1-20 of 99 Search Results for

quantitative microscopy

Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.power.c9001571
EISBN: 978-1-62708-229-7
... of three people hired to perform the review [ 7 ]. We concluded that the temperature estimates were reasonable and suggested that quantitative microscopy, aided by selective etching, might permit a more precise estimate of the degree of thermal exposure. Subsequently, the writer obtained the metallographic...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.steel.c9001532
EISBN: 978-1-62708-232-7
... roll quality, viz. characteristics of graphite, carbides, martensite, etc., have been extensively studied through optical microscopy, quantitative image analysis (QIA), and electron-probe microanalysis (EPMA). These are discussed in the context of spalling propensity and roll life. Hardness Hot...
Series: ASM Failure Analysis Case Histories
Volume: 3
Publisher: ASM International
Published: 01 December 2019
DOI: 10.31399/asm.fach.v03.c9001787
EISBN: 978-1-62708-241-9
... in service. Samples of the failed bit were analyzed using optical and scanning electron microscopy, quantitative metallography, and chemical analysis. The composition was found to be that of 18CrNi3Mo steel. Investigators also found evidence of inclusions and prior austenite grain size, although...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003536
EISBN: 978-1-62708-180-1
.... , Vol 21A , 1990 , p 1201 – 1207 23. Underwood E.E. , Quantitative Stereology , Addison Wesley Publishing Co. , 1970 24. DeHoff R.T. and Rhines F.N. , Quantitative Microscopy , McGraw Hill Publishing Co. , New York , 1968 25. Baddeley A.J. , Gundersen...
Series: ASM Handbook
Volume: 11
Publisher: ASM International
Published: 15 January 2021
DOI: 10.31399/asm.hb.v11.a0006759
EISBN: 978-1-62708-295-2
... be sampled to later perform chemical analysis using other methods. Electron microprobe analysis or electron probe microanalysis is an alternative to scanning electron microscopy for performing chemical analysis. Electron probe microanalysis in conjunction with WDS is considered more quantitative than...
Series: ASM Failure Analysis Case Histories
Volume: 2
Publisher: ASM International
Published: 01 December 1993
DOI: 10.31399/asm.fach.v02.c9001367
EISBN: 978-1-62708-215-0
... the inside, cooled in liquid nitrogen, and fractured open to enable analysis of a fracture surface. Standardless semi-quantitative scanning electron microscopy/energy-dispersive x-ray spectrometry (SEM/EDS) analysis revealed a high sodium content in the corrosion product ( Fig. 2 ). The base metal elements...
Series: ASM Handbook
Volume: 11
Publisher: ASM International
Published: 15 January 2021
DOI: 10.31399/asm.hb.v11.a0006770
EISBN: 978-1-62708-295-2
... for failure analysis, qualitative results are adequate, but the method can determine quantitative elemental compositions to a precision of 0.01 wt% with relative accuracies of ±5%, depending on the specific material, type of x-ray detector used, the method of data analysis employed, and, as always, the skill...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.steel.c9001535
EISBN: 978-1-62708-232-7
.... Microstructural issues influencing roll quality, such as characteristics of carbides, tempered martensite, retained austenite, etc., have been extensively studied through optical and scanning electron microscopy, electron-probe microanalysis, image analysis, and x-ray diffractometry. These are discussed...
Series: ASM Failure Analysis Case Histories
Volume: 2
Publisher: ASM International
Published: 01 December 1993
DOI: 10.31399/asm.fach.v02.c9001365
EISBN: 978-1-62708-215-0
... removed from the impeller body. The maximum defect depth is about 2.5 mm (0.10 in.). Scanning Electron Microscopy/Fractography Several areas that appeared to have the most severe surface damage were sectioned from the impeller body and fractured open in the laboratory. These surfaces were...
Series: ASM Failure Analysis Case Histories
Volume: 2
Publisher: ASM International
Published: 01 December 1993
DOI: 10.31399/asm.fach.v02.c9001324
EISBN: 978-1-62708-215-0
...) before it was fractured open in the laboratory. Fig. 2 Secondary crack after it was fractured open in the laboratory. Testing Procedure and Results Surface Examination Scanning Electron Microscopy Fractography Both primary and secondary cracks were examined using a scanning...
Series: ASM Failure Analysis Case Histories
Volume: 2
Publisher: ASM International
Published: 01 December 1993
DOI: 10.31399/asm.fach.v02.c9001281
EISBN: 978-1-62708-215-0
... segments. (a) Leading edges. (b) Trailing edges. Fig. 2 Representative leading (a) and trailing (b) edges of the nozzles. Testing Procedure and Results Surface Examination Scanning Electron Microscopy/Fractography Fig. 3 shows an area exhibiting missing coating. Examination...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.steel.c9001645
EISBN: 978-1-62708-232-7
... × 10 −9 A probe current using proprietary application software. Microprobe analysis was also performed on the polished samples in an EPMA to quantitatively determine the variation of carbon in the case and core regions, as well as to determine the types of NMI present. The EPMA studies were carried...
Series: ASM Failure Analysis Case Histories
Volume: 1
Publisher: ASM International
Published: 01 December 1992
DOI: 10.31399/asm.fach.v01.c9001072
EISBN: 978-1-62708-214-3
... and the cover. Applications The impeller was from a multistage, centrifugal unit designed to carry moist air. The unit was operated in a chemical plant. Specimen Selection Because corrosion rendered the larger crack faces useless for scanning electron microscopy (SEM) with respect to fractography...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.aero.c9001605
EISBN: 978-1-62708-217-4
... position, topology, and details of interactions with microstructural features. The aim of this investigation was to use quantitative fractography as a tool to extract information, including striation spacing and size of the stretched zone, in order to make a direct correlation with fracture mechanic...
Series: ASM Failure Analysis Case Histories
Volume: 1
Publisher: ASM International
Published: 01 December 1992
DOI: 10.31399/asm.fach.v01.c9001120
EISBN: 978-1-62708-214-3
... with striations characteristic of fatigue. Chemical Analysis/Identification A quantitative chemical analysis was conducted on the segment. The composition is shown in Table 1 . Based on the chemical analysis, the die complied with the chemical requirements for ASTM A681-89 H13 tool steel (see Table 1...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003532
EISBN: 978-1-62708-180-1
... polishing. The article also describes the microstructure examination of various materials, with emphasis on failure analysis, and concludes with information on the examination of replicas with light microscopy. References References 1. Vander Voort G.F. , Met. Eng. Q. , Vol 15 , May...
Series: ASM Failure Analysis Case Histories
Volume: 2
Publisher: ASM International
Published: 01 December 1993
DOI: 10.31399/asm.fach.v02.c9001292
EISBN: 978-1-62708-215-0
... of the struts was recommended. Crack propagation Fractography Military planes Scanning electron microscopy 7049 UNS A97049 Fatigue fracture Background A crack was detected in one arm of the right-hand horizontal brace of the nose landing gear shock strut from a large military aircraft...
Series: ASM Failure Analysis Case Histories
Volume: 1
Publisher: ASM International
Published: 01 December 1992
DOI: 10.31399/asm.fach.v01.c9001081
EISBN: 978-1-62708-214-3
..., the cracks were pried open ( Fig. 4 ). Scanning electron microscopy (SEM) of the bolt hole cracks clearly established that a low-cycle fatigue mechanism was responsible for initiating thumbnail ( Fig. 5 ) or corner-type ( Fig. 5 ) cracks. In most specimens, cracks initiated near the subsurface primary...
Series: ASM Handbook
Volume: 11B
Publisher: ASM International
Published: 15 May 2022
DOI: 10.31399/asm.hb.v11B.a0006943
EISBN: 978-1-62708-395-9
... Abstract This article discusses the operating principles, advantages, and limitations of scanning electron microscopy, atomic force microscopy, x-ray photoelectron spectroscopy, and secondary ion mass spectroscopy that are used to analyze the surface chemistry of plastics. atomic force...
Series: ASM Failure Analysis Case Histories
Volume: 3
Publisher: ASM International
Published: 01 December 2019
DOI: 10.31399/asm.fach.v03.c9001825
EISBN: 978-1-62708-241-9
... tube sections from each end of one economizer tube. One of the tube sections had leaked adjacent to the weld at the header. The microstructure and elemental composition of the tube material were consistent with type 304 stainless steel in the annealed condition. Quantitative chemical analyses were...