1-20 of 106 Search Results for

non-heat treatment

Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.machtools.c9001229
EISBN: 978-1-62708-223-5
... hydrogen cracks or fatigue cracks. The satisfactory blade from the older delivery also showed these incipient cracks ( Fig. 5 ) as well as some in the tooth base ( Fig. 2 ). All cracks were non-decarburized and were free of chromium deposits. Therefore they could not have existed before heat treatment...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.power.c9001700
EISBN: 978-1-62708-229-7
... Abstract A straight-tube cooler type heat exchanger had been in service for about ten years serving a coal pulverizer in Georgia. Non-potable cooling water from a local lake passed through the inner surfaces of the copper tubing and was cooling the hot oil that surrounded the outer diametral...
Series: ASM Failure Analysis Case Histories
Volume: 1
Publisher: ASM International
Published: 01 December 1992
DOI: 10.31399/asm.fach.v01.c9001131
EISBN: 978-1-62708-214-3
... Prevented These failures may have been prevented by non-destructive testing of the raw material prior to machining and heat treatment. Selected Reference Selected Reference • Becker W.T. and Lampman S. , Fracture Appearance and Mechanisms of Deformation and Fracture , Failure...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.modes.c9001557
EISBN: 978-1-62708-234-1
... Abstract A number of machined end frame steel forgings made of Cr-Si-Mn alloy showed tiny cracks during magnetic particle inspection after heat treatment. The cracks were mostly confined to base edges and fillet radius. No significant abnormality was observed in chemical composition...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.process.c0045988
EISBN: 978-1-62708-235-8
... that the hardness of the strap that failed was lower than the specified hardness of 30 to 35 HRC had no effect on the failure because that of the non-failed strap was even lower. Recommendation was that the strap should be heat treated as specified to maintain the required ductility and grain size. Clamps...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.process.c9001520
EISBN: 978-1-62708-235-8
...” condition required machining of heat treated material and final chrome plating. Cracking of these parts was ultimately prevented by changing the manufacturing procedure to allow for a reheat treatment, consisting of solution treatment and aging of the machined part just prior to plating. For parts...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.machtools.c0089456
EISBN: 978-1-62708-223-5
... was observed. The fracture was found to have originated near the high-stress region of the die face examination of the fracture surface. Failure of the die was concluded to have originated in an area of abnormally high hardness which is prone to microcracking during heat treatment for this grade of tool steel...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.matlhand.c9001451
EISBN: 978-1-62708-224-2
... heat treatment of certain lifting components is to rectify this dangerous condition. As the mode of failure of this hook suggested that the state of the surface might have played a major part, this aspect was investigated. The hook was sectioned transversely, in the positions indicated in Figure 2...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.power.c9001396
EISBN: 978-1-62708-229-7
...-side surface of tubes situated in zones exposed to radiant heat where high rates of heat transfer pertain. In most instances, a large number of adjacent tubes are found to have suffered, the affected zone frequently extending in a horizontal band across the boiler. In some instances, pronounced local...
Series: ASM Failure Analysis Case Histories
Volume: 3
Publisher: ASM International
Published: 01 December 2019
DOI: 10.31399/asm.fach.v03.c9001759
EISBN: 978-1-62708-241-9
.... drive shaft bearing cup brittle fracture heat treatment carbon steel shallow case endurance and load testing fracture toughness SAE-AISI 1117 (11xx resulfurized steel) UNS G11170 Introduction The automobile is a typical industrial product that involves a variety of materials...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.petrol.c9001592
EISBN: 978-1-62708-228-0
... developed to control and avoid those failures. This study presents various failure cases of sucker rods in different applications. The heat treatment of the steel material and the resulting microstructure are an important factor in the behavior of the sucker rod. A spheroidized microstructure presents...
Series: ASM Failure Analysis Case Histories
Volume: 3
Publisher: ASM International
Published: 01 December 2019
DOI: 10.31399/asm.fach.v03.c9001776
EISBN: 978-1-62708-241-9
... [ 15 ]. According to Subramanyan et al. [ 3 ], the commercial heat treatment of ASTM A128 grade B-4 steel consists of heating slowly to 1010–1090 °C followed by agitated water quenching. This produces a non-magnetic austenitic grain structure. The steel is neither tempered nor used at elevated...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.modes.c9001455
EISBN: 978-1-62708-234-1
... mechanical properties from the heat treatment given during the final stages of manufacture. This involves an initial quench (solution treatment) to produce a super-saturated solid solution followed, either by standing at room temperature (natural ageing) or by heating to a slightly elevated temperature...
Series: ASM Failure Analysis Case Histories
Volume: 3
Publisher: ASM International
Published: 01 December 2019
DOI: 10.31399/asm.fach.v03.c9001808
EISBN: 978-1-62708-241-9
... of poor operations or improper materials selection, and thus often preventable. heat exchangers drain lines corrosion bacterial growth copper stainless steel pitting perforations microscopy corrosion resistance 304L stainless steel (austenitic wrought stainless steel) UNS S30403 316L...
Series: ASM Failure Analysis Case Histories
Volume: 1
Publisher: ASM International
Published: 01 December 1992
DOI: 10.31399/asm.fach.v01.c9001061
EISBN: 978-1-62708-214-3
... of the failures. Minimizing residual stresses through use of welding procedures that include appropriate preweld and interpass temperatures and postweld stress relief heat treatment at 650 deg C (1200 deg F) was recommended to prevent further failures. Alkalies, environment Heat-affected zone Papermaking...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.aero.c9001583
EISBN: 978-1-62708-217-4
... verification, accessed overall workmanship, and measured the respective surface roughness of the rods in an effort to identify any discrepancies. Next, mechanical testing was performed, followed by optical and electron microscopy, and chemical analysis. Finally, ARL performed laboratory heat treatments...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.bldgs.c9001171
EISBN: 978-1-62708-219-8
... the precipitation (including reduction of carbon content, appropriate heat treatment, cold work of steel, reduction of austenitic grain size and stabilizing elements) were described. The presence of microcracks due to highly localized heat concentrations with consequent thermal expansion and considerable shrinkages...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.design.c9001582
EISBN: 978-1-62708-233-4
... and analysis showed that the structure and properties of the steel in the failed rods was typical of that new material and conformed to specifications. This suggested that the failures were associated with design, rather than a material or heat treatment problem. The design tolerances were therefore tightened...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.chem.c0048840
EISBN: 978-1-62708-220-4
... and caused total destruction of the vessel. Recommendation The recommendation from this analysis was to perform stress-relief heat treatments to reduce residual-stress levels after welding non-pressure retaining components to certain pressure shells. This treatment should reduce residual stresses...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.usage.c9001430
EISBN: 978-1-62708-236-5
... content of 0.6% and a tensile strength of approximately 50 t.p.s.i. and were in the normalised condition. A steel of this type is, of course, only weldable with special precautions usually requiring a high degree of pre-heat followed by slow cooling and possibly a post weld tempering treatment...