1-20 of 37 Search Results for

eddy current inspection

Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.chem.c0060104
EISBN: 978-1-62708-220-4
... Abstract Eddy current inspection was performed on a vertical evaporator unit (that contained 180 tubes) used in a chemical processing plant. It was advised that the tube material was type 316 stainless steel. The shell-side fluid was condensate and gaseous methylene chloride, while the tube...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.bldgs.c0091699
EISBN: 978-1-62708-219-8
... Abstract Eddy-current inspection was performed on a leaking absorber bundle in an absorption air-conditioning unit. The inspection revealed crack-like indications in approximately 50% of the tubes. The tube material was phosphorus-deoxidized copper. Investigation (visual inspection, chemical...
Series: ASM Handbook
Volume: 11
Publisher: ASM International
Published: 15 January 2021
DOI: 10.31399/asm.hb.v11.a0006764
EISBN: 978-1-62708-295-2
... of detecting surface discontinuities by magnetic-particle inspection, liquid penetrant inspection, and eddy-current testing. The major NDE methods for internal (volumetric) inspection in failure analysis also are described. eddy-current testing liquid penetrant inspection magnetic-particle inspection...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.aero.c0047165
EISBN: 978-1-62708-217-4
... eddy-current testing. The flange on the second wheel half failed after only 31 landings, when about 46 cm (18 in.) of the flange broke off as the aircraft was taxiing. Stains on the fracture surfaces were used to determine when cracking was initiated. The analysis (visual inspection, liquid penetrant...
Series: ASM Handbook
Volume: 11
Publisher: ASM International
Published: 15 January 2021
DOI: 10.31399/asm.hb.v11.a0006758
EISBN: 978-1-62708-295-2
..., to investigate more detailed information into the volume of the component. NDE techniques such as eddy current testing (ET) for electrically-conductive materials, full volumetric inspection using ultrasonic testing (UT) for metals, and radiographic testing (RT) are available in these instances. Eddy current...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003515
EISBN: 978-1-62708-180-1
... to understand how safe and reliable that equipment or structure might be over this additional time of service. Common Measurement Techniques Many measurement techniques are employed in NDE. Those most widely used are visual, liquid penetrant, magnetic particle, eddy current, ultrasonic, and radiographic...
Series: ASM Failure Analysis Case Histories
Volume: 1
Publisher: ASM International
Published: 01 December 1992
DOI: 10.31399/asm.fach.v01.c9001027
EISBN: 978-1-62708-214-3
... was damaged, moisture ingress to the region was precluded. It was also recommended that the bushing bores be inspected for corrosion damage whenever the pillow-blocks were removed from the yoke assembly. A simple eddy current technique was recommended for inspection of the bushing bores at intervals of 300 h...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003516
EISBN: 978-1-62708-180-1
... components eddy current, ultrasonic, x-ray, dye-penetrant, and visual inspections are regularly accomplished. Fatigue Crack Growth Variables The fundamental variables involved in any life assessment are those that describe the effects and interaction of material behavior, geometry, and stress history...
Series: ASM Failure Analysis Case Histories
Volume: 1
Publisher: ASM International
Published: 01 December 1992
DOI: 10.31399/asm.fach.v01.c9001048
EISBN: 978-1-62708-214-3
... examined in detail. The tubes had been manufactured by the seamless process as per ASTM A-213 under third-party inspection. They were within the dimensional tolerances and passed chemical, physical, hydrostatic, eddy current, and intergranular corrosion tests. In a nitrogenous fertilizer plant, hot...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003524
EISBN: 978-1-62708-180-1
...: magnetic-particle inspection of ferrous metals, liquid-penetrant inspection, ultrasonic inspection, and sometimes eddy-current inspection. All these tests are used to detect surface cracks and discontinuities. Radiography is used mainly for internal examination. A photographic record of the results...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.power.c9001725
EISBN: 978-1-62708-229-7
..., referred to as “end bells” in England and Canada (and in the sketch, Fig. 1 ), are often made of a nonmagnetic alloy to minimize eddy currents and heating therefrom, thus improving the efficiency of the generator. After the accident the inboard field retaining ring was found securely in place on the rotor...
Series: ASM Failure Analysis Case Histories
Volume: 2
Publisher: ASM International
Published: 01 December 1993
DOI: 10.31399/asm.fach.v02.c9001356
EISBN: 978-1-62708-215-0
... years of other austenitic rings have been reported, representing approximately one failure per ten thousand machine-years of service. The failed ring had been inspected 18 months prior to the failure using visual, liquid penetrant and eddy current examination. No defects were found in the area...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.aero.c9001707
EISBN: 978-1-62708-217-4
...) was not able to reveal these cracks. However, eddy current inspection did detect the existence of large cracks which coincided with the indications found by MPI. Some internal cracks, which were not detected by MPI, were subsequently found during metallographic examination. MPI of the other shrink link...
Series: ASM Handbook
Volume: 11
Publisher: ASM International
Published: 15 January 2021
DOI: 10.31399/asm.hb.v11.a0006785
EISBN: 978-1-62708-295-2
... was encountered in copper alloys, caustic embrittlement was experienced in boilers. (Caustic embrittlement is also known as caustic cracking. Both of these terms are considered archaic; currently, the term caustic stress-corrosion cracking is used to describe the same phenomenon.) Cracking was observed around...
Series: ASM Handbook
Volume: 11A
Publisher: ASM International
Published: 30 August 2021
DOI: 10.31399/asm.hb.v11A.a0006808
EISBN: 978-1-62708-329-4
.... The most widely used inspection methods in the welding industry are visual, liquid penetrant, magnetic particle, radiographic, ultrasonic, acoustic emission, eddy current, and the electric current perturbation technique. Each of these methods and techniques (within each method) has its own specific...
Series: ASM Handbook
Volume: 11A
Publisher: ASM International
Published: 30 August 2021
DOI: 10.31399/asm.hb.v11A.a0006812
EISBN: 978-1-62708-329-4
... or external inspections and basis for current inspection schedules. Codes and standards used in the United States that could impact or be useful to a failure investigation include: Construction codes: ASME Section I—Power Boilers ASME Section VIII—Boiler and Pressure Vessel Code ASME Section V...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0001817
EISBN: 978-1-62708-180-1
... of pipe or tubing strive to minimize or eliminate latent surface or subsurface imperfections produced during manufacture. Nondestructive inspection, such as by eddy-current, ultrasonic, air-under-water, and hydrostatic tests, is used to detect these imperfections. Each test has its limitations...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003553
EISBN: 978-1-62708-180-1
... environments at tensile stresses well below the yield strength of the metal. The failures often take the form of fine cracks that penetrate deeply into the metal, with little or no evidence of corrosion on the nearby surface or distortion of the surrounding structure. Therefore during casual inspection...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003512
EISBN: 978-1-62708-180-1
... Abstract This article provides an overview of the structural design process and discusses the life-limiting factors, including material defects, fabrication practices, and stress. It details the role of a failure investigator in performing nondestructive inspection. The article provides...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003549
EISBN: 978-1-62708-180-1
... treatment system used in a manufacturing facility. Within six months of start-up, leaks were discovered. On-Site Examination A series of tests were performed on site to eliminate stray currents as a possible cause of failure in the piping system. The piping system was inspected for possible sources...