1-20 of 132 Search Results for

light optical microscopy

Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.aero.c9001717
EISBN: 978-1-62708-217-4
... to visual inspection/light optical microscopy, metallography, electron microscopy, energy dispersive spectroscopy, chemical analysis, and mechanical testing. It was observed that the vacuum cadmium coating adjacent to the fracture plane had worn off and corroded in service, thus allowing pitting corrosion...
Series: ASM Failure Analysis Case Histories
Volume: 3
Publisher: ASM International
Published: 01 December 2019
DOI: 10.31399/asm.fach.v03.c9001819
EISBN: 978-1-62708-241-9
... macroscopic overview of the fracture surface on the pump axis. Fracture origin indicated Abstract The shafts on two centrifugal pumps failed during use in a petroleum refinery. Light optical microscopy and scanning electron microscopy were used to analyze the damaged materials to determine the cause...
Image
Published: 01 June 2019
Fig. 3 Intergranular morphology observed within primary crack using light optical microscopy. Mag. 30× More
Series: ASM Failure Analysis Case Histories
Volume: 1
Publisher: ASM International
Published: 01 December 1992
DOI: 10.31399/asm.fach.v01.c9001036
EISBN: 978-1-62708-214-3
... Abstract A 1984 Chevrolet Blazer was being pushed by three youths after it ran out of gas when it was hit from behind by a 1979 Mercury Cougar. One of the youths was crushed between the two vehicles and killed. Optical microscopy was used to examine the tungsten filaments from the headlamps...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.modes.c0006440
EISBN: 978-1-62708-234-1
... due to compressive/shearing stresses Investigation Samples were analyzed with light optical and scanning electron microscopy. Portions of the mirror were sent out for analysis of the base material and visually identified corrosion products. A portion of the middle layer from area...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003527
EISBN: 978-1-62708-180-1
... the option of lighting from only one side of the failed component, to better reveal fracture surface details. Fiber Optic Lighting Fiber-optic techniques are useful in directing light to a certain location, including cavities and hollow areas, as well as providing a means to emphasize fracture surface...
Series: ASM Handbook
Volume: 11
Publisher: ASM International
Published: 15 January 2021
DOI: 10.31399/asm.hb.v11.a0006763
EISBN: 978-1-62708-295-2
... stereomicroscopic image of exemplar crankshaft fracture with light-emitting diode ring light illumination Fig. 24 Optical stereomicroscopic image of exemplar crankshaft fracture with light-emitting diode ring light illumination and high dynamic range image processing Digital Microscopy...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003542
EISBN: 978-1-62708-180-1
... begin with the unaided eye and may include various types of microscopy: light microscopy, scanning electron microscopy (SEM), transmission electron microscopy, atomic force microscopy, and other specialized methods. The bulk of the observations by far are done with low-magnification optical microscopy...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.petrol.c9001586
EISBN: 978-1-62708-228-0
.... Examination included optical and scanning electron microscopy of the fracture surfaces and metallographic examination of cross sections through the fracture surface. From the outer to inner edge of the fracture surface, three different areas were observed. Fracture features in area 1 were obliterated...
Series: ASM Handbook
Volume: 11B
Publisher: ASM International
Published: 15 May 2022
DOI: 10.31399/asm.hb.v11B.a0006851
EISBN: 978-1-62708-395-9
... is the use of an incandescent or LED fiber optic light source, such as the one shown in Fig. 16 . The resulting fracture surface image is high in contrast, and the fracture surface topography detail is maximized, as shown in Fig. 17 and 18 . The former figure shows the exemplar crankshaft fatigue...
Series: ASM Failure Analysis Case Histories
Volume: 3
Publisher: ASM International
Published: 01 December 2019
DOI: 10.31399/asm.fach.v03.c9001839
EISBN: 978-1-62708-241-9
... Austenite (γ) 1100 0.12 0.48 1.90 Austenite (γ) 900 0.23 0.92 3.70 Ferrite (α) 900 0.58 2.33 9.30 Ferrite (α) 700 1.83 7.30 29.2 Ferrite (α) 500 10.4 41.6 166.5 Fig. 3 Light optical micrographs of polished, unetched coil sample No. 1 showing branched and discrete...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.aero.c9001583
EISBN: 978-1-62708-217-4
... curve tangent to the flanks. Visual Examination/Light Optical Microscopy Each of the six failed tie rods sent to ARL were subjected to visual examination and light optical microscopy. A typical failed tie rod is shown in Fig. 1 in the as-received condition. It was observed that all six...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003532
EISBN: 978-1-62708-180-1
... polishing. The article also describes the microstructure examination of various materials, with emphasis on failure analysis, and concludes with information on the examination of replicas with light microscopy. References References 1. Vander Voort G.F. , Met. Eng. Q. , Vol 15 , May...
Series: ASM Failure Analysis Case Histories
Volume: 1
Publisher: ASM International
Published: 01 December 1992
DOI: 10.31399/asm.fach.v01.c9001102
EISBN: 978-1-62708-214-3
... Abstract Four cadmium-plated ASTM A193 grade B studs from a steam line connector associated with a power turbine failed unexpectedly in a nil-ductility manner. Fracture surfaces were covered with a light-colored, lustrous deposit. Optical microscope, SEM, and EDS analyses were conducted...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.modes.c9001628
EISBN: 978-1-62708-234-1
..., the OD of the cylinder was exposed to liquid ammonia refrigerant containing lubricant from the compressor. The lubricant (mineral oil) was intended to separate from the ammonia and be recirculated through the compressor. Nondestructive portable optical microscopy, XRF, EDS, and XPS analyses showed...
Series: ASM Failure Analysis Case Histories
Volume: 3
Publisher: ASM International
Published: 01 December 2019
DOI: 10.31399/asm.fach.v03.c9001767
EISBN: 978-1-62708-241-9
... in service for more than 30 years. Remnants of the fractured brackets were analyzed using optical and scanning electron microscopy, Fourier transform infrared spectroscopy (FTIR), and thermogravimetric analysis (TGA). The exterior surfaces of all six brackets were alike and shared similar features, including...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.auto.c9001543
EISBN: 978-1-62708-218-1
... by visual inspection, hardness traverses, radiography, dye penetrant inspection, chemical analysis, macrometallography, optical microscopy, and electron microscopy. The crown of one piston had a rough, crumbly deposit, which was detachable with a knife. Two pistons had remains of carbonaceous deposits...
Series: ASM Failure Analysis Case Histories
Volume: 2
Publisher: ASM International
Published: 01 December 1993
DOI: 10.31399/asm.fach.v02.c9001292
EISBN: 978-1-62708-215-0
... an optical microscopy and digital counter. These markings were of a regular nature and consisted of an initial heavy mark (initial touchdown) followed by a series of light, irregularly spaced marks (aircraft ground-roll). These patterns were visible on numerous areas in the fatigue region ( Fig. 5...
Series: ASM Handbook
Volume: 11
Publisher: ASM International
Published: 15 January 2021
DOI: 10.31399/asm.hb.v11.a0006765
EISBN: 978-1-62708-295-2
.... The influence of microstructures on the failure of a material is discussed and examples of such work are given to illustrate the value of light microscopy. In addition, information on heat-treatment-related failures, fabrication-/machining-related failures, and service failures is provided, with examples...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.process.c9001613
EISBN: 978-1-62708-235-8
... ). This indicates that the threaded portion of the screw was carburized. These findings were confirmed by hardness measurements at various regions of the screw. Fig. 7 Optical micrographs of the cup portion showing (a) tempered martensite in the case region, (a) tempered martensite and some ferrite (light...