1-12 of 12 Search Results for

nitrogen liberation

Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.homegoods.c9001610
EISBN: 978-1-62708-222-8
... in the human body, including allergic reactions. The adverse reaction to the niobium jewelry could not be directly associated with the liberation of niobium ions or the residual presence of cytotoxic elements such as Co, Ni, Mo, and Cr. The poor surface finish of the niobium jewelry seems to be the only...
Book Chapter

Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003548
EISBN: 978-1-62708-180-1
... reaction is referred to as couple action, and the electrically coupled system is known as a galvanic cell. The couple consists of an anode (which liberates electrons and corrodes typically by metal dissolution and/or metal oxide formation) and a cathode (which gains electrons and typically liberates...
Series: ASM Handbook
Volume: 11A
Publisher: ASM International
Published: 30 August 2021
DOI: 10.31399/asm.hb.v11A.a0006825
EISBN: 978-1-62708-329-4
Series: ASM Handbook
Volume: 11
Publisher: ASM International
Published: 15 January 2021
DOI: 10.31399/asm.hb.v11.a0006783
EISBN: 978-1-62708-295-2
... current flows between them because of the inherent electrical potential difference between the two. The resulting reaction is referred to as couple action, and the electrically coupled system is known as a galvanic cell. The dissimilar metals/materials couple consists of an anode (which liberates...
Series: ASM Handbook
Volume: 11B
Publisher: ASM International
Published: 15 May 2022
DOI: 10.31399/asm.hb.v11B.a0006924
EISBN: 978-1-62708-395-9
... (27 °F/min) in nitrogen. Source: Ref 46 Fig. 23 Isothermal thermogravimetric analysis of thermoplastic-thermoset adhesive. Source: Ref 46 Fig. 24 Evolution of amine functionalities as a function of time during cure of an epoxy-amine system at 80 °C (175 °F). Source: Ref 47...
Series: ASM Handbook
Volume: 11
Publisher: ASM International
Published: 15 January 2021
DOI: 10.31399/asm.hb.v11.a0006785
EISBN: 978-1-62708-295-2
... ). Susceptibility to SCC is not only dependent on the intentional alloying elements but also on the presence of impurities, even in trace amounts. The effect of interstitial elements (boron, oxygen, nitrogen, carbon, and hydrogen) on the susceptibility of metals to SCC is illustrated by the behavior of austenitic...
Book Chapter

Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003562
EISBN: 978-1-62708-180-1
... are discussed in greater detail in the section “Mechanism of Fretting Wear” in this article. Fig. 15 Plot of fretting wear versus number of cycles for mild steel with 90 μm (0.0036 in.) slip amplitude in both dry air and nitrogen atmospheres. Source: Ref 24 Fig. 16 Relation between initial...
Series: ASM Handbook
Volume: 11B
Publisher: ASM International
Published: 15 May 2022
DOI: 10.31399/asm.hb.v11B.9781627083959
EISBN: 978-1-62708-395-9
Series: ASM Handbook
Volume: 11B
Publisher: ASM International
Published: 15 May 2022
DOI: 10.31399/asm.hb.v11B.a0006925
EISBN: 978-1-62708-395-9
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003525
EISBN: 978-1-62708-180-1
... depending on the nature of the sample and the experiment. The normal operating temperature range for DSC testing is −180 to 700 °C (−290 to 1290 °F), with a standard heating rate of 10 °C/min (18 °F/min). A dynamic purge gas is used to flush the sample chamber. Nitrogen is the most commonly used purge gas...
Series: ASM Handbook
Volume: 11
Publisher: ASM International
Published: 15 January 2021
DOI: 10.31399/asm.hb.v11.a0006829
EISBN: 978-1-62708-295-2
... is the basement of the Archard and related friction energy wear approaches. Fig. 20 Fretting wear weight loss versus fretting cycles for mild steel under gross slip 90 μm displacement amplitude in both dry air and nitrogen atmosphere. Adapted from Ref 74 The second basement of the Archard wear...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003556
EISBN: 978-1-62708-180-1
... steel piping used to transport a slurry of magnesium hydroxide and alumina at pH 10.5 ( Ref 17 ). Whatever the environmental conditions, microorganisms need water, a source of energy to drive their metabolism, and nutrients to provide essential building materials (carbon, nitrogen, phosphorus, trace...