was suspected that hydrogen played...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.bldgs.c0047694
EISBN: 978-1-62708-219-8
...Abstract Abstract Extra high strength zinc-coated 1080 steel welded wire was wound into seven-wire cable strands for use in aerial cables and guy wires. The wires and cable strands failed tensile, elongation, and wrap tests, with wires fracturing near welds at 2.5 to 3.5% elongation and through...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.homegoods.c0048674
EISBN: 978-1-62708-222-8
... compressed to clamp onto the framework prior to springback. The heat treatment cycle of the fasteners consisted of austenitizing, quenching, tempering to obtain a tempered martensite microstructure, acid cleaning, zinc electroplating, coating with a clear dichromate and thereafter baking to remove...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0001812
EISBN: 978-1-62708-180-1
... on stress-corrosion cracking, hydrogen embrittlement, and liquid-metal embrittlement of bolts and nuts. The article explains the most commonly used protective metal coatings for ferrous metal fasteners. Zinc, cadmium, and aluminum are commonly used for such coatings. The article also illustrates...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.process.c9001215
EISBN: 978-1-62708-235-8
... alloy formation. Even in the case of steel parts with lower silicon contents the reaction between iron and zinc can continue until the pure zinc layer has been consumed entirely if the work piece is not cooled sufficiently after withdrawal. Coating defects Galvanized steels Hot dip galvanizing...
Series: ASM Failure Analysis Case Histories
Volume: 3
Publisher: ASM International
Published: 01 December 2019
DOI: 10.31399/asm.fach.v03.c9001832
EISBN: 978-1-62708-241-9
... using galvanized 1 16 in. steel sheet. Visual inspection revealed a high integrity weld. However, observation of a sharp definition of the weld across the plate thickness suggested that the weld temperature was relatively high. The zinc coating had been removed on both edges prior...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.bldgs.c9001656
EISBN: 978-1-62708-219-8
... and epoxy-coated bar. Chlorides Reinforced concrete Reinforcement bars Zinc coatings Steel reinforcing bar Corrosion fatigue Introduction Procedure and Results Conclusions Acknowledgments References References 1. Roper H. and Hetherington G. , “Fatigue Tests...
Series: ASM Failure Analysis Case Histories
Volume: 1
Publisher: ASM International
Published: 01 December 1992
DOI: 10.31399/asm.fach.v01.c9001127
EISBN: 978-1-62708-214-3
.... The fracture surfaces were coated with zinc oxide. It was concluded that the failure resulted from improper repairs and/or adjustments, including the use of a cosmetic zinc oxide cream as a lubricant. The cream initiated deterioration of the originally ductile plastic, causing it to become brittle and fragile...
Series: ASM Failure Analysis Case Histories
Volume: 2
Publisher: ASM International
Published: 01 December 1993
DOI: 10.31399/asm.fach.v02.c9001357
EISBN: 978-1-62708-215-0
..., and zinc Remedial Action Use of a fuel such as Gasoil is recommended in order to meet the operational lifetime of the turbine blades. Proper coating of the blades would improve their performance and perhaps permit the use of the less expensive Diesel C fuel. However, this type of remedial action...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.marine.c0091036
EISBN: 978-1-62708-227-3
...Abstract Abstract Socket head cap screws used in a naval application were failing in service due to delayed fracture. The standard ASTM A 574 screws were zinc plated and dichromate coated. Investigation (visual inspection, 1187 SEM images, chemical analysis, and tension testing) of both...
Series: ASM Failure Analysis Case Histories
Volume: 3
Publisher: ASM International
Published: 01 December 2019
DOI: 10.31399/asm.fach.v03.c9001766
EISBN: 978-1-62708-241-9
... weld related hydrogen cracking. Energy dispersive spectroscopy (EDS) was conducted in this region of the fracture surface, indicating a zinc coating consistent with the galvanized finish applied to the entire anchor, a representative EDS spectrum is shown in Fig. 6 . This evidence definitively...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.bldgs.c9001702
EISBN: 978-1-62708-219-8
... in) thick (equivalent to about 0.8 mm ( 1 32 in) loss of metal); steel rocker assemblies badly rusted. September 1969 - first repairs; damaged concrete removed, steel rebar sandblasted; some rebar primed with epoxy; other rebar coated with inorganic zinc coating; patch constructed; patch...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.power.c0046874
EISBN: 978-1-62708-229-7
... valves that had shot-peened and galvanized steel springs. No further failures occurred for more than four years following this action. Both the zinc coating, which provided galvanic protection for the spring, and the open-top valve construction, which allowed free circulation of air with a reduced...
Series: ASM Failure Analysis Case Histories
Volume: 3
Publisher: ASM International
Published: 01 December 2019
DOI: 10.31399/asm.fach.v03.c9001808
EISBN: 978-1-62708-241-9
... is gradually decreased by insulating corrosion products, i.e., zinc oxide, zinc carbonate, etc. It has even been reported that a slight reversal of polarity can occur, i.e., the remaining zinc coating is the cathode and the exposed steel is now the anode [ 12 ]. While the conditions of bacteria-rich river...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003549
EISBN: 978-1-62708-180-1
...: change in the environment; change in the alloy or heat treatment; change in design; use of galvanic protection; use of inhibitors; use of nonmetallic coatings and liners; application of metallic coatings; use of surface treatments, thermal spray, or other surface modifications; corrosion monitoring...
Series: ASM Failure Analysis Case Histories
Volume: 3
Publisher: ASM International
Published: 01 December 2019
DOI: 10.31399/asm.fach.v03.c9001817
EISBN: 978-1-62708-241-9
... such as decarburized layer, nonmetallic inclusions, or martensite formation. In addition, the wires were free from any sort of corrosion and pitting. Therefore, corrosion had no role in the failure of wires. This was due to the zinc coating of wires, where in the galvanic couple of iron–zinc, even a loss of a portion...
Series: ASM Handbook
Volume: 11
Publisher: ASM International
Published: 15 January 2021
DOI: 10.31399/asm.hb.v11.a0006782
EISBN: 978-1-62708-295-2
..., and the application of preventive measures. The fundamentals of corrosion are described in more detail in Ref 2 . However, as a brief introduction, the electrochemical nature of corrosion can be illustrated by the attack on zinc by hydrochloric acid (HCl). When zinc is placed in dilute hydrochloric acid, a vigorous...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.auto.c9001678
EISBN: 978-1-62708-218-1
... fatigue cracking in other bolts (A, B and C). The bolts were hardened and tempered. The microstructure consisted of tempered martensite. The microstructure showed no deformation and the zinc coating was intact indicating no sharp notch had occurred during service. The detachment of the right side...
Series: ASM Handbook
Volume: 11
Publisher: ASM International
Published: 15 January 2021
DOI: 10.31399/asm.hb.v11.a0006778
EISBN: 978-1-62708-295-2
... with beach marks • Overload zone consistent with applied loading direction • Ratchet marks where origins join • Multiple brittle-appearing fissures • External surface and internal fissures contain reaction scale coatings • Fracture after limited dimensional change Scanning electron microscopy, 20–10,000...
Book Chapter

Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003548
EISBN: 978-1-62708-180-1
... container, but becomes cathodic when the can is opened and exposed to air. Zinc is an active metal. It is susceptible to galvanic corrosion and is widely used for galvanic anodes, in cathodic protection as a sacrificial coating (for example, galvanizing or electroplating), and as a pigment in certain types...