Series: ASM Failure Analysis Case Histories
Volume: 2
Publisher: ASM International
Published: 01 December 1993
DOI: 10.31399/asm.fach.v02.c9001381
EISBN: 978-1-62708-215-0
... inclusions UNS G43406 Ductile fracture Background During assembly, a helicopter main rotor made of AISI E4340 steel failed while being torqued. The torque being applied reached approximately 100 N . m (900 lbf . in.) when the pitch horn bolt sheared and shot across the hangar. No other bolts were...