... trucks Loads (forces) Pinions 4817 UNS G48170 4820 UNS G48200 Fatigue fracture A spiral bevel set that failed in service was submitted for an evaluation. Background Information Field Application Field application: This was the main driving set in the differential housing of a large...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.modes.c9001503
EISBN: 978-1-62708-234-1
... of failure was insufficient surface hardness, resulting from improper heat treatment. A service recall for the remaining pinions was immediately initiated. Hardness Heat treatment Hypoid gears Railroad cars Trains 4820 UNS G48200 Abrasive wear The hypoid pinion shown in Fig. 1 was placed...