1-20 of 114 Search Results for

ultrasonic fatigue test

Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.bldgs.c9001135
EISBN: 978-1-62708-219-8
... the carbon content was twice what it should have been. Based on this and results of ultrasonic testing, which revealed that the banding occurred in 24-ft lengths, it was decided to close the bridge and replace the defective steel. The steel used in the construction of this bridge was specified as ASTM A441...
Series: ASM Failure Analysis Case Histories
Volume: 2
Publisher: ASM International
Published: 01 December 1993
DOI: 10.31399/asm.fach.v02.c9001300
EISBN: 978-1-62708-215-0
... be inspected carefully for signs of cracking or misalignment. Ultrasonic testing is recommended for detection of subsurface cracks, while magnetic particle testing will detect surface cracking. Visual inspection can be used to determine the teeth contact pattern. Alignment Pulverizers Rolling contact...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.design.c0089657
EISBN: 978-1-62708-233-4
... be provided for each lot. Investigation (visual inspection, fatigue testing, 0.25x/0.35x/50x magnifications, 2% nital etched 60x/65x magnifications, and SEM views) showed that most of the service fractures occurred in pistons containing vermicular graphite. Recommendations included ultrasonic testing...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.process.c0089734
EISBN: 978-1-62708-235-8
...-particle testing, radiographic inspection, and 2% nital etched 1.7x views) showed varying IDs on the assemblies and supported the conclusions that the failures of the butt welds were the result of fatigue cracks caused by cyclic thermal stresses that initiated at stress-concentrating notches at the toes...
Series: ASM Failure Analysis Case Histories
Volume: 2
Publisher: ASM International
Published: 01 December 1993
DOI: 10.31399/asm.fach.v02.c9001327
EISBN: 978-1-62708-215-0
...Abstract Abstract Three ASME SA106 grade B carbon steel feed water piping reducers from a pressurized water reactor showed indications of flaws near welds during ultrasonic testing. Further examination and testing indicated that the cracks resulted from a low-cycle corrosion fatigue phenomenon...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.conag.c9001468
EISBN: 978-1-62708-221-1
... of that resulting from torsional fatigue. Because it occurred on two different planes at 45 deg to the axis of the shaft it was due to reversals of torsional stress rather than fluctuations of unidirectional torque. Following this failure, the shafts of six other similar cranes were tested ultrasonically. Cracks...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.pulp.c0047615
EISBN: 978-1-62708-230-3
... on the inside in the area of the fin tip. Cracking at the end of the fin-to-tube fillet weld was noted. The results indicate the failures were due to corrosion fatigue whose stresses were primarily thermally induced. A temporary solution included inspecting all tubes with shear-wave ultrasonics. Tubes...
Series: ASM Failure Analysis Case Histories
Volume: 3
Publisher: ASM International
Published: 01 December 2019
DOI: 10.31399/asm.fach.v03.c9001841
EISBN: 978-1-62708-241-9
... and propagation. A nitinol stent subjected to an unintentionally long ultrasonic cleaning treatment fractured during bend testing. SEM analysis showed that striations were present on the fracture surface, indicating that a fatigue crack preceded the overload fracture as shown in Fig. 6 and 7 . Several...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.conag.c9001472
EISBN: 978-1-62708-221-1
... from the hole was evaluated initially and a progressive saw cut is then made through the hole to simulate as closely as possible a developing fatigue crack, the ultrasonic response being checked at intervals. Taking into consideration the factors which may be present during a site test...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.pulp.c9001393
EISBN: 978-1-62708-230-3
... a number of rivet holes. Fig. 8 Location of probe when ultrasonically testing for fissures at toe of seal-weld Fig. 9 Trace on cathode ray tube of ultrasonic test instrument Due to the extent and severity of the defects revealed by the ultrasonic examination it was decided...
Series: ASM Failure Analysis Case Histories
Volume: 1
Publisher: ASM International
Published: 01 December 1992
DOI: 10.31399/asm.fach.v01.c9001050
EISBN: 978-1-62708-214-3
... the shell. An ultrasonic examination of all Yankee dryers of the same type was recommended to look for cracking at the edge of the shell. Modification of the head-to-shell joint was recommended as well. Bolted joints Shells (structural forms) Class 60 Corrosion fatigue Background Visual...
Series: ASM Failure Analysis Case Histories
Volume: 3
Publisher: ASM International
Published: 01 December 2019
DOI: 10.31399/asm.fach.v03.c9001822
EISBN: 978-1-62708-241-9
... included nondestructive testing, metallography, and scanning electron microscopy. Based on the results, the failure was attributed to transit fatigue, caused during highway transportation. Cracks along the toes of the weld from both the outside and inside surfaces, the transgranular nature of cracking...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.marine.c9001511
EISBN: 978-1-62708-227-3
... of the shaft. In the case of this shaft, a solution would have been to machine the core of the shaft to remove the brittle material or to use a tubular shaft. Forgings Shafts (power) Tankers (waterborne) Ultrasonic testing Low-carbon steel Fatigue fracture An LNG tanker experienced a fracture...
Series: ASM Failure Analysis Case Histories
Volume: 1
Publisher: ASM International
Published: 01 December 1992
DOI: 10.31399/asm.fach.v01.c9001079
EISBN: 978-1-62708-214-3
...-related failures Brittle fracture Background Testing Procedure and Results Conclusion and Recommendations References References 1. “Evaluation of the Ultrasonic Data Recording and Processing System (UDRPS),” EPRI Report NP-4397, Electric Power Research Institute, Jan 1986 . 2...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.chem.c9001470
EISBN: 978-1-62708-220-4
... bar test from the eye rim, gave the following results: Several special tests were carried out in order to determine if local embrittlement of the material had taken place at the surfaces of the rivet holes. Four strips were cut from the plate to include on one side a half hole at which a fatigue...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.conag.c9001460
EISBN: 978-1-62708-221-1
... was satisfactory and, as is usual, gave no indication of the presence of internal defects. Fig. 4 Etched sections through defective welds located by ultrasonics testing. (×1). Fig. 5 Etched sections through defective welds located by ultrasonics testing. (×1). While the part-penetration...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.homegoods.c9001677
EISBN: 978-1-62708-222-8
... continuous load application until fracture occurred. A fourth strip was fatigued by bending the strip back and forth until fracture occurred. A fifth strip was heated with an oxy-acetylene torch while the material was twisted to fracture. The results from these tests were then compared with the original...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.matlhand.c9001463
EISBN: 978-1-62708-224-2
... the weld metal, fracture occurring when the remaining area of sound metal was insufficient to support the load. Fig. 1 Development of fatigue crack from internal defects. (×2). It is difficult, during normal routine testing or inspection, to detect the presence of, or to find cracks which...
Series: ASM Failure Analysis Case Histories
Volume: 2
Publisher: ASM International
Published: 01 December 1993
DOI: 10.31399/asm.fach.v02.c9001368
EISBN: 978-1-62708-215-0
... Hydroelectric generators Shafts (power) Turbines 4140 UNS G41400 Fatigue fracture Background Visual Examination of General Physical Features Testing Procedure and Results Conclusion Selected References Selected References • Wulpi D.J. , Failures of Shafts , Failure Analysis...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.modes.c9001446
EISBN: 978-1-62708-234-1
..., probably originating as a secondary pipe in the ingot which was subsequently displaced and forced into the wall of the vessel during the piercing operation. Gas cylinders Radiography Ultrasonic testing Low-alloy steel Transgranular fracture Metalworking-related failures The presence...