Series: ASM Failure Analysis Case Histories
Volume: 3
Publisher: ASM International
Published: 01 December 2019
DOI: 10.31399/asm.fach.v03.c9001833
EISBN: 978-1-62708-241-9
... material samples from the near-failure region and by thermodynamic analysis. A scanning Auger microprobe, SEM, and commercial thermodynamic software codes were used in the investigation. Results indicated that the boiler failure was caused by grain-boundary segregation of phosphorous, tin, and nitrogen...
Series: ASM Failure Analysis Case Histories
Volume: 2
Publisher: ASM International
Published: 01 December 1993
DOI: 10.31399/asm.fach.v02.c9001318
EISBN: 978-1-62708-215-0
... side. EDS analysis indicated the presence of mercury on the fracture surface and mercury was also detected using scanning auger microprobe (SAM) analysis. The mercury was accidentally introduced into the cylinders during a gas-blending operation through a contaminated blending manifold. Replacement...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.aero.c0006402
EISBN: 978-1-62708-217-4
..., H2SO4 anodized, and coated with MIL-C-27725 integral fuel tank coating on the rib side. Scanning electron microscopy and microprobe analysis (both conventional energy-dispersive and Auger analyzers) showed that the anodic coating was applied over an improperly cleaned and contaminated surface...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.power.c9001676
EISBN: 978-1-62708-229-7
...-dispersive x-ray analysis was performed using a Tracor Northern NS 880 x-ray analyzer attachment. Auger analysis was performed using a Physical Electronics 595 scanning Auger microprobe with a 5 kV electron beam. Results Varying amounts of corrosion were observed along the length of the detector...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.pulp.c0045911
EISBN: 978-1-62708-230-3
... on the apparently clean fracture areas. This was done using the scanning Auger microscope on several portions of the various fractures. The Auger spectra obtained from one fracture, as received in the laboratory and after argon ion etching for 12 min (equal to about 120 nm), showed that the entire oxide thickness...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.power.c9001004
EISBN: 978-1-62708-229-7
... temperature, FATT, curves were obtained. Small bar samples, 25mm long, 2mm × 2mm, were machined from broken charpy specimens and fractured at liquid nitrogen temperatures in a scanning auger microprobe, SAM. Ten separate grain boundaries were analysed, utilising auger spectroscopy ( 9 ) in each sample...
Series: ASM Failure Analysis Case Histories
Volume: 2
Publisher: ASM International
Published: 01 December 1993
DOI: 10.31399/asm.fach.v02.c9001335
EISBN: 978-1-62708-215-0
... elements were detected in the grain boundaries. The embrittled tube was then analyzed using an Auger electron scanning microprobe. A notched sample was fractured under ultrahigh vacuum. Tellurium and carbon, along with oxygen, copper, and nickel, were detected on much of the intergranular fracture...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003520
EISBN: 978-1-62708-180-1
... to analyze inclusions or corrodents observed on the fracture face. A more recently developed tool is the scanning Auger microprobe, which is capable of analyzing surfaces on an atomic scale. This tool is very useful in analyzing surface films and in detecting impurity segregation that causes temper...
Series: ASM Handbook
Volume: 11
Publisher: ASM International
Published: 15 January 2021
DOI: 10.31399/asm.hb.v11.a0006786
EISBN: 978-1-62708-295-2
... detected using scanning Auger microprobe analysis. The mercury was accidentally introduced into the cylinders during a gas-blending operation through a contaminated blending manifold. Replacement of the contaminated manifold was recommended, along with discontinued use of mercury manometers, the original...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003554
EISBN: 978-1-62708-180-1
... indicated that failure occurred intergranularly from the cylinder side. Energy-dispersive spectroscopy analysis indicated the presence of mercury on the fracture surface, and mercury was also detected using scanning Auger microprobe analysis. The mercury was accidentally introduced into the cylinders during...
Series: ASM Handbook
Volume: 11B
Publisher: ASM International
Published: 15 May 2022
DOI: 10.31399/asm.hb.v11B.a0006943
EISBN: 978-1-62708-395-9
... 9. Wolstenholme J. , Auger Electron Spectroscopy: Practical Application to Materials Analysis and Characterization of Surfaces, Interfaces, and Thin Films , Momentum Press , LLC, New York , 2015 , p 1 – 10 10. Goldstein J.I. et al. , Cathodoluminescence , Scanning...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.power.c9001666
EISBN: 978-1-62708-229-7
.... Fig. 13 EDXA concentration profiles within crack, transverse section. After the crack was broken open, deposits on the entire crack surface were analyzed in the SEM and, in addition, with the Auger microprobe. The results confirmed that chlorine was present on the fracture faces but only...
Series: ASM Handbook
Volume: 11
Publisher: ASM International
Published: 15 January 2021
DOI: 10.31399/asm.hb.v11.a0006759
EISBN: 978-1-62708-295-2
... be sampled to later perform chemical analysis using other methods. Electron microprobe analysis or electron probe microanalysis is an alternative to scanning electron microscopy for performing chemical analysis. Electron probe microanalysis in conjunction with WDS is considered more quantitative than...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003529
EISBN: 978-1-62708-180-1
... to the application of stress or was caused by a sustained stress. Auger analysis may be used in bigger investigations of more costly failures, to preclude embrittlement of grain boundaries by other low melting point elements, such as sulfur, antimony, tin, and phosphorus. Any of these tests would probably shed more...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003524
EISBN: 978-1-62708-180-1
... region using acetate tape softened in acetone, dried, then carefully stripped from the fracture surface. Upon return to the laboratory, the replicas may be gold coated and examined with a scanning electron microscope (SEM). Foreign particles removed from the fracture surface also may be analyzed...
Series: ASM Handbook
Volume: 11B
Publisher: ASM International
Published: 15 May 2022
DOI: 10.31399/asm.hb.v11B.9781627083959
EISBN: 978-1-62708-395-9
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003560
EISBN: 978-1-62708-180-1
Book Chapter

Series: ASM Handbook
Volume: 11
Publisher: ASM International
Published: 15 January 2021
DOI: 10.31399/asm.hb.v11.a0006790
EISBN: 978-1-62708-295-2
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003553
EISBN: 978-1-62708-180-1
... inspection had included careful scrutiny of all pipe welds by both visual and ultrasonic examination. Following discovery of the two leaks, the entire line of 150 mm (6 in.) pipe, which contained 16 welds, was carefully scanned. Five additional defects were discovered, all circumferential and all in HAZs...