... decomposition 60-40-18 UNS F32800 Thermal fatigue fracture (Other, general, or unspecified) distortion High-temperature corrosion and oxidation ...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.matlhand.c0047312
EISBN: 978-1-62708-224-2
... F32800 Ductile fracture Two ductile iron T-hooks were submitted for evaluation. One of the hooks ( Fig. 1 ) was reported to have fractured in service. It was further reported that the hook had been subjected to a load that did not exceed 5900 kg (13,000 lb) at the time of fracture. No information...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.matlhand.c0047312
EISBN: 978-1-62708-224-2
... F32800 Ductile fracture Two ductile iron T-hooks were submitted for evaluation. One of the hooks ( Fig. 1 ) was reported to have fractured in service. It was further reported that the hook had been subjected to a load that did not exceed 5900 kg (13,000 lb) at the time of fracture. No information...