1-20 of 30 Search Results for

medical applications

Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Series: ASM Failure Analysis Case Histories
Volume: 3
Publisher: ASM International
Published: 01 December 2019
DOI: 10.31399/asm.fach.v03.c9001802
EISBN: 978-1-62708-241-9
... • James B.A. , Medical Device Failure Analysis , Materials for Medical Devices , Vol 23 , ASM Handbook , Narayan R.J. , Ed., ASM International , 2012 , p 343 – 359 . 10.31399/asm.hb.v23.a0005657 • Hodgson D.E. , Wu M.H. and Biermann R.J. , Shape Memory Alloys...
Series: ASM Handbook
Volume: 11A
Publisher: ASM International
Published: 30 August 2021
DOI: 10.31399/asm.hb.v11A.a0006836
EISBN: 978-1-62708-329-4
... , Handbook of Case Histories in Failure Analysis , Vol 3 , ASM International , 2019 10.31399/asm.fach.v03.c9001841 12. James B. , Foulds J. , Eiselstein L. , Failure Analysis of NiTi Wires Used in Medical Applications , Handbook of Case Histories in Failure Analysis , Vol 3...
Series: ASM Handbook
Volume: 11A
Publisher: ASM International
Published: 30 August 2021
DOI: 10.31399/asm.hb.v11A.a0006811
EISBN: 978-1-62708-329-4
... ( Toronto ), 1996 , p 865 32. Hoeppner D.W. and Chandrasekaran V. , Characterizing the Fretting Fatigue Behavior of Ti-6Al-4V in Modular Joints , Medical Applications of Titanium and Its Alloys: The Material and Biological Issues , STP 1272, American Society for Testing and Materials...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.med.c9001606
EISBN: 978-1-62708-226-6
... for a mechanical device and should not be tolerated in a medical application where the comfort and well-being of an injured human is at issue. Would simply a material change prevent fatigue failures of the type observed in these fixation devices? Of course, it can never be predicted with absolute certainty...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.med.c9001690
EISBN: 978-1-62708-226-6
... on Nitinol has shifted to its superelastic behavior, and there are several applications in the medical device industries, including hip implants, bone spacers, bone staples, bone anchors, skull plates, vascular and nonvascular stents, and medical guidewires. 29 , 30 Nitinol alloys contain...
Series: ASM Handbook
Volume: 11A
Publisher: ASM International
Published: 30 August 2021
DOI: 10.31399/asm.hb.v11A.a0006832
EISBN: 978-1-62708-329-4
.... The topics covered are admissibility of expert opinions, how to evaluate data, factual evidence, mandatory and voluntary standards, physical evidence, medical records, scientific literature, design decisions evaluation, environment of use, user's contribution, reports of opposing experts, report of findings...
Series: ASM Failure Analysis Case Histories
Volume: 3
Publisher: ASM International
Published: 01 December 2019
DOI: 10.31399/asm.fach.v03.c9001803
EISBN: 978-1-62708-241-9
.... , Hdeib A. and Khan F.R. , Applications of Medical Implant Materials , Materials for Medical Devices , Vol 23 , ASM Handbook , Narayan R.J. , Ed., ASM International , 2012 , p 18 – 35 . 10.31399/asm.hb.v23.a0005660 This study investigated implants made of titanium alloy...
Series: ASM Failure Analysis Case Histories
Volume: 3
Publisher: ASM International
Published: 01 December 2019
DOI: 10.31399/asm.fach.v03.c9001805
EISBN: 978-1-62708-241-9
...Abstract Abstract Several surgical tool failures were analyzed to understand why they occur and how to prevent them. The study included drills, catheters, and needles subjected to the rigors of biomedical applications such as corrosive environments, high stresses, sterilization, and improper...
Series: ASM Handbook
Volume: 11A
Publisher: ASM International
Published: 30 August 2021
DOI: 10.31399/asm.hb.v11A.9781627083294
EISBN: 978-1-62708-329-4
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.homegoods.c9001610
EISBN: 978-1-62708-222-8
... Dimethylgyoxime Test Goes Detecting Release of Nickel from Earrings,” Sci. Total Environ. , 1998 , 224 , pp. 161 – 5 . 7. Anon : in Implants for Surgery - Metallic Materials - Parts 1–12 , International Organization for Standardization , ISO 5832-1 to ISO 5832-12, Geneve . 8. Anon : Medical...
Series: ASM Handbook
Volume: 11
Publisher: ASM International
Published: 15 January 2021
DOI: 10.31399/asm.hb.v11.a0006769
EISBN: 978-1-62708-295-2
..., and the application of SEM in fractography is discussed. The article covers the failure mechanisms of ductile failure, brittle failure, mixed-mode failure, and fatigue failure. Lastly, image dependence on microscope type and operating parameters is also discussed. fractography microstructure sample...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.modes.c9001593
EISBN: 978-1-62708-234-1
..., medical components, and fluid handling. 1 The polysulfone body of the failed sensor had been injection molded around a tubular stainless steel insert to form the final component. Background information obtained on the application showed that the part was routinely exposed to alternating hot and cold...
Series: ASM Handbook
Volume: 11A
Publisher: ASM International
Published: 30 August 2021
DOI: 10.31399/asm.hb.v11A.a0006838
EISBN: 978-1-62708-329-4
... of production and tooling applications. Metal AM processes also proliferated in the early 2000s, especially in the aerospace and medical industries, where tailored, low-volume, high-performance parts are required. This article gives an overview on metal AM processes and describes sources of failures...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003523
EISBN: 978-1-62708-180-1
... to be responding to accidents should be made aware of the necessity of documentation and preservation of the accident scene. There are numerous reasons, both intentional and unintentional, why the condition of the accident scene may change after an accident: Medical Attention to Injured Persons...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003539
EISBN: 978-1-62708-180-1
...), initiation processes may occupy a significant portion or majority of the overall time (duration) of the fatigue process. Final Fracture Final fracture does not occur by a fatigue mechanism at all but is simply fracture caused by the last load application, resulting in complete separation. This final...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003550
EISBN: 978-1-62708-180-1
... of this effect in the polyvinyl chloride (PVC) industry. The PVC can be altered from the rigid material from which plastic pressure pipes are made to the extremely soft, flexible material from which medical tubing is made through the judicious use of plasticizers ( Ref 6 ). However, the plasticization effect...
Series: ASM Handbook
Volume: 11
Publisher: ASM International
Published: 15 January 2021
DOI: 10.31399/asm.hb.v11.a0006772
EISBN: 978-1-62708-295-2
... and unintentional, why the condition of the accident scene may change after an accident: Medical attention to injured persons: Persons who may be injured during the accident usually become the top priority of personnel responding to the accident. However, during this process, relocation and/or alteration...
Series: ASM Handbook
Volume: 11
Publisher: ASM International
Published: 15 January 2021
DOI: 10.31399/asm.hb.v11.a0006776
EISBN: 978-1-62708-295-2
... steel tested in rotating bending. No distinct fatigue striations could be resolved. Crack growth direction from right to left Fig. 39 Crystallographic fatigue in fracture mechanics specimen of cast Co-Cr-Mo-C medical implant alloy. Scanning electron microscope views located (a) 0.025 mm (0.001...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0001819
EISBN: 978-1-62708-180-1
...), pins, and orthopedic wire are available (intramedullary refers to use of the marrow space of the bone for support). Some implants have very specific uses; others have a wide range of applications with different functions. Under the impact of a trauma, bones can fracture in any configuration...
Series: ASM Handbook
Volume: 11
Publisher: ASM International
Published: 15 January 2021
DOI: 10.31399/asm.hb.v11.a0006782
EISBN: 978-1-62708-295-2
...- and corrosion-related failures of metals and nonmetals. References References 1. “ International Measures of Prevention, Application and Economics of Corrosion Technology (IMPACT) ,” NACE International , 2016 2. Corrosion: Fundamentals, Testing, and Protection , Vol 13A , ASM Handbook ASM...