1-20 of 24 Search Results for

UNS S31603

Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.bldgs.c0091201
EISBN: 978-1-62708-219-8
... Abstract Type 316L (UNS S31603) austenitic stainless steel piping was installed as part of a storm-sewer treatment collection system in a manufacturing facility. Within six months of start-up, leaks were discovered. Investigation (on-site current flow testing, visual inspection, water tests...
Series: ASM Failure Analysis Case Histories
Volume: 1
Publisher: ASM International
Published: 01 December 1992
DOI: 10.31399/asm.fach.v01.c9001070
EISBN: 978-1-62708-214-3
... the corrosion to an acceptable limit. Chemical processing equipment Sulfuric acid, environment UNS S31603 UNS N08020 316L 20Cb Uniform corrosion Reference 1. Kiefer G.C. and Renshaw W.G. , The Behavior of the Chromium-Nickel Stainless Steels in Sulfuric Acid...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.med.c0048413
EISBN: 978-1-62708-226-6
... surface during cyclic loading were observed. The material was showed by the deformation structure to be in the cold-worked condition and was termed to not be the cause of the implant failure. Cyclic loads Slip bands Surgical implants 316L UNS S31603 Fatigue fracture Figure 1(a) shows a...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.pulp.c9001567
EISBN: 978-1-62708-230-3
... treatment following fabrication and welding. Chlorides Evaporators Heat exchangers Paper machines 316L UNS S31603 Stress-corrosion cracking The falling film black liquor evaporator consisted of flat twin plate heat exchangers and were employed in several effects to increase the black liquor...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.petrol.c0047606
EISBN: 978-1-62708-228-0
... after welding, the substitution of a more corrosion-resistant alloy, such as Incoloy 800 or 825, may be necessary. Activation Butt welds Pipes Residual stress Weld metal 316L UNS S31603 Stress-corrosion cracking Pitting corrosion Joining-related failures Type 316L stainless steel...
Series: ASM Failure Analysis Case Histories
Volume: 2
Publisher: ASM International
Published: 01 December 1993
DOI: 10.31399/asm.fach.v02.c9001326
EISBN: 978-1-62708-215-0
... components Pinhole Thermocouples 316L UNS S31603 (Other, general, or unspecified) corrosion Reference 1. Kiessling R. and Lange N. , Nonmetallic Inclusions in Steels, Part II , The Metals Society , London , 1978 , p 82 – 84 Selected Reference • Forms...
Series: ASM Failure Analysis Case Histories
Volume: 2
Publisher: ASM International
Published: 01 December 1993
DOI: 10.31399/asm.fach.v02.c9001264
EISBN: 978-1-62708-215-0
.... Manufacturers should never attempt to salvage this type of critical device by welding or any other procedure that might compromise its integrity. Repair welding Surgical implants 316L UNS S31603 Fatigue fracture Joining-related failures Selected Reference • Pohler O.E.M...
Series: ASM Failure Analysis Case Histories
Volume: 2
Publisher: ASM International
Published: 01 December 1993
DOI: 10.31399/asm.fach.v02.c9001350
EISBN: 978-1-62708-215-0
... that occurs in service due to vibration of the nozzles during filling and draining of the tank. Breeder reactors Crack propagation Fast nuclear reactors Storage tanks, design 316L UNS S31603 Fatigue fracture Selected Reference • Fatigue Failures, Failure Analysis...
Series: ASM Failure Analysis Case Histories
Volume: 1
Publisher: ASM International
Published: 01 December 1992
DOI: 10.31399/asm.fach.v01.c9001097
EISBN: 978-1-62708-214-3
... loading. Use of a steel with a higher molybdenum content (317L) in the annealed condition was recommended. Biomedical material 316L UNS S31603 Pitting corrosion Fatigue fracture Selected References • Pohler O.E.M. , Failures of Metallic Orthopedic Implants...
Series: ASM Failure Analysis Case Histories
Volume: 1
Publisher: ASM International
Published: 01 December 1992
DOI: 10.31399/asm.fach.v01.c9001034
EISBN: 978-1-62708-214-3
... station and implementation of bacteria control measures (a special drying process after washing and use of a sanitizing rinse) were recommended. Bacterial corrosion Tanks, corrosion Trucks 316L UNS S31603 Biological corrosion Pitting corrosion Selected Reference...
Series: ASM Failure Analysis Case Histories
Volume: 3
Publisher: ASM International
Published: 01 December 2019
DOI: 10.31399/asm.fach.v03.c9001841
EISBN: 978-1-62708-241-9
... fracture ultrasonic vibration damage stainless steel nitinol striations beach marks SEM analysis natural frequency 316L (austenitic wrought stainless steel) UNS S31603 nitinol (nickel-titanium shape memory alloy) UNS N01555 References 1. Mallette L.A...
Series: ASM Failure Analysis Case Histories
Volume: 3
Publisher: ASM International
Published: 01 December 2019
DOI: 10.31399/asm.fach.v03.c9001808
EISBN: 978-1-62708-241-9
... 316L stainless steel (austenitic wrought stainless steel) UNS S31603 References 1. Borenstein S.W. : Microbiologically Influenced Corrosion Handbook . Industrial Press ( 1994 ) 10.1533/9781845698621 . 2. Borenstein S.W. , Lindsay P.B...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.med.c9001579
EISBN: 978-1-62708-226-6
... under unilateral bending. The bending loads were presumably a consequence of leg oscillation during assisted perambulation. Inclusion 316L UNS S31603 Corrosion fatigue Exposure by orthopaedic implants to the biomechanical and biochemical forces and interactions between the implants and the...
Series: ASM Failure Analysis Case Histories
Volume: 1
Publisher: ASM International
Published: 01 December 1992
DOI: 10.31399/asm.fach.v01.c9001075
EISBN: 978-1-62708-214-3
... fracture was caused by fatigue originating at corrosion pits on the surface of the wire. It was recommended that higher-molybdenum steel in the annealed condition be used to combat pitting corrosion. Papermaking 316L UNS S31603 Fatigue fracture Pitting corrosion References...
Series: ASM Failure Analysis Case Histories
Volume: 3
Publisher: ASM International
Published: 01 December 2019
DOI: 10.31399/asm.fach.v03.c9001773
EISBN: 978-1-62708-241-9
..., it was determined that the cracks and associated leak were the result of chloride stress-corrosion cracking. spiral heat exchanger corrosion chloride contamination stainless steel transgranular cracks chemical analysis residual stress 316L (austenitic wrought stainless steel) UNS S31603...
Series: ASM Failure Analysis Case Histories
Volume: 3
Publisher: ASM International
Published: 01 December 2019
DOI: 10.31399/asm.fach.v03.c9001803
EISBN: 978-1-62708-241-9
.... orthopedic implant devices fracture corrosion inclusions and stress gaps medical materials cracking fretting pitting fractography fracture toughness Ti6Al4V (titanium-aluminum-vanadium alloy) UNS R56406 316L stainless steel (austenitic wrought stainless steel) UNS S31603...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.process.c9001647
EISBN: 978-1-62708-235-8
... trace the root cause of the porosity to the geometric conditions of the weld joint and establish corrective actions to minimize such porosity. GTAW Porosity 316L UNS S31603 Joining-related failures References 1. Cannell G. , Daugherty W. , Gaston L...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.med.c9001664
EISBN: 978-1-62708-226-6
... screws Plastic deformation Surgical implants 316L UNS S31603 Fatigue fracture Corrosion fatigue In fractures of and around the head of the femur, a compression hip screw surgical implant is sometimes employed to provide bone alignment and fixation during healing. Figure 1 shows schematically...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.med.c9001690
EISBN: 978-1-62708-226-6
.... Corrosion Fracture mechanisms Metallic surgical implants Retrieval analysis Ti-6Al-4V UNS R56406 316L UNS S31603 ISO 5832-2 grade 1 Nitinol (Other, general, or unspecified) corrosion (Other, general, or unspecified) fracture Worldwide data indicate that approximately 100 million metallic...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003569
EISBN: 978-1-62708-180-1
... of UNS S31603 Stainless Steel, Part II: Cavitation Erosion Characteristics , Mater. Sci. Eng. , Vol A290 , 2000 , p 74 – 88 10.1016/S0921-5093(00)00930-8 43. Kwok C.T. , Cheng F.T. , and Man H.C. , Cavitation Erosion and Pitting Corrosion of Laser Surface Melted Stainless...