1-14 of 14 Search Results for

surgical simulators

Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.med.c9001606
EISBN: 978-1-62708-226-6
... of surgically implantable biomedical fixation devices to stabilize fractured bones into proper alignment for subsequent healing is a widely accepted medical practice. 1 Thousands of these devices have been inserted into human beings within the last half-century. 2 In the form of tubes, rods, or plates...
Series: ASM Failure Analysis Case Histories
Volume: 3
Publisher: ASM International
Published: 01 December 2019
DOI: 10.31399/asm.fach.v03.c9001803
EISBN: 978-1-62708-241-9
.... 23 – 30 . 2. Azevedo C.R.F. and Hippert E. Jr. : “ Failure Analysis of Surgical Implants in Brazil ,” J. Eng. Failure Analys. , 2002 , 9 , pp. 621 – 633 10.1016/S1350-6307(02)00026-2 . 3. Azevedo C.R.F. : “ Failure Analysis of a Commercially Pure Titanium Plate...
Series: ASM Handbook
Volume: 11A
Publisher: ASM International
Published: 30 August 2021
DOI: 10.31399/asm.hb.v11A.9781627083294
EISBN: 978-1-62708-329-4
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0001819
EISBN: 978-1-62708-180-1
... simulates the joint motion. Occasionally, only one joint surface, such as the femoral head, is replaced by an artificial component, which works against a natural articulation surface. Most joint replacements are performed on the hip. Because the normal femoral head is almost spherical, its motion...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003549
EISBN: 978-1-62708-180-1
... corrosion-resistant properties to a passive surface film. The naturally occurring passive film is usually enhanced with immersion in a hot nitric acid solution or steam. For example, stainless steel surgical implants develop this passive layer when the implants are sterilized in steam. The exact nature...
Series: ASM Handbook
Volume: 11B
Publisher: ASM International
Published: 15 May 2022
DOI: 10.31399/asm.hb.v11B.a0006917
EISBN: 978-1-62708-395-9
... A.M. , Modeling of Tool-Tissue Interactions for Computer-Based Surgical Simulation: A Literature Review , Presence , Vol 17 , 2008 , p 468 10.1162/pres.17.5.463 33. Tanaka E. and Eijden T.V. , Biomechanical Behavior of the Temporomandibular Joint Disk , Crit. Rev. Oral Biol...
Series: ASM Handbook
Volume: 11
Publisher: ASM International
Published: 15 January 2021
DOI: 10.31399/asm.hb.v11.a0006782
EISBN: 978-1-62708-295-2
..., stainless steel owes its corrosion-resistant properties to a passive surface film. The naturally occurring passive film is usually enhanced with immersion in a hot nitric acid solution or steam. For example, stainless steel surgical implants develop this passive layer when the implants are sterilized...
Book Chapter

Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003548
EISBN: 978-1-62708-180-1
Series: ASM Handbook
Volume: 11B
Publisher: ASM International
Published: 15 May 2022
DOI: 10.31399/asm.hb.v11B.a0006939
EISBN: 978-1-62708-395-9
..., with maximum migration observed when acetic acid was used as a food simulant ( Ref 185 ). Food packaging ZnO quantum dots in a polystyrene film or a polyvinylpyrrolidone (PVP) gel Purified colloidal ZnO quantum dots were dissolved in polystyrene and cast as films; alternatively, PVP-capped ZnO quantum...
Series: ASM Handbook
Volume: 11
Publisher: ASM International
Published: 15 January 2021
DOI: 10.31399/asm.hb.v11.a0006783
EISBN: 978-1-62708-295-2
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003500
EISBN: 978-1-62708-180-1
... may increase in frequency over time. In many cases, avoiding failures beyond a certain predetermined desired life provides no benefit, such as is the case when a surgical implant is designed to far outlive the human recipient. There is also a point of diminishing return on investments related...
Series: ASM Handbook
Volume: 11B
Publisher: ASM International
Published: 15 May 2022
DOI: 10.31399/asm.hb.v11B.a0006864
EISBN: 978-1-62708-395-9
Series: ASM Handbook
Volume: 11
Publisher: ASM International
Published: 15 January 2021
DOI: 10.31399/asm.hb.v11.a0006753
EISBN: 978-1-62708-295-2
... life provides no benefit, such as when a surgical implant is designed to far outlive the human recipient. There is also a point of diminishing return on investments related to extending the life of a component. One example is when the increasing repair costs for a car exceed its worth. A life-cycle...
Series: ASM Handbook
Volume: 11B
Publisher: ASM International
Published: 15 May 2022
DOI: 10.31399/asm.hb.v11B.9781627083959
EISBN: 978-1-62708-395-9