Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.power.c9001480
EISBN: 978-1-62708-229-7
... intergranular penetration by molten copper. Particles of copper were seen in scale deposits on the bore of the tube. The tube in general showed a ferritic structure with partially spheroidized carbide. The fact that fusion of the copper had occurred indicated temperatures of 1100 deg C (2012 deg F) had been...
Series: ASM Failure Analysis Case Histories
Volume: 1
Publisher: ASM International
Published: 01 December 1992
DOI: 10.31399/asm.fach.v01.c9001043
EISBN: 978-1-62708-214-3
... carbide formations in a martensite matrix and outlining of prior-austenite grains by a network of fine, white lines. These features indicated that the material had been transformed by carburization by the impinging gas. The outer surface exhibited a heavy scale deposit and numerous cracks that originated...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.chem.c0091208
EISBN: 978-1-62708-220-4
... installed since start-up of the tank operation. It was noted, however, that some operational problems with the rectifier may have interrupted its protection. Investigation (visual inspection, on-site examination and testing, EDS analysis of scale deposits, and MIC testing of the soil) supported...
Series: ASM Failure Analysis Case Histories
Volume: 3
Publisher: ASM International
Published: 01 December 2019
DOI: 10.31399/asm.fach.v03.c9001826
EISBN: 978-1-62708-241-9
..., nondestructive testing, energy dispersive x-ray analysis, and inductively coupled plasma mass spectrometry. The tube was made from SA 210A1 carbon steel that had been compromised by wall thinning and the accumulation of fire and water-side scale deposits. Investigators determined that the tube failed due...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.chem.c0048702
EISBN: 978-1-62708-220-4
...Abstract Abstract An aluminum brass seawater surface condenser failed due to pitting after less than one year of service. Large pits filled with a green deposit were evidenced under the nonuniform black scale present over the entire inside surface of the tube. The black deposit was identified...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.power.c9001482
EISBN: 978-1-62708-229-7
... was filled with an oxide scale in which were embedded particles having the appearance of metallic copper. It was concluded that the cracking that occurred at the time of re-welding was due to intergranular penetration by copper present in the deposit within the tubes, which had not been completely removed...
Series: ASM Failure Analysis Case Histories
Volume: 3
Publisher: ASM International
Published: 01 December 2019
DOI: 10.31399/asm.fach.v03.c9001769
EISBN: 978-1-62708-241-9
... contribute directly to the formation of calcium carbonate, a critical factor in the buildup of scale and pitting corrosion on heat exchanger tubes. heat exchanger tubes pitting corrosion scale formation IA/PA mild steel scale deposits chemical analysis calcium concentration Mild steel (alloy...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.power.c9001651
EISBN: 978-1-62708-229-7
... occurred at the inside surfaces of the tubes. Transgranular stress-corrosion cracking, probably the result of sulphates under basic conditions, and dezincification occurred also as the result of galvanic corrosion under the deposits in the tubes. Recommendations were to use a closed-loop water system...
Series: ASM Handbook
Volume: 11A
Publisher: ASM International
Published: 30 August 2021
DOI: 10.31399/asm.hb.v11A.a0006825
EISBN: 978-1-62708-329-4
... by Sandvik AB, Sweden. (i) CR30A is a proprietary grade developed by Nippon-Kokan Steel Corporation, Japan. Heat-transfer factors and thermal conductivities of scale deposits Table 4 Heat-transfer factors and thermal conductivities of scale deposits Heat-transfer factors (a) h i...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0001816
EISBN: 978-1-62708-180-1
..., are less likely to alter either the microstructure or the characteristics of steam-side or fire-side scale, deposits, or corrosion products than is flame cutting. Mechanical methods, although generally preferred, are slow and sometimes cannot be used, because samples are inaccessible to the necessary tools...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.power.c9001396
EISBN: 978-1-62708-229-7
... be employed to detect affected tubes. Fig. 12 Massive magnetite scale on internal surface Fig. 13 Scale associated with corroded area Chemical analysis of deposits taken from tubes affected by on-load corrosion showed them to be composed of approximately 50% iron oxide (magnetite, Fe 3...
Series: ASM Handbook
Volume: 11
Publisher: ASM International
Published: 15 January 2021
DOI: 10.31399/asm.hb.v11.a0006782
EISBN: 978-1-62708-295-2
... inspection (MPI), ultrasound testing, eddy current and computed tomography (CT). Neither FPI nor MPI are recommended if scale or surface deposits are present, because the testing fluids used in the procedure would alter the original composition of the deposits. Both FPI and MPI can be performed, if required...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003549
EISBN: 978-1-62708-180-1
... is critical, softened acetate tape can be used to remove adherent deposits. This method also retains the deposits removed for further examination if necessary. If the failure analysis does not involve preservation of a fracture surface, fine sandblasting of the base metal may be useful to remove scale...
Series: ASM Failure Analysis Case Histories
Volume: 1
Publisher: ASM International
Published: 01 December 1992
DOI: 10.31399/asm.fach.v01.c9001046
EISBN: 978-1-62708-214-3
... solvent combustion incinerator. After about a year of operation, the preheater/exchanger was examined again. Holes had formed up the first 150 to 200 mm (6 to 8 in.) of the hot-side edge of the plates, causing the preheater/exchanger to short-gas. Scale deposits had also formed over large areas...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.bldgs.c9001697
EISBN: 978-1-62708-219-8
..., Florida is considered corrosive to copper pipes due to its high hardness, presence of chlorides and sulfate ions in the water, and a tendency to readily form hard water scale deposits. Copper pipes that were used below ground were not adequately protected by the specified insulation, and were...
Series: ASM Handbook
Volume: 11A
Publisher: ASM International
Published: 30 August 2021
DOI: 10.31399/asm.hb.v11A.a0006813
EISBN: 978-1-62708-329-4
..., cracks in mill scale, and local breakdown of protective films, may also initiate crevice-corrosion attack. Underdeposit corrosion often occurs as a result of scale deposition. Corrosion of this type is often associated with water that contains dissolved solids in comparatively small concentrations...
Series: ASM Failure Analysis Case Histories
Volume: 1
Publisher: ASM International
Published: 01 December 1992
DOI: 10.31399/asm.fach.v01.c9001109
EISBN: 978-1-62708-214-3
... on the grate bars because of their relatively lower temperature. When the temperature of the grate bar exceeds the melting point of the salt deposit (∼520 °C, or 970 °F), hot corrosion is activated. Because there is no inherent mechanism for salt removal other than scale spalling or surface abrasion...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003556
EISBN: 978-1-62708-180-1
... of thermophilic SRB in the severe intergranular pitting of 304L stainless steel condenser tubes in a geothermal electrical power plant operating at >100 °C (> 210 °F) has been reported ( Ref 16 ). In another example, microbiological activity and chloride concentrated under scale deposits were blamed...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.power.c9001658
EISBN: 978-1-62708-229-7
... the lower reheater inlet on a tube sample removed in 1979 for metallographic examination. Note that chromium is limited to the inner scale and there is a chromium rich band in the center of the scale. It appears that the 1979 deposit is predominantly of oxide from boiler tube surfaces. The reheater...
Series: ASM Failure Analysis Case Histories
Volume: 3
Publisher: ASM International
Published: 01 December 2019
DOI: 10.31399/asm.fach.v03.c9001834
EISBN: 978-1-62708-241-9
... specifications. Except for a khaki-colored deposit with a maximum thickness of 2.0 mm on the fireside, the outer surface of the tube was a typical brownish color and had an oxide scale with a maximum thickness of 0.2 mm ( Fig. 1 ). Obvious localised attack marked by random corrosion pits with a maximum depth...