1-20 of 60 Search Results for

water staining

Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Image
Published: 01 January 2002
Fig. 13 Light micrograph showing a very large shrinkage gap between the phenolic resin mount (PM) and a specimen of 6061-T6 aluminum etched with aqueous 0.5% hydrofluoric acid. Note the metal flow at the specimen edge (revealed using Nomarski DIC illumination) and the water stains (arrows More
Image
Published: 01 June 2019
Fig. 1 Dry tubercle and ring stains on pipe weld in the melter cooling water system. More
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.modes.c0046512
EISBN: 978-1-62708-234-1
... diffraction) supported the conclusions that leakage was the result of galvanic corrosion of the aluminum alloy spacers while in storage. The molybdenum disulfide was apparently suspended in a volatile water-containing vehicle that acted as an electrolyte between the aluminum alloy spacer and the nickel-plated...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.homegoods.c9001627
EISBN: 978-1-62708-222-8
... Abstract A section from a stainless steel kitchen sink showed a round red stain on its surface after a short time in storage. Several of these sinks were stacked together and separated by felt pads while in storage, and the mating sink showed a nearly identical stain in the same area, while...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.steel.c9001513
EISBN: 978-1-62708-232-7
..., the individual corrosion pits acted as stress raisers and initiated coarse grain spalling. Due to a bending moment on the rotating element, this in turn initiated bending fatigue normal to the longitudinal axis, which propagated through to the bore of the inner ring. Stain marks were visible in the bore...
Image
Published: 01 June 2019
Fig. 1 Power plant gate-valve stem of 17-4 PH stainless that failed by SCC in high-purity water. (a) A fracture surface of the valve stem showing stained area and cup-and-cone shearing at perimeter. 0.7×. (b) Micrograph showing secondary intergranular cracks branching from fracture surface. 50× More
Image
Published: 01 January 2002
Fig. 31 Power plant gate-valve stem of 17-4 PH stainless that failed by SCC in high-purity water. (a) A fracture surface of the valve stem showing stained area and cup-and-cone shearing at perimeter. 0.7×. (b) Micrograph showing secondary intergranular cracks branching from fracture surface More
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.power.c0091640
EISBN: 978-1-62708-229-7
... ( Fig. 1a ) in a large area where fracture had propagated along prior-austenite grain boundaries without deformation. The stains remained even after ultrasonic cleaning in a solution of detergent in hot water. Fig. 1 Power plant gate-valve stem of 17-4 PH stainless that failed by SCC in high...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.power.c9001682
EISBN: 978-1-62708-229-7
... Abstract The secondary cooling water system pressure boundary of Savannah River Site reactors includes expansion joints utilizing a thin-wall bellows. While successfully used for over thirty years, an occasional replacement has been required because of the development of small, circumferential...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.modes.c9001683
EISBN: 978-1-62708-234-1
.... All of the leaks and tubercles were located at field welds in the pipe system. Fig. 1 Dry tubercle and ring stains on pipe weld in the melter cooling water system. The inspection during this study revealed several poorly made welds that had the characteristic deposits and staining. Loss...
Series: ASM Failure Analysis Case Histories
Volume: 2
Publisher: ASM International
Published: 01 December 1993
DOI: 10.31399/asm.fach.v02.c9001329
EISBN: 978-1-62708-215-0
... Abstract Various aluminum bronze valves and fittings on the essential cooling water system at a nuclear plant were found to be leaking. The leakage was limited to small-bore socket-welded components. Four specimens were examined: three castings (an ASME SB-148 CA 952 elbow from a small-bore...
Series: ASM Failure Analysis Case Histories
Volume: 1
Publisher: ASM International
Published: 01 December 1992
DOI: 10.31399/asm.fach.v01.c9001044
EISBN: 978-1-62708-214-3
... the tube supports and shell by the high-pressure water cleaning. Figure 1 shows staining on the tubes along with heavy surface discoloration, which was blue in color. Most of this blue discoloration was later removed by chemical cleaning. Fig. 1 Condenser shell and tube support plates after...
Series: ASM Failure Analysis Case Histories
Volume: 2
Publisher: ASM International
Published: 01 December 1993
DOI: 10.31399/asm.fach.v02.c9001386
EISBN: 978-1-62708-215-0
... fracture that was preceded by a small fatigue region. Pitting corrosion was evident at the fracture origin. The areas around the load cells had been subjected to regular washdowns using high-pressure hot water, and the pitting was attributed to crevice corrosion between the load cell and the holddown bolts...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.petrol.c9001518
EISBN: 978-1-62708-228-0
... For the purposes of a comparison, the coupling from the other end of the hose was dismantled to reveal the hose underneath. It was observed that the textile braid was stained/colored a red-brown from the corrosion product of the braid wire that had penetrated out through the textile braid. The textile braid...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.power.c0046737
EISBN: 978-1-62708-229-7
... (manganese bronze). The bolts and nuts were made of copper alloy C46400 (naval brass, uninhibited). The water that was circulated through the tower had high concentrations of oxygen, carbon dioxide, and chloramines. Analysis (visual inspection, bend tests, fractographs, 50x unetched micrographs, 100x...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003532
EISBN: 978-1-62708-180-1
...% hydrofluoric acid. Note the metal flow at the specimen edge (revealed using Nomarski DIC illumination) and the water stains (arrows on the aluminum specimen). Fig. 14 Light micrograph showing stain (arrows pointing up) from the etchant (Vilella's reagent) that seeped from the shrinkage gap (wide...
Series: ASM Handbook
Volume: 11
Publisher: ASM International
Published: 15 January 2021
DOI: 10.31399/asm.hb.v11.a0006765
EISBN: 978-1-62708-295-2
... hydrofluoric acid. Nomarski differential interference contrast reveals the curvature at the edge of the specimen and water stains (arrows) along the edge of the specimen. Figure 6 shows a high-speed steel specimen in a phenolic mount, where a large shrinkage gap allowed the etchant, Vilella’s reagent...
Series: ASM Failure Analysis Case Histories
Volume: 1
Publisher: ASM International
Published: 01 December 1992
DOI: 10.31399/asm.fach.v01.c9001064
EISBN: 978-1-62708-214-3
.... All tanks were hydrotested using potable (rain) water brought in by tanker. This potable water was resident in the tanks for 3 months. Leaks in the tank walls were neither noted nor found. Areas of iridescent staining and light corrosion around welds in an accessible tank were investigated. Although...
Series: ASM Failure Analysis Case Histories
Volume: 2
Publisher: ASM International
Published: 01 December 1993
DOI: 10.31399/asm.fach.v02.c9001338
EISBN: 978-1-62708-215-0
... tubes Leakage Copper Pitting corrosion Background Copper tubes from the cooler assemblies of a large air-conditioning unit exhibited leakage upon installation of the unit. Specimen Selection Two 46 cm (18 in.) long tubes from newly installed chilled water coils were sent...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.conag.c9001634
EISBN: 978-1-62708-221-1
...: There was no covering of the wire spiral layer to prevent water ingress, which will initiate corrosion. The original rubber covering had been broken by the pressure of the ridges of the gripping “fingers” in the coupling. The area between the outer ferrule and the hose acts as a “crevice-like” region that can trap...